Panagiotis Mililis

Panagiotis Mililis

Auto-generated profile, based on publicly available information

Panagiotis Mililis

Arrhythmia Unit Onassis Cardiac Surgery Center Athens Greece

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2023 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PMPanagiotis Mililis
Panagiotis Mililis
OKOurania Kariki
Ourania Kariki
ASAthanasios Saplaouras
Athanasios Saplaouras
George BazoukisGeorge Bazoukis
George Bazoukis
SDStylianos Dragasis
Stylianos Dragasis
MEMichael Efremidis
Michael Efremidis

3 June 2025 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
OKOurania Kariki
Ourania Kariki
ASAthanasios Saplaouras
Athanasios Saplaouras
PMPanagiotis Mililis
Panagiotis Mililis
KPKonstantinos Pamporis
Konstantinos Pamporis
TETheodoros Efremidis
Theodoros Efremidis
MEMichael Efremidis
Michael Efremidis

27 October 2026 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
ASAthanasios Saplaouras
Athanasios Saplaouras
PMPanagiotis Mililis
Panagiotis Mililis
SKStavroula Koskina
Stavroula Koskina
OKOurania Kariki
Ourania Kariki
George BazoukisGeorge Bazoukis
George Bazoukis
KLKonstantinos Letsas
Konstantinos Letsas

23 October 2023 in Clinical Case Reports
Verified
Journal Article
Open access
ASAthanasios Saplaouras
Athanasios Saplaouras
PMPanagiotis Mililis
Panagiotis Mililis
OKOurania Kariki
Ourania Kariki
George BazoukisGeorge Bazoukis
George Bazoukis
ABAthena Batsouli
Athena Batsouli
MEMichael Efremidis
Michael Efremidis
Key Clinical Message: R‐wave double counting is a rare cause of ventricular oversensing that can lead to inappropriate shocks. Optimizing device programming is essential for the avoidance of subsequent inappropriate therapies. R‐wave double counting is a rare cause of ventricular oversensing that can lead to inappropriate shocks. We present the case of a female patient, 52‐years‐old with a history of end‐stage hypertrophic cardiomyopathy. The patient suffered an implantable cardioverter‐defibrillator (ICD) shock. Cardiac device interrogation revealed ventricular tachycardia (VT) with a cycle length of 420 ms that was misclassified in the ventricular fibrillation (VF) zone owing to R‐wave double counting. Optimizing device programming is essential for the avoidance of subsequent inappropriate therapies. Possible therapeutic options are briefly presented in the case.

26 August 2026 in Hellenic Journal of Cardiology
Verified
Journal Article
Open access
PMPanagiotis Mililis
Panagiotis Mililis
DPDimitra Paraskevopoulou
Dimitra Paraskevopoulou
ASAthanasios Saplaouras
Athanasios Saplaouras
OKOurania Kariki
Ourania Kariki
SKStavroula Koskina
Stavroula Koskina
Maria GazouliMaria Gazouli
Maria Gazouli

20 May 2024 in Hellenic Journal of Cardiology
Verified
Journal Article
Open access
ASAntigoni Sakellaropoulou
Antigoni Sakellaropoulou
GGGeorgios Giannopoulos
Georgios Giannopoulos
DTDimitrios Tachmatzidis
Dimitrios Tachmatzidis
KLKonstantinos P. Letsas
Konstantinos P. Letsas
AAAntonios Antoniadis
Antonios Antoniadis
VVVasileios P. Vassilikos
Vasileios P. Vassilikos
Left atrial (LA) fibrosis has been shown to be associated with atrial fibrillation (AF) recurrence. Beat-to-beat (B2B) index is a non-invasive classifier, based on B2B P-wave morphological and wavelet analysis, shown to be associated with AF incidence and recurrence. In this study, we tested the hypothesis that the B2B index is associated with the extent of LA low-voltage areas (LVAs) on electroanatomical mapping. Patients with paroxysmal AF scheduled for pulmonary vein isolation, without evident structural remodeling, were included. Pre-ablation electroanatomical voltage maps were used to calculate the surface of LVAs (<0.5 mV). B2B index was compared between patients with small versus large LVAs. 35 patients were included (87% male, median age 62). The median surface area of LVAs was 7.7 (4.4-15.8) cm2 corresponding to 5.6 (3.3-12.1) % of LA endocardial surface. B2B index was 0.57 (0.52-0.59) in patients with small LVAs (below the median) compared to 0.65 (0.56-0.77) in those with large LVAs (above the median) (p=0.009). In the receiver operator characteristic curve analysis for predicting large LVAs, the c-statistic was 0.75 (p=0.006) for B2B index and 0.81 for the multivariable model including B2B index (multivariable p=0.04) and P-wave duration. In patients with paroxysmal AF without overt atrial myopathy, B2B P-wave analysis appears to be a useful non-invasive correlate of low-voltage areas-and thus fibrosis-in the LA. This finding establishes a pathophysiological basis for B2B index and its potential usefulness in the selection process of patients who are likely to benefit most from further invasive treatment.