Yaqiong Niu

Yaqiong Niu

Auto-generated profile, based on publicly available information

Yaqiong Niu

School of Information Science and Technology, ShanghaiTech University, Shanghai, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YWYutong Wei
Yutong Wei
LCLongsheng Cheng
Longsheng Cheng
YNYaqiong Niu
Yaqiong Niu
SCSitong Chen
Sitong Chen
CYChaofeng Ye
Chaofeng Ye
For a spin-exchange relaxation free (SERF) optically pumped magnetometer (OPM) that obtains its best performance in a zero magnetic field, an operation environment with approximately zero magnetic field is desired. This paper proposes a nested magnetic field compensation system for a magnetic shielding room (MSR) to suppress the magnetic field. Two sets of coils, one set located outside of the MSR and the other one placed inside of the MSR are combined in the system. The magnetic fields outside of the MSR are measured by tunneling magnetoresistance (TMR) sensors, while the fields inside the MSR are monitored by SERF OPMs. The two kinds of sensors complement each other in terms of measurement range and sensitivity. A nested two-stage proportional-integral (PI) closed-loop control strategy is employed to compensate for the magnetic field inside the MSR. The control parameters are regulated by the magnitude of the magnetic field to take advantage of the two kinds of sensors. The effect of the proposed system is experimentally tested. The three-axis field fluctuations are reduced by 97.52%, 98%, and 98.64% by the proposed method, respectively. The proposed method is compared with a conventional two-stage series PI control system. The x-axis magnetic field fluctuations of the conventional PI control system and the proposed system are 75.81 pT and 11.71 pT, respectively. The magnetic fluctuation of the proposed system is about 15.5% of the fluctuation of the conventional PI system. To validate the feasibility of the proposed magnetic field compensation system for ultra-weak bio-magnetic field measurement, magnetocardiography (MCG) and magnetoencephalography (MEG) signals are measured.

2 August 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YNYaqiong Niu
Yaqiong Niu
CYChaofeng Ye
Chaofeng Ye
The most efficient way of improving the sensitivity of an OPM is to maximize the spin-polarization lifetime, which requires the miniaturization of the magnetic field around the sensor. This paper proposed a novel method of compensation the magnetic field for a compact spin-exchange-relaxation-free (SERF) optically pumped magnetometer (OPM). The method employs modulation and low-frequency sweeping magnetic fields along the two directions that perpendicular to the laser beam simultaneously. The output signal of the photodiode is demodulated at different frequencies, resulting in an output signal correlated to the x-axis modulation ( β x ) and an output signal correlated to the y-axis modulation ( β y ). Then, the three components of the magnetic field are adjusted until β x and β y become sinusoids with zero bias. The proposed method can monitor the magnetic fields of the three axes simultaneously and does not require iterate during the process, which increases the speed of magnetic field compensation. The feasibility of the proposed method is demonstrated experimentally. The experiment results show that the magnetic field compensation resolutions of the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pT, respectively. The noise density of the compact OPM is about 20 fT / Hz 1/2 .

3 March 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YNYaqiong Niu
Yaqiong Niu
LCLongsheng Cheng
Longsheng Cheng
XHXingshen Hou
Xingshen Hou
CYChaofeng Ye
Chaofeng Ye
Optically pumped magnetometers (OPMs) operating in the spin-exchange relaxation-free (SERF) regime achieve excellent sensitivity in environments with zero magnetic field. Therefore, it is essential to suppress the environment magnetic field. As the environment magnetic field is not constant, it is necessary to compensate the magnetic field dynamically. This paper presents a method of compensation the environment magnetic field dynamically for array OPMs based on real-time signal separation. The OPMs serves as the signal measurement sensors, as well as the quasi-static environment magnetic field monitoring sensors. The OPMs are placed orthogonal to each other to monitor the three components of the magnetic field. The output signals are separated and reconstructed using fast wavelet transform. The low-frequency component is utilized to calculate the compensation current and the high-frequency component is recorded as the measurement result. This method does not require any additional sensors for magnetic field compensation, resulting in simplified setting and low-cost. The experimental results show that the method can suppress the quasi-static magnetic field fluctuations to less than one percent in real time. The magnetic field fluctuation is controlled within 10 pT, 10 pT and 1 pT for the three axes. For array sensors, the effect of the magnetic field gradient can be reduced by utilizing internal coils in each OPM. The magnetic signal of a human heart is measured that verifies the feasibility of the method for ultra-weak biomagnetic field measurement.

