Katherine Kokmanian

Katherine Kokmanian

Auto-generated profile, based on publicly available information

Katherine Kokmanian

Institute of Fluid Mechanics and Aerodynamics, Bundeswehr University Munich, Neubiberg, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2020 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
KSKonstantinos Steiros
Konstantinos Steiros
KKK. Kokmanian
K. Kokmanian
NBN. Bempedelis
N. Bempedelis
MHM. Hultmark
M. Hultmark
It is well known that perforation of a flat plate reduces its drag when exposed to a flow. However, studies have shown an opposite effect in the case of cylinders. Such a counterintuitive result can have significant consequences on the momentum modelling often used for wind turbine performance predictions, where increased porosity is intrinsically linked to lower drag. Here, a study of the drag of various types of porous cylinders, bars and plates under steady laminar inflow is presented. It is shown that, for most cases, the drag decreases with increased porosity. Only special types of perforations can increase the drag on both cylinders and bars, either by enhancing the effect of the rear half of the models or by organizing the wake structures. These rare occurrences are not relevant to wind turbine modelling, which indicates that current momentum models exhibit the qualitatively correct behaviour.

9 September 2019 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
KKK. Kokmanian
K. Kokmanian
SSS. Scharnowski
S. Scharnowski
MBM. Bross
M. Bross
SDS. Duvvuri
S. Duvvuri
MFM. K. Fu
M. K. Fu
MHM. Hultmark
M. Hultmark

23 March 2021 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
KHKelly Y Huang
Kelly Y Huang
CBC. E. Brunner
C. E. Brunner
MFM. K. Fu
M. K. Fu
KKK. Kokmanian
K. Kokmanian
TMT. J. Morrison
T. J. Morrison
MHMarcus Hultmark
Marcus Hultmark

1 November 2019 in Combustion and Flame
Verified
Journal Article
Closed access
ANAlex G. Novoselov
Alex G. Novoselov
CRChristopher B. Reuter
Christopher B. Reuter
OYOmar R. Yehia
Omar R. Yehia
SWSang Hee Won
Sang Hee Won
MFMatthew K. Fu
Matthew K. Fu
MMMichael Mueller
Michael Mueller

1 April 2021 in Soft Robotics
Verified
Journal Article
Open access
JSJohan Sundin
Johan Sundin
KKKatherine Kokmanian
Katherine Kokmanian
MFMatthew K. Fu
Matthew K. Fu
SBShervin Bagheri
Shervin Bagheri
MHMarcus Hultmark
Marcus Hultmark
To control and navigate micro air vehicles (MAVs) efficiently, there is a need for small, lightweight, durable, sensitive, fast, and low-power airspeed sensors. When designing sensors to meet these requirements, soft materials are promising alternatives to more traditional materials due to the large deformations they can withstand. In this article, a new concept of a soft material flow sensor is presented based on elastic filament velocimetry, which fulfills all necessary criteria. This technique measures flow velocity by relating it to the strain of a soft ribbon suspended between two static supports and subjected to a flow of interest. The ribbon is manufactured from polydimethylsiloxane and can be made piezoresistive by the addition of silver nanowires. With the described manufacturing method, the sensor can be made using common laboratory tools, outside of a clean room, significantly reducing its complexity. Furthermore, it can be operated using a simple and lightweight circuit, making it a convenient alternative for MAVs. Using a piezoresistive material allows for the flow velocity to be calibrated to the resistance change of the strained ribbon. Although certain challenges remain unsolved, such as polymer creep, the sensor has demonstrated its ability to measure flow velocities down to 4 m/s in air through experiments. A time-dependent analytical model is also provided. The model shows that the current sensor has a bandwidth of 480 Hz. Most importantly, the sensitivity and the bandwidth of the sensor can be varied strictly by modifying the geometry and the material properties of the ribbon.

23 July 2021 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
KKKatherine Kokmanian
Katherine Kokmanian
DBDiogo C. Barros
Diogo C. Barros
MHMarcus Hultmark
Marcus Hultmark
PDPierre Dupont
Pierre Dupont