1 November 2006 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
A new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon microstrip detectors, is shown to perform well even with “slow” signals from a MWPC, keeping a signal-to-noise ratio of 9. For every trigger the system reads three consecutive in-time samples, thus allowing to extract information on the signal shape and its timing. The effective time window is reduced from ∼3 μs for the Gassiplex to below 400 ns for the APV25-S1 chip, reducing pile-up events at high particle rate. A significant improvement of the signal-to-background ratio by a factor 5–6 with respect to the original readout has been measured in the central region of the RICH detector. Due to its pipelined architecture, the new readout system also considerably reduces the dead time per event, allowing efficient data taking at higher trigger rate
20 January 2022 in IEEE Transactions on Nuclear Science
We present the IDeF-X HDBD integrated circuit, our latest 32-channel Application Specific Integrated Circuit devoted to semiconductor photon counting X-ray detectors, designed to read charges ranging from -40 to 40 fC. The chip reaches an Equivalent Noise Charge floor (ENC) of 17 el. rms and is optimized for low input capacitance (<10 pF). Each channel is based on an optimized charge sensitive amplifier followed by a CR-RC2 filter and a peak detector with a power consumption of 850 μW/channel. Gain and shaping times are tunable. This circuit has been designed with radiation mitigation techniques to meet space application requirements. This ASIC can read either Cadmium Telluride or Silicon detectors for imaging-spectroscopy applications. An energy resolution of 230 eV FHWM at 6 keV, and a low-level threshold of 1.2 keV were demonstrated with a single pixel silicon drift detector connected to one channel.
1 March 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 August 1999 in IEEE Transactions on Nuclear Science
28 November 2023 in IEEE Transactions on Nuclear Science
This paper proposes and evaluates an architecture for a low-power Time-to-Digital Converter (TDC) with high resolution, optimized for high-rate operation (40MSa/channel), and integration with analog front-end in multichannel readout chips in 130 nm CMOS technology. The converter is based on a three-step architecture. The first step uses a counter and the following ones are based on two types of Delay-Line (DL) structures. A programmable Time Amplifier (TA) is used between the second and third steps to reach a final resolution of 24.4 ps in the standard mode of operation. In addition, this architecture uses common continuously stabilized master blocks that control the channels against the effects of global Process, Voltage, and Temperature (PVT) variations. We also propose a per-channel DL gain correction based on a trimmable block to correct mismatch effect. The area of the TDC channel is only 0.051 mm 2 . For a 40MSa/channel rate, the TDC average power consumption measured per channel is 2.2 mW for a 100% hit occupancy and decreases to 311 μW for the 10% occupancy specified for our main application. The demonstrated compactness and low power consumption fully match our requirements for integration into multichannel front-end chips. The experimental results demonstrate good timing performance over a broad range of operating temperatures (-35°C and 65°C), which conforms to our expectations. For example, the measured timing integral nonlinearity is better than ±1 LSB (±25 ps), and the overall timing precision is better than 21 ps RMS.
30 September 2024 in IEEE Transactions on Nuclear Science
WEST, the Tungsten Environment Steady state Tokamak at IRFM (France), is currently being equipped with two new plasma-monitoring systems based on Thomson Scattering. Nearly fifty optical viewing lines will be installed to collect scattered light near the core plasma region and in the plasma pedestal. The collected light pulses are forwarded along optical fiber bundles to polychromators where they are optically filtered into five channels and converted to swift electrical pulses. A custom fast digitizer board adapted to the polychromators was designed to capture these signals. This Nectarine board provides six triggered fast channels to catch the scattered pulse shape at 1 to 3.2 GS/s thanks to three Nectar chips. Six additional ADC channels provide a slower sampling rate for background monitoring. This contribution describes and discusses the performances of the real-time data acquisition and processing system, especially the Nectarine board, designed specifically for WEST’s new Thomson Scattering diagnostics.