Masoud Farzaneh

Masoud Farzaneh

Auto-generated profile, based on publicly available information

Masoud Farzaneh

Department of Applied Sciences (DSA), University of Quebec at Chicoutimi, Chicoutimi, QC, Canada

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2008
Verified
Book Chapter
Closed access
PDF file
MFMasoud Farzaneh
Masoud Farzaneh
CVChristophe Volat
Christophe Volat
ALAndré Leblond
André Leblond

22 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Hongwei MeiHongwei Mei
Hongwei Mei
HJHuaiyuan Jiang
Huaiyuan Jiang
FYFanghui Yin
Fanghui Yin
LWLiming Wang
Liming Wang
MFMasoud Farzaneh
Masoud Farzaneh
Composite insulator is prone to internal defects such as air gaps which seriously endanger the safety of power systems. To detect the internal defects in composite insulators, a terahertz (THz) imaging method based on edge detection algorithm was proposed in this article. First, air gap defect sample consisting of planar multilayers was imaged based on the envelope area of the THz reflection waveform. Then, Canny operator was applied to extract the edges of the defects. After that, the time interval of defect characteristic pulses was used to calculate the defect depth and then 3-D imaging of defects was, therefore, obtained. The experimental results showed that the imaging method based on envelope area was very effective in determining the edges of air gap defect and it had better performance compared with those using pulse amplitude or time interval as parameter for defect imaging. According to the results, the accuracy was quite satisfactory when the defect depth was above 0.339 mm. To verify the effectiveness of the proposed method, the developed THz imaging system was also applied to the rod of composite insulator. It was found that the relative error was smaller along the axial direction of the rod than the lateral direction.

21 January 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SHSeyedkazem Hosseini
Seyedkazem Hosseini
Shamsodin TaheriShamsodin Taheri
Shamsodin Taheri
MFMasoud Farzaneh
Masoud Farzaneh
HTHamed Taheri
Hamed Taheri
This paper proposes a high performance shadetolerant maximum power point tracking (STMPPT) technique for DC-DC converter stage of photovoltaic (PV) applications. The average current-mode control (ACMC) is utilized to regulate the PV array current using two feedback control loops. The currentmode control is a superior scheme in control of DC-DC power electronic converters. The proposed STMPPT technique operates in two modes. The ACMC with the perturb and observe (P&O) MPPT algorithm functions in a local MPPT (LMPPT) mode under normal irradiance condition. When the PV array is likely to be partially shaded, a global MPPT (GMPPT) subroutine effectively scans the PV profile to optimize the PV system operation. This is achieved by implementing simple innovations to the ACMC-based P&O algorithm. The innovations benefit from useful observations of I-V characteristics. The idea behind using the I-V characteristics is to significantly reduce the search space, make the algorithm independent of shading conditions and PV array configuration, and inherently recognize the occurrence of partial shading conditions (PSCs). The proposed STMPPT technique enables very fast and reliable tracking of global maximum power point (GMPP). In addition, it can stably work under dynamic environmental change without losing correct sense of tracking direction. Its simplicity and independency would offer a viable solution for PV converter products. Simulation and experimental performance assessments are presented under different operating conditions that could happen in outdoor PV installations.

27 February 2006 in Hydrological Processes
Verified
Journal Article
Closed access
PDF file
MJM. Javan‐Mashmool
M. Javan‐Mashmool
CVC. Volat
C. Volat
MFM. Farzaneh
M. Farzaneh

8 February 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SHSeyedkazem Hosseini
Seyedkazem Hosseini
Shamsodin TaheriShamsodin Taheri
Shamsodin Taheri
MFMasoud Farzaneh
Masoud Farzaneh
HTHamed Taheri
Hamed Taheri
Accurate modeling of photovoltaic (PV) modules is required to predict performance of PV systems in various climatic conditions, often far different than manufacturer specifications. Snowfall during cold months reduces output of PV modules. As the application of PV systems is increasing in cold areas, it is vitally important to address this issue through an appropriate method capable of estimating PV performance due to snow effect. This paper proposes a novel PV modeling approach that can represent instantaneous electrical characteristics of PV modules in the presence of uniform snow coverage. The proposed model utilizes the Bouguer-Lambert Law to estimate the level of insolation reaching surface of snow-covered PV cells. This is achieved by introducing an extinction coefficient which depends on the snow properties. To study the efficiency of PV cells at low insolation levels, a two-diode equivalent circuit model is employed. The simulation results of the proposed model are validated with experimental measurements from field tests for different commercial PV modules as well as real data collected by the SCADA system of a 12-MW grid-connected PV farm. Good agreement was observed between power generation results estimated from the proposed model and those obtained experimentally on snow-covered PV systems. This model would be helpful for researchers and PV systems developers in cold regions.

26 August 2016 in Energies
Verified
Journal Article
Open access
PDF file
Arshad ArshadArshad Arshad
Arshad Arshad
ANAzam Nekahi
Azam Nekahi
SMScott McMeekin
Scott McMeekin
MFMasoud Farzaneh
Masoud Farzaneh
Silicone rubber insulators are replacing the conventional ceramic and porcelain insulators rapidly in power transmission and distribution industry. Very limited field knowledge is available about the performance of silicone rubber insulators in polluted and contaminated environments and therefore need further investigation. A comprehensive analysis of silicone rubber sheets (intended for coating outdoor insulators) was carried out in this paper based on experimental results. The main performance parameters analyzed were arc inception voltage and flashover voltage. Dependence of these parameters on equivalent salt deposit density (ESDD), non-soluble salt deposit density (NSDD), relative humidity, ambient temperature, fog rate, dry band formation, dry band location and number of dry bands were investigated extensively. Insulator orientation and its effect on performance were also studied. The authors believe that this paper will provide a comprehensive knowledge about the flashover characteristics of silicone rubber insulators under humid, contaminated and dry band conditions. These results could be used in the selection and design of silicone rubber insulators for polluted environments.