Gyeong-Min Kim

Gyeong-Min Kim

Auto-generated profile, based on publicly available information

Gyeong-Min Kim

Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2026 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
GKGyeong-Min Kim
Gyeong-Min Kim
KeunBaDa SonKeunBaDa Son
KeunBaDa Son
YSYoon-Jeong