13 February 2023 in IEEE Transactions on Instrumentation and Measurement
For a spin-exchange relaxation free (SERF) optically pumped magnetometer (OPM) that obtains its best performance in a zero magnetic field, an operation environment with approximately zero magnetic field is desired. This paper proposes a nested magnetic field compensation system for a magnetic shielding room (MSR) to suppress the magnetic field. Two sets of coils, one set located outside of the MSR and the other one placed inside of the MSR are combined in the system. The magnetic fields outside of the MSR are measured by tunneling magnetoresistance (TMR) sensors, while the fields inside the MSR are monitored by SERF OPMs. The two kinds of sensors complement each other in terms of measurement range and sensitivity. A nested two-stage proportional-integral (PI) closed-loop control strategy is employed to compensate for the magnetic field inside the MSR. The control parameters are regulated by the magnitude of the magnetic field to take advantage of the two kinds of sensors. The effect of the proposed system is experimentally tested. The three-axis field fluctuations are reduced by 97.52%, 98%, and 98.64% by the proposed method, respectively. The proposed method is compared with a conventional two-stage series PI control system. The x-axis magnetic field fluctuations of the conventional PI control system and the proposed system are 75.81 pT and 11.71 pT, respectively. The magnetic fluctuation of the proposed system is about 15.5% of the fluctuation of the conventional PI system. To validate the feasibility of the proposed magnetic field compensation system for ultra-weak bio-magnetic field measurement, magnetocardiography (MCG) and magnetoencephalography (MEG) signals are measured.
18 February 2022 in IEEE Transactions on Instrumentation and Measurement
Current sensors based on the fluxgate magnetic field meter and feedback zero-field operating principle have excellent current measurement accuracy and linearity in a large range of up to thousands of amperes. An excitation current (Ie) is employed in a magnetic fluxgate sensor to magnetize the magnetic core periodically, which will generate magnetization distortion that affects the performance of the sensor. This paper proposes a novel scheme for suppressing the magnetization distortion through an electrical compensation. The source of the magnetization distortion is theoretically derived and analyzed. It is found that the magnetization distortion is a function of the excitation current Ie and is not affected by the primary current. Since Ie is a periodical current that is determined by the parameters of the sensor itself, it is feasible to inject a specified periodical current to the output port of the sensor to cancel the magnetization distortion. Compared with the magnetization distortion compensation method with an additional core and coil, this method does not need to pair the cores or coils, which significantly reduces the complexity of the production process and saves space for the sensor. A prototype sensor with electrical compensation is designed, fabricated and tested. Experimental results show that the compensation setting significantly suppresses the magnetization distortion signal. The amplitude of the basic frequency component is reduced from 24 μV to 6.8 μV. The other odd harmonics of the magnetization distortion are also reduced. The electrical compensation method works properly in a large current range from -1.5 kA to 1.5 kA. The scale accuracy of the prototype sensor is less than 5.7 ppm (parts per million). The compensation method can suppress the magnetization distortion to a similar level with operating temperature changes from room temperature to 50 °C.
1 September 2024 in Physiological Measurement
Objective. The measurement of electromyography (EMG) signals with needle electrodes is widely used in clinical settings for diagnosing neuromuscular diseases. Patients experience pain during needle EMG testing. It is significant to develop alternative diagnostic modalities. Approach. This paper proposes a portable magnetomyography (MMG) measurement system for neuromuscular disease auxiliary diagnosis. Firstly, the design and operating principle of the system are introduced. The feasibility of using the system for auxiliary diagnosis of neuromuscular diseases is then studied. The magnetic signals and needle EMG signals of thirty subjects were collected and compared. Main results. It is found that the amplitude of muscle magnetic field signal increases during mild muscle contraction, and the signal magnitudes of the patients are smaller than those of normal subjects. The diseased muscles tested in the experiment can be distinguished from the normal muscles based on the signal amplitude, using a threshold value of 6 pT. The MMG diagnosis results align well with the needle EMG diagnosis. In addition, the MMG measurement indicates that there is a persistence of spontaneous activity in the diseased muscle. Significance. The experimental results demonstrate that it is feasible to auxiliary diagnose neuromuscular diseases using the portable MMG system, which offers the advantages of non-contact and painless measurements. After more in-depth, systematic, and quantitative research, the portable MMG could potentially be used for auxiliary diagnosis of neuromuscular diseases. The clinical trial registration number is ChiCTR2200067116.
21 April 2026 in IEEE Transactions on Industrial Electronics
Magnetocardiography (MCG) is critical for early diagnosis and treatment of cardiac diseases. Arrayed SERF atomic magnetometers deliver high-quality MCG in a near-zero field provided by a magnetic shielding cylinder (MSC) with active magnetic compensation (AMC). However, the magnetic noise within the MSC is dynamic and gradient-distributed, making conventional single-stage uniform-field AMC inadequate. To overcome this, we propose a two-stage synergistic compensation method. It flattens the gradient along the MSC opening axis in the first stage and nulls the noise along the SERF sensitivity axis at the second stage. The feedback-sensor positions are optimized by an NSGA-II based multiobjective algorithm, enhancing the noise suppression at each stage while preserving cardiac signals and avoids complex decoupling calculations. Experiments show that both the noise amplitude and spatial gradient on the measurement panel are reduced. In the presence of external disturbance, the magnetic field gradient decreased from 117.84 to 2.78 pT/m. The average sensitivity decreased from 238.19 fT/Hz1/2@1–40 Hz to 22.18 fT/Hz1/2@1–40 Hz, significantly improving the MCG signal quality.
30 December 2024 in IEEE Access
The steady-state visually evoked magnetic field (SSVEF) is a promising modality in brain-computer interference (BCI), which has the advantages of being non-invasive and non-contact. The combination of optically pumped magnetometers (OPM) and artificial intelligence technology makes SSVEF measurements more portable, accurate, and cost-effective. This paper examines the distribution of the human brain visually evoked magnetic field experimentally and then presents an SSVEF measurement system based on an OPM. A three-block temporal convolutional neural network (3B-TCN) is developed to classify brain magnetic signals. A data augmentation method based on statistical analysis of SSVEF signals is proposed, which generates 30,000 sets of data to train the 3B-TCN. The SSVEF signal classification accuracies of the 3B-TCN network are 96.61%, 92.36%, and 86.75% for 10 s, 5 s, and 2 s time length data, respectively. The impact of visually fatigued states on BCI is studied. The accuracy of controlling the character in the game is above 90% when the subjects are in a normal state, but it decreases considerably when the subjects are visually fatigued. The experimental results demonstrate the feasibility of realizing BCI using an OPM sensor and a convolutional neural network.