This paper formulates an optimization-based algorithm for the compensation of unwanted current terms by means of distributed electronic power converters, such as active power filters and grid-connected inverters. The compensation goal consists in achieving suitable load conformity factors, defined at the source side and within a feasible power region in terms of the power converter capability. Based on the measured load quantities and on a certain objective function, the algorithm tracks the expected source currents, which are thereupon used to calculate proper scaling coefficients and, therefore, the compensation current references. It improves the power quality at the point of common coupling and enables full exploitation of distributed energy resources, increasing their efficiency. The compensation is based on a decoupled current decomposition and on an optimization-based algorithm. In this paper, the strategy is applied to nonlinear and unbalanced three-phase four-wire circuit, under nonsinusoidal and asymmetrical voltage conditions. The steady-state and dynamic behaviors have been analyzed by theoretical, simulation, and experimental results. Furthermore, the proposed approach is also compared to other compensation strategies showing its effectiveness.
This paper investigates the problem of control design for dc–dc converters, where the solution is especially suitable to address variations in the input voltage, a frequent situation in photovoltaic systems, and the problem of constant power load, where a nonlinear load is connected to the output of the converter. The proposed approach models the converters in terms of Linear Parameter-Varying (LPV) models, which are used to compute gain-scheduled robust gains. The synthesis conditions provide stabilizing controllers with an attenuation level of disturbances in terms of the norm. Moreover, the design conditions can also overcome pole locations to comply with physical application restrictions when ensuring transient performance. The validation of the controllers is made via simulation of the classical converters (buck, boost and buck-boost), showing that the proposed method is a viable and generalized control solution that works for all three converters, with guarantees of closed-loop stability and good performance.
31 December 2021 in IEEE Latin America Transactions
Discussions on the different methods for sharing responsibilities regarding harmonic distortions in power grids have received wide attention in the area of power quality. This paper proposes a methodology based on Conservative Power Theory (CPT) for responsibility assignment due to the harmonic voltage distortions present at the point of common coupling. First, a theoretical basis for analyzing the orthogonal current decomposition of CPT under non-sinusoidal conditions is presented. Next, using the frequency domain, a methodology is introduced to separate the contributions of the harmonic voltage distortions in the CPT's orthogonal currents. To illustrate the application of the proposed methodology, it is simulated a real large-scale electrical system composed of an energy utility and three industrial plants connected to the same common coupling point. Finally, the results obtained are compared to other method showing the effectiveness of the proposed approach.
12 June 2025 in IEEE Open Journal of Industry Applications
The Grid-Connected Inverter is responsible for exchanging energy between the electrical grid and energy sources, such as photovoltaic and storage. The interconnection stability of these inverters may be addressed via their impedance characteristics, which comprise the control system and the ac filter. In many cases, the stability deteriorates when these devices are placed in weak grids due to the known effects of PLL and voltage feedforward. LCL-type ac filters and resonant-based controllers also pose challenges to the stability of the operation. This work proposes an approach to impedance shaping to stabilize LCL-type grid-connected inverters in nonideal grids with long feeders and disturbing loads. The method relies on regulating the voltage feedforward gain by disturbing & adapting the system based on the distortion of the output current. The technique enables the self-stabilization of the inverter even when an instability is already triggered and without the need for impedance measurements or processor-intensive algorithms. A frequency sweep verification is performed to measure the converter's impedance and validate it against the theoretical one. An hardware experiment is implemented to evaluate the stability of the converter for large grid impedance variations using the proposed impedance shaping approach.
The growing demand for high-capacity optical networks has driven the advancement of digital coherent optical communication systems, which rely on sophisticated signal processing to mitigate transmission impairments, including nonlinear fiber distortions. Traditional nonlinear compensation techniques, such as the Inverse Volterra Series Transfer Function (IVSTF) and Digital Back Propagation (DBP), are computationally expensive and require oversampling. Machine learning-based equalizers offer reduced complexity and improved adaptability. However, for dispersion-uncompensated systems with a high bandwidth-reach product, the computational complexity increases, becoming a significant concern. This work presents a multi-objective optimization approach for nonlinear equalization, balancing performance and computational cost. A sequentialized multilayer perceptron (MLP)-based nonlinear equalizer is applied to a 16-QAM digital coherent optical system over a 150 km uncompensated link at 112 Gbps. Various hyperparameter configurations, tap and neuron counts, are evaluated to identify optimal trade-offs. A Pareto front analysis quantifies the complexity-performance trade-off, providing insights into selecting an optimal equalizer configuration based on system constraints.
The water footprint is qualitative and quantitative indicator of water use, which can be defined as the total volume of water used, direct and indirect (water consumption that is measured, and that implicit in the production of goods and services). The index provides managers with a measurable indicator for decision-making in the management of water resources. The research sought to calculate the water footprint of the Barão Geraldo campus, University of Campinas (Unicamp) development a platform, fed with data on water consumption, quantity of meals, and other items, provided by the responsible sector in Unicamp. From the access to the water footprint indices and estimates, technological actions and aimed at sustainability actions can be implemented, incorporating the pillars environmental, social and governance factors into water management.