Matheus Branco Arcadepani

Matheus Branco Arcadepani

Auto-generated profile, based on publicly available information

Matheus Branco Arcadepani

Institute of Science and Technology, So Paulo State University (UNESP), Sorocaba, Brazil

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MAMatheus B. Arcadepani
Matheus B. Arcadepani
AMAlexandre C. Moreira
Alexandre C. Moreira
Helmo Kelis Morales ParedesHelmo Kelis Morales Paredes
Helmo Kelis Morales Paredes
This letter introduces a novel approach to responsibility assignment in harmonic generation, grounded in Conservative Power Theory (CPT). The methodology is derived through an analysis of the CPT's residual current component. To demonstrate the effectiveness of the approach, a comparison is carried out with the methodologies presented in (Gianesini et al., 2023), revealing that, although the interpretations are analogous, the proposed approach stands out for its remarkable simplicity and ease of implementation, providing significant advantages in terms of practical application. In contrast to methods documented in the literature, the method proposed in this letter exclusively utilizes voltage and current measurements obtained at a single point, thus characterizing it as a non-invasive method. This characteristic eliminates the need to determine the harmonic impedances of the system or install passive or active elements.

31 December 2021 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
MAMatheus Branco Arcadepani
Matheus Branco Arcadepani
DRDiego Tardivo Rodrigues
Diego Tardivo Rodrigues
AMAlexandre Candido Moreira
Alexandre Candido Moreira
JBJakson Bonaldo
Jakson Bonaldo
HJHildo Guillardi Júnior
Hildo Guillardi Júnior
Helmo Kelis Morales ParedesHelmo Kelis Morales Paredes
Helmo Kelis Morales Paredes
Discussions on the different methods for sharing responsibilities regarding harmonic distortions in power grids have received wide attention in the area of power quality. This paper proposes a methodology based on Conservative Power Theory (CPT) for responsibility assignment due to the harmonic voltage distortions present at the point of common coupling. First, a theoretical basis for analyzing the orthogonal current decomposition of CPT under non-sinusoidal conditions is presented. Next, using the frequency domain, a methodology is introduced to separate the contributions of the harmonic voltage distortions in the CPT's orthogonal currents. To illustrate the application of the proposed methodology, it is simulated a real large-scale electrical system composed of an energy utility and three industrial plants connected to the same common coupling point. Finally, the results obtained are compared to other method showing the effectiveness of the proposed approach.

15 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
Helmo Kelis Morales ParedesHelmo Kelis Morales Paredes
Helmo Kelis Morales Paredes
MAMatheus Branco Arcadepani
Matheus Branco Arcadepani
AMAlexandre Candido Moreira
Alexandre Candido Moreira
FGFlávio Alessandro Serrão Gonçalves
Flávio Alessandro Serrão Gonçalves
Fernando MarafãoFernando Marafão
Fernando Marafão
Considering the proliferation of power electronics applications and distributed energy resources, modern power grids are facing a significant increase in harmonic currents circulation and supply voltage deterioration, occasionally associated with small frequency variations. In such a context, the understanding of power phenomena in circuits with linear and non-linear loads under non-sinusoidal voltage conditions is nontrivial and still does not allow for an easy interpretation of harmonic sources, harmonic power flow or the identification of the parameters of a proper equivalent circuit. The main challenge is to develop modern theoretical approaches for load characterization, modeling, and parameter estimation so that new techniques can be formulated to provide adequate guiding for the analysis, compensation, revenue metering, accountability and other applications of power systems. Thus, based on the Conservative Power Theory (CPT) and further decomposition of its apparent power and power factor definitions, this paper proposes a novel methodology for estimating equivalent parameters and for proposing proper equivalent circuits capable of representing/modeling the main characteristics of single-phase generic loads (black boxes) and the related power phenomena in terms of passive dipoles (linear loads) or of harmonic voltage/current sources and their intrinsic transimpedances/transadmittances (non-linear loads). Simulation and experimental results were depicted to support and validate the proposed approach, showing that it might be a powerful modeling technique to represent generic loads in a modern power grid scenario, while being used for complex applications such as reactive power compensation or accountability in circuits with nonlinear loads and distorted voltages.

15 August 2021
Verified
Conference Paper
Closed access
MRMarcus V. M. Rodrigues
Marcus V. M. Rodrigues
Helmo Kelis Morales ParedesHelmo Kelis Morales Paredes
Helmo Kelis Morales Paredes
FPFelipe L. Paes
Felipe L. Paes
MAMatheus Branco Arcadepani
Matheus Branco Arcadepani
FGFlávio Alessandro Serrão Gonçalves
Flávio Alessandro Serrão Gonçalves
Fernando MarafãoFernando Marafão
Fernando Marafão
Este trabalho apresenta a implementação de um filtro ativo de potência universal (FAPU) monofásico, que consiste da integração de um filtro ativo paralelo e um filtro ativo série, com o objetivo de realizar a compensação de distúrbios relacionados a tensão e a corrente de forma simultânea. A abordagem proposta para o FAPU permite que a corrente pela rede seja senoidal e em fase com a tensão, e as cargas sejam fornecidas com tensão eficaz constante e forma de onda senoidal. Para gerar o sinal de referência da corrente é utilizada a Teoria de Potência Conservativa além de um controlador do tipo proporcional ressonante para controlar os sinais de tensão e corrente. Resultados de simulação são apresentados mostrando a eficácia da estratégia de compensação proposta.