Objective: To explore the potential of ultrasonic modulation of plateau-potential generating subthalamic nucleus neurons (STN), by modeling their interaction with continuous and pulsed ultrasonic waves. Methods: A computational model for ultrasonic stimulation of the STN is created by combining the Otsuka-model with the bilayer sonophore model. The neuronal response to continuous and pulsed ultrasonic waves is computed in parallel for a range of frequencies, duty cycles, pulse repetition frequencies, and intensities. Results: Ultrasonic intensity in continuous-wave stimulation determines the firing pattern of the STN. Three observed spiking modes in order of increasing intensity are low frequency spiking, high frequency spiking with significant spike-frequency and spike-amplitude adaptation, and a silenced mode. Continuous-wave stimulation has little capability to manipulate the saturated spiking rate in the high frequency spiking mode. In contrast, STN firing rates induced by pulsed ultrasound insonication will saturate to the pulse repetition frequency with short latencies, for sufficiently large intensity and repetition frequency. Conclusion: Computational results show that the activity of plateau-potential generating subthalamic nucleus neurons can be modulated by selection of the stimulus parameters. Low intensities result in repetitive firing, while higher intensities silence the STN. Pulsed ultrasonic stimulation results in a shorter saturation latency and is able to modulate spiking rates. Significance: Stimulation or suppresion of the STN is important in the treatment of Parkinson's disease, e.g., in deep brain stimulation. This explorative study on ultrasonic modulation of the STN, could be a step in the direction of minimally invasive alternatives to conventional deep brain stimulation.
24 February 2018 in Medical & Biological Engineering & Computing
Objective . To design a computationally efficient model for ultrasonic neuromodulation (UNMOD) of morphologically realistic multi-compartmental neurons based on intramembrane cavitation. Approach . A Spatially Extended Neuronal Intramembrane Cavitation model that accurately predicts observed fast Charge Oscillations (SECONIC) is designed. A regular spiking cortical Hodgkin-Huxley type nanoscale neuron model of the bilayer sonophore and surrounding proteins is used. The accuracy and computational efficiency of SECONIC is compared with the Neuronal Intramembrane Cavitation Excitation (NICE) and multiScale Optimized model of Neuronal Intramembrane Cavitation (SONIC). Main results . Membrane charge redistribution between different compartments should be taken into account via fourier series analysis in an accurate multi-compartmental UNMOD-model. Approximating charge and voltage traces with the harmonic term and first two overtones results in reasonable goodness-of-fit, except for high ultrasonic pressure (adjusted R-squared ≥0.61). Taking into account the first eight overtones results in a very good fourier series fit (adjusted R-squared ≥0.96) up to 600 kPa. Next, the dependency of effective voltage and rate parameters on charge oscillations is investigated. The two-tone SECONIC-model is one to two orders of magnitude faster than the NICE-model and demonstrates accurate results for ultrasonic pressure up to 100 kPa. Significance . Up to now, the underlying mechanism of UNMOD is not well understood. Here, the extension of the bilayer sonophore model to spatially extended neurons via the design of a multi-compartmental UNMOD-model, will result in more detailed predictions that can be used to validate or falsify this tentative mechanism. Furthermore, a multi-compartmental model for UNMOD is required for neural engineering studies that couple finite difference time domain simulations with neuronal models. Here, we propose the SECONIC-model, extending the SONIC-model by taking into account charge redistribution between compartments.
Motor responses evoked by transcranial magnetic stimulation (TMS) using posterior-anterior (PA) and anterior-posterior (AP) current directions have distinct latencies and thresholds. However, the underlying reasons for these differences remain unclear. To quantify the differences in activation sites between PA- and AP-TMS. Motor evoked potentials (MEPs) were recorded from five hand and arm muscles in nine healthy participants using both PA- and AP-TMS. Active motor thresholds were determined at 11 magnetic coil positions on the scalp. Probabilistic modelling was used to combine the measured threshold data with calculated electric field data from individual MRI-based models. This approach constructed 70 probability distributions of the activation site, dependent on the muscle and TMS direction. Modelling indicated that both PA- and AP-TMS more likely activated structures in white matter than in grey matter. PA-TMS activation sites were primarily in the white or grey matter in the precentral gyrus, while the AP-TMS activations were deeper and more posterior and lateral, likely within white matter under the postcentral and/or precentral gyri. Tractography and biophysical axon models provided a potential explanation on the location of activation sites: AP-TMS may activate the bends of white matter axons farther from M1 than PA-TMS, such that the conduction velocity along the neural tract could potentially explain the longer MEP latency of AP-TMS. The differences in activation sites among the five hand and arm muscles were small. While a direct experimental confirmation of the activation sites is still needed, the results suggest that electric field analysis combined with tractography and biophysical axon modelling could be a useful computational tool for analysing and optimizing TMS.
20 March 2020 in IEEE Transactions on Biomedical Engineering
Objective: Excitation of myelinated nerve fibers is investigated by means of numerical simulations, for the application of percutaneous auricular vagus nerve stimulation (pVNS). High sensitivity to axon diameter is of interest regarding the goal of targeting thicker fibers. Methods: Excitation and blocking thresholds for different pulse types, phase durations, axon depths, axon-electrode distances, temperatures and axon diameters are investigated. The used model consists of a 50 mm long axon and a centrally located needle electrode in a layered medium representing the auricle. Neuronal excitation is simulated using the Frankenhaeuser-Huxley equations for all combinations of parameter values. Results and conclusion: Multiple modes and locations of excitation along the axon were observed, depending on the pulse type and amplitude. When increasing the axon-electrode distance from 1 mm to 2 mm, sensitivity of thresholds to axon depth decreased with ca. 50%, while sensitivity to axon-electrode distance, axon diameter and phase duration each increased with ca. 15% to 20%, except from monophasic anodal pulses, showing a 45% decrease for axon-electrode distance. These trends for axon diameter and axon-electrode distance allow for more selective stimulation of thicker target fibers using monophasic anodal pulses at higher axon-electrode distances. Cathodal monophasic pulses did not perform well due to blocking of the thicker fibers, which was only rarely seen for other pulse types. Significance: Sensitivities of stimulation thresholds to these parameters by numerical simulation reveal how the stimulation parameters can be changed in order to increase therapeutic effect and comfort during pVNS by enabling more selective stimulation.