Katharine Virginia Greco

Katharine Virginia Greco

Auto-generated profile, based on publicly available information

Katharine Virginia Greco

Massachusetts Institute of Technology

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2018 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
KGKatharine V. Greco
Katharine V. Greco
AFAntoni Forner-Cuenca
Antoni Forner-Cuenca
AMAdrian Mularczyk
Adrian Mularczyk
JEJens Eller
Jens Eller
FBFikile Brushett
Fikile Brushett

24 May 2021 in ACS Applied Energy Materials
Verified
Journal Article
Closed access
Zhiming LiangZhiming Liang
Zhiming Liang
NAN. Harsha Attanayake
N. Harsha Attanayake
KGKatharine V. Greco
Katharine V. Greco
BNBertrand J. Neyhouse
Bertrand J. Neyhouse
JBJohn Barton
John Barton
SOSusan A. Odom
Susan A. Odom

17 November 2021 in ACS Applied Energy Materials
Verified
Journal Article
Closed access
KGKatharine V. Greco
Katharine V. Greco
JBJude K. Bonesteel
Jude K. Bonesteel
NCNicolas Chanut
Nicolas Chanut
CWCharles Tai-Chieh Wan
Charles Tai-Chieh Wan
YCYet-Ming Chiang
Yet-Ming Chiang
FBFikile Brushett
Fikile Brushett

5 September 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
RJRémy Richard Jacquemond
Rémy Richard Jacquemond
MHMaxime van der Heijden
Maxime van der Heijden
EBEmre Burak Boz
Emre Burak Boz
EREric Ricardo Carreón Ruiz
Eric Ricardo Carreón Ruiz
KGKatharine Virginia Greco
Katharine Virginia Greco
AFAntoni Forner-Cuenca
Antoni Forner-Cuenca
The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.

14 June 2022 in Energy Technology
Verified
Journal Article
Open access
KTKevin M. Tenny
Kevin M. Tenny
KGKatharine V. Greco
Katharine V. Greco
MHMaxime van der Heijden
Maxime van der Heijden
Tommaso PiniTommaso Pini
Tommaso Pini
AMAdrian Mularczyk
Adrian Mularczyk
FBFikile Brushett
Fikile Brushett
Compressing porous carbon electrodes is a common approach to improve flow battery performance, but the resulting impact on electrode structure, fluid dynamics, and cell performance is not well understood. Herein, microtomographic imaging, load cell testing, and flow cell diagnostics are employed to characterize how compression‐induced changes impact pressure drop, polarization, and mass‐transfer scaling. Five different compressions are tested, spanning ranges typically used in literature, for AvCarb 1071 cloth (0%, 9%, 20%, 25%, 32%) and Freudenberg H23 paper (0%, 8%, 12%, 17%, 22%). It is found that the two electrode structures have distinct responses to compression, resulting in differing optimal conditions identified for each material; specifically, the Freudenberg H23 exhibits lower combined ohmic, charge‐transfer, and mass‐transport values at 8% compression, resulting in improved electrochemical performance across all compressive values, as compared to the optimal AvCarb 1071 compression (20%). Overall, Freudenberg H23 exhibits a greater sensitivity to compression with peak electrochemical activity correlating with increased permeability, whereas AvCarb 1071 is insensitive to compressive loads but produces lower electrochemical performance. Herein, the trade‐offs of mechanical robustness on fluid‐dynamic and electrochemical performance between the two electrodes are demonstrated by the aforementioned findings, suggesting each could be used for specific operating environments.

1 December 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
CWCharles Tai-Chieh Wan
Charles Tai-Chieh Wan
KGKatharine V. Greco
Katharine V. Greco
AAAmira Alazmi
Amira Alazmi
RDRobert M. Darling
Robert M. Darling
YCYet-Ming Chiang
Yet-Ming Chiang
FBFikile Brushett
Fikile Brushett
Electrochemical reactors often employ high surface area electrocatalysts to accelerate volumetric reaction rates and increase productivity. While electrocatalysts can alleviate kinetic overpotentials, diffusional resistances at the pore-scale often prevent full catalyst utilization. The effect of intraparticle diffusion on the overall reaction rate can be quantified through an effectiveness factor expression governed by the Thiele modulus parameter. This analytical approach is integral to the development of catalytic structures for thermochemical processes and has previously been extended to electrochemical processes by accounting for the relationship between reaction kinetics and electrode overpotential. In this paper, we illustrate the method by deriving the expression for the potential-dependent Thiele modulus and using it to quantify the effectiveness factor for porous electrocatalytic structures. Specifically, we demonstrate the application of this mathematical framework to spherical microparticles as a function of applied overpotential across catalyst properties and reactant characteristics. The relative effects of kinetics and mass transport are related to overall reaction rates, revealing markedly lower catalyst utilization at increasing overpotential. Subsequently, we generalize the analysis to different catalyst shapes and provide guidance on the design of porous catalytic materials for use in electrochemical reactors.