13 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
JCJieya Chen
Jieya Chen
CYChaofeng Ye
Chaofeng Ye
XHXingshen Hou
Xingshen Hou
YNYaqiong Niu
Yaqiong Niu
LSLimin Sun
Limin Sun
Optically pumped magnetometers (OPMs) functioning in the spin-exchange relaxation-free (SERF) regime have emerged as attractive options for measuring weak magnetic fields, owing to their portability and remarkable sensitivity. The operation of SERF-OPM critically relies on the ambient magnetic field; thus, a magnetic field compensation device is commonly employed to mitigate the ambient magnetic field to near zero. Nonetheless, the bias of the OPM may influence the compensation impact, a subject that remains unexamined. This paper introduced an innovative bias calibration technique for OPMs. The sensitivity of the OPM was altered by adjusting the cell temperature. The output of the OPM was then documented with varying sensitivity. It is assumed that the signal exhibits a linear correlation with the environmental magnetic field, and the statistical characteristics of the magnetic field are identical for both measurements, upon which the bias of the OPM is assessed. The bias was subsequently considered in the feedback magnetic field compensation mechanism. The results indicate that this technique might successfully reduce environmental magnetic fluctuations and enhance the sensitivity of the OPM. This technique measured the magnetic field produced by the human heart, confirming the viability of the ultra-weak biomagnetic field measurement approach.

30 April 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YNYaqiong Niu
Yaqiong Niu
SCSitong Chen
Sitong Chen
LCLongsheng Cheng
Longsheng Cheng
CYChaofeng Ye
Chaofeng Ye
Optically pumped magnetometers (OPMs) operating in the spin-exchange relaxation-free (SERF) regime require near-zero magnetic environment (<1 nT) to preserve high sensitivity; yet, current compensation techniques encounter difficulties with multi-axis crosstalk in array topologies. This paper presents a methodology for measuring and adjusting three-axis magnetic fields to mitigate magnetic interference of array OPMs. The approach utilizes a scanning magnetic field generated by embedded coils to measure the surrounding magnetic field. A cross-coupling magnetic field compensation method is proposed to suppress cross-axis coupling in the OPM array. The compensation currents are calculated by linearly fitting a feature of the sensor's output signal to the ambient magnetic field. The efficacy of this strategy is validated through theoretical derivation and experimental verification. The experimental results demonstrate that this approach achieves a magnetic field compensation resolution of 20 pT. The method enables rapid and precise magnetic field adjustment for OPM arrays, laying the groundwork for their application in bio magnetic detection.

3 November 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XHXingshen Hou
Xingshen Hou
CYChaofeng Ye
Chaofeng Ye
YNYaqiong Niu
Yaqiong Niu
JLJinjie Liu
Jinjie Liu
Optically pumped magnetometers (OPMs) offer outstanding sensitivity without requiring cryogenic cooling, enabling the creation of compact and cost-effective biomagnetic measurement systems. OPMs can be organized in high-density arrays and incorporated with wireless communication, enabling high-resolution measurements, and remote clinical applications. However, current OPM arrays predominantly rely on wired configurations, which constrains the deployment flexibility and scalability. This article presents and evaluates a wireless sensor network (WSN) utilizing Wi-Fi technology for array OPMs, offering substantial capacity that enables real-time data collection at elevated sample rates across 256 channels. A modular hardware platform has been developed, which employs a transmission jitter mechanism, wherein each data packet is dispatched at a randomized interval between 9 and 11 ms, therefore disrupting the periodicity of the transmission rhythm to eliminate the pseudo-periodic disturbances in the frequency domain. The architecture facilitates seamless scalability, allowing for the integration of more sensor nodes into the system by connecting them to the same Wi-Fi network, without necessitating modifications to the host infrastructure. Remote access and multiuser collaboration are facilitated, allowing for flexible deployment and dispersed experimental supervision. The feasibility of the system was validated via a three-channel magnetocardiography (MCG) experiment and a 256 channel simulation, demonstrating zero packet loss, a mean latency of 8.81 ms, and jitter of 0.61 ms at a 1 kHz sampling rate. The proposed WSN for array OPMs not only streamlines experimental configurations and sensor maintenance, but also provides a scalable foundation for future wearable OPM systems and distributed quantum sensing platforms.