Brno University of Technology, Faculty of Mechanical Engineering, V. Kaplan Department of Fluid Engineering, Technická 2896/2, Brno 61669, Czech Republic
Auto-generated profile, based on publicly available information
František Pochylý
Brno University of Technology, Faculty of Mechanical Engineering, V. Kaplan Department of Fluid Engineering, Technická 2896/2, Brno 61669, Czech Republic
Cyanobacterial water blooms represent toxicological, ecological and technological problems around the globe. When present in raw water used for drinking water production, one of the best strategies is to remove the cyanobacterial biomass gently before treatment, avoiding cell destruction and cyanotoxins release. This paper presents a new method for the removal of cyanobacterial biomass during drinking water pre-treatment that combines hydrodynamic cavitation with cold plasma discharge. Cavitation produces press stress that causes Microcystis gas vesicles to collapse. The cyanobacteria then sink, allowing for removal by sedimentation. The cyanobacteria showed no signs of revitalisation, even after seven days under optimal conditions with nutrient enrichment, as photosynthetic activity is negatively affected by hydrogen peroxide produced by plasma burnt in the cavitation cloud. Using this method, cyanobacteria can be removed in a single treatment, with no increase in microcystin concentration. This novel technology appears to be highly promising for continual treatment of raw water inflow in drinking water treatment plants and will also be of interest to those wishing to treat surface waters without the use of algaecides.
This work is focused on reduction of swirling in cases from hydraulic machinery and, thus, mitigation of instabilities associated with swirling flow. We study this problem analytically using the torque integral equation, numerically using computational fluid dynamics (CFD) simulations, and experimentally using a swirl generator that generates swirling flow approximating that in a draft tube of a hydro turbine operating at a part load, featuring an unsteady spiral vortex—the vortex rope. The analytical description elucidates the effect of different installations on the circumferential velocity. Unconventional conical perforated installations targeting at increasing the dissipation were proposed and tested. The rather unsatisfactory results led to proposing fins placed unconventionally away from the wall, closer to the diffuser axis, which were subsequently shown to be able to reliably suppress the unsteady vortex rope. Their effect is documented by an analysis of CFD results including the proper orthogonal decomposition as well as experimental observations and measurements.