Jose Manuel Perez

Jose Manuel Perez

Auto-generated profile, based on publicly available information

Jose Manuel Perez

CIEMAT, Madrid, Spain

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 1991 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
POP. Olmos
P. Olmos
JDJ.C. Diaz
J.C. Diaz
JPJ.M. Perez
J.M. Perez
PGPedro Gómez-Vilda
Pedro Gómez-Vilda
VRV. Rodellar
V. Rodellar
JPJ.L. de Pablos
J.L. de Pablos

1 February 1992 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
POP. Olmos
P. Olmos
JDJ.C. Diaz
J.C. Diaz
JPJ.M. Perez
J.M. Perez
GGG. Garcia-Belmonte
G. Garcia-Belmonte
PGPedro Gómez-Vilda
Pedro Gómez-Vilda
VRV. Rodellar
V. Rodellar

9 November 2010 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MCMario Canadas
Mario Canadas
MEMiguel Embid
Miguel Embid
ENEduardo Lage Negro
Eduardo Lage Negro
DMDesco Menéndez Manuel
Desco Menéndez Manuel
JVJuan Jose Vaquero
Juan Jose Vaquero
JPJose Manuel Perez
Jose Manuel Perez
In this work, we compare two commercial positron emission tomography (PET) scanners installed at CIEMAT (Madrid, Spain): the ClearPET and the rPET-1. These systems have significant geometrical differences, such as the axial field of view (110 mm on ClearPET versus 45.6 mm on rPET-1), the configuration of the detectors (whole ring on ClearPET versus one pair of planar blocks on rPET-1) and the use of an axial shift between ClearPET detector modules. We used an assessment procedure that fulfilled the recommendations of the National Electrical Manufacturers Association (NEMA) NU 4-2008 standard. The methodology includes studies of spatial resolution, sensitivity, scatter fraction, count losses and image quality. Our experiments showed a central spatial resolution of 1.5 mm (transaxial), 3.2 mm (axial) for the ClearPET and 1.5 mm (transaxial), 1.6 mm (axial) for the rPET-1, with a small variation across the transverse axis on both scanners (~1 mm). The absolute sensitivity at the centre of the field of view was 4.7% for the ClearPET and 1.0% for the rPET-1. The peak noise equivalent counting rate for the mouse-sized phantom was 73.4 kcps reached at 0.51 MBq/mL on the ClearPET and 29.2 kcps at 1.35 MBq/mL on the rPET-1. The recovery coefficients measured using the image quality phantom ranged from 0.11 to 0.89 on the ClearPET and from 0.14 to 0.81 on the rPET-1. The overall performance shows that both the ClearPET and the rPET-1 systems are very suitable for preclinical research and imaging of small animals.

1 January 2005 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
AMA. Muñoz
A. Muñoz
JPJ.M. Pérez
J.M. Pérez
GGG. García
G. García
FBF. Blanco
F. Blanco

15 May 2004 in Journal of Applied Physics
Verified
Journal Article
Closed access
ARA. Roldán
A. Roldán
JPJ. M. Pérez
J. M. Pérez
AWA. Williart
A. Williart
FBF. Blanco
F. Blanco
GGG. Garcı́a
G. Garcı́a
An energy deposition model for electrons in air that can be useful in microdosimetric applications is presented in this study. The model is based on a Monte Carlo simulation of the single electron scattering processes that can take place with the molecular constituents of the air in the energy range 10–10 000 eV. The input parameters for this procedure have been the electron scattering cross sections, both differential and integral. These parameters were calculated using a model potential method which describes the electron scattering with the molecular constituent of air. The reliability of the calculated integral cross section values has been evaluated by comparison with direct total electron scattering cross-section measurements performed by us in a transmission beam experiment. Experimental energy loss spectra for electrons in air have been used as probability distribution functions to define the electron energy loss in single collision events. The resulting model has been applied to simulate the electron transport through a gas cell containing air at different pressures and the results have been compared with those observed in the experiments. Finally, as an example of its applicability to dosimetric issues, the energy deposition of 10 000 eV by means of successive collisions in a free air chamber has been simulated.

28 March 2005 in Physical Review A
Verified
Journal Article
Open access
PDF file
PLPaulo LIMÃO-VIEIRA
Paulo LIMÃO-VIEIRA
FBF. Blanco
F. Blanco
JOJuan Carlos Oller
Juan Carlos Oller
AMA. Muñoz
A. Muñoz
JPJ. M. Pérez
J. M. Pérez
Nigel MasonNigel Mason
Nigel Mason
A modified experimental apparatus with improved angular resolution and stability has been used to measure the total electron scattering cross sections for SF6 and SF5CF3 in the energy range of 100–5000eV. A detailed analysis of the experimental error sources is provided. The experimental results are compared with integral elastic and inelastic cross sections calculated using the independent atom model approximation and a modified single-center additivity rule for electron energies ranging from 1to10,000eV. The accuracy of these approximations method is discussed through a comparison with the experimental results. Previous cross-sectional data for SF6 are compared with the present theoretical and experimental results. For SF5CF3, we present the first electron scattering cross-sectional data for the 100–10,000eV energy range, as well as the first empirical determination of the molecular polarizability.