Juozas Kulys

Juozas Kulys

Auto-generated profile, based on publicly available information

Juozas Kulys

Institute of Biochemistry, Vilnius University, Mokslininkų 12, LT-08662 Vilnius, Lithuania

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2014 in Sensors
Verified
Journal Article
Open access
PDF file
Romas BaronasRomas Baronas
Romas Baronas
JKJuozas Kulys
Juozas Kulys
ALAlgirdas Lančinskas
Algirdas Lančinskas
AZAntanas Zilinskas
Antanas Zilinskas
The optimization-based quantitative determination of multianalyte concentrations from biased biosensor responses is investigated under internal and external diffusion-limited conditions. A computational model of a biocatalytic amperometric biosensor utilizing a mono-enzyme-catalyzed (nonspecific) competitive conversion of two substrates was used to generate pseudo-experimental responses to mixtures of compounds. The influence of possible perturbations of the biosensor signal, due to a white noise- and temperature-induced trend, on the precision of the concentration determination has been investigated for different configurations of the biosensor operation. The optimization method was found to be suitable and accurate enough for the quantitative determination of the concentrations of the compounds from a given biosensor transient response. The computational experiments showed a complex dependence of the precision of the concentration estimation on the relative thickness of the outer diffusion layer, as well as on whether the biosensor operates under diffusion- or kinetics-limited conditions. When the biosensor response is affected by the induced exponential trend, the duration of the biosensor action can be optimized for increasing the accuracy of the quantitative analysis.


1 October 2012 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
VAVytautas Ašeris
Vytautas Ašeris
Romas BaronasRomas Baronas
Romas Baronas
JKJuozas Kulys
Juozas Kulys

3 July 2012 in Sensors
Verified
Journal Article
Open access
PDF file
Romas BaronasRomas Baronas
Romas Baronas
JKJuozas Kulys
Juozas Kulys
KPKarolis Petrauskas
Karolis Petrauskas
JRJulija Razumiene
Julija Razumiene
This paper presents a mathematical model of carbon nanotubes-based mediatorless biosensor. The developed model is based on nonlinear non-stationary reaction-diffusion equations. The model involves four layers (compartments): a layer of enzyme solution entrapped on a terylene membrane, a layer of the single walled carbon nanotubes deposited on a perforated membrane, and an outer diffusion layer. The biosensor response and sensitivity are investigated by changing the model parameters with a special emphasis on the mediatorless transfer of the electrons in the layer of the enzyme-loaded carbon nanotubes. The numerical simulation at transient and steady state conditions was carried out using the finite difference technique. The mathematical model and the numerical solution were validated by experimental data. The obtained agreement between the simulation results and the experimental data was admissible at different concentrations of the substrate.

16 April 2012 in Sensors
Verified
Journal Article
Open access
PDF file
DSDainius Simelevicius
Dainius Simelevicius
Romas BaronasRomas Baronas
Romas Baronas
JKJuozas Kulys
Juozas Kulys
In this paper the operation of an amperometric biosensor producing a chemically amplified signal is modelled numerically. The chemical amplification is achieved by using synergistic substrates. The model is based on non-stationary reaction-diffusion equations. The model involves three layers (compartments): a layer of enzyme solution entrapped on the electrode surface, a dialysis membrane covering the enzyme layer and an outer diffusion layer which is modelled by the Nernst approach. The equation system is solved numerically by using the finite difference technique. The biosensor response and sensitivity are investigated by altering the model parameters influencing the enzyme kinetics as well as the mass transport by diffusion. The biosensor action was analyzed with a special emphasis to the effect of the chemical amplification. The simulation results qualitatively explain and confirm the experimentally observed effect of the synergistic substrates conversion on the biosensor response.

12 January 2012 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
JKJuozas Kulys
Juozas Kulys
IBIrina Bratkovskaja
Irina Bratkovskaja