Zihan Sun

Zihan Sun

Auto-generated profile, based on publicly available information

Zihan Sun

College of Electronic and Information Engineering, Sichuan University, Chengdu, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2022 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
ZSZihan Sun
Zihan Sun
LYliping yan
liping yan
XZXiang Zhao
Xiang Zhao
RGRichard Xian-Ke Gao
Richard Xian-Ke Gao
An ultra-wideband frequency selective surface (FSS) absorber with high angular stability and polarization independency applied in microwave band is proposed. The absorber is composed of three identical Teflon layers and dual FSS layers with distinct patterns. The miniaturized FSSs with unique patterns demonstrate advantages of facile manipulation of the impedance and multiple resonances in an ultrawide frequency range. The use of identical dielectric substrate greatly reduces the complexity in the absorber design, compared with the conventional way that requires variable dielectric constants for a multilayer structure. Experimental results reveal that more than 90% absorption rate in the frequency range of 2.79 – 20.62 GHz for normal incidence is achieved. The absorption rate can still retain more than 80% in the range of 4.41 – 20.93 GHz for both TE and TM polarizations with the incidence of 60° .

15 December 2021
Verified
Conference Paper
Closed access
ZYZexin Yan
Zexin Yan
ZSZihan Sun
Zihan Sun
BZBoyu Zhang
Boyu Zhang
Chi MaChi Ma
Chi Ma
JLJiangtao Li
Jiangtao Li
In the power system, air arc faults are very common, in order to study the air arc characteristics, this paper mainly builds an arc generator power module and measures the output voltage waveform. And using the power module and the stepper motor based arc pulling device to build AC air arc generator, which can realize the simulation of AC air arc fault with different arc spacing for different loads under 380 V AC power supply. In order to carry out practical verification, this paper in the 40 Ω, 33 Ω, 20 Ω under the three load AC air arc fault experiments, record the arc voltage and current waveform and analysis, the AC air arc has the following characteristics: different load AC arc have obvious zero rest phenomenon; the voltage amplitude when the arc is lit is higher than it when off; the same power supply, the heavier the load, the higher the arc current. Due to the existence of arc resistance, the arc current is less than the normal operating current; the power consumed to maintain the stable burning of the arc is not large compared to the power of the circuit itself, and the series AC arc fault is easy to maintain. In this paper, it is experimentally concluded that the AC arc has the above properties to provide a basis for further research on the properties of the AC air arc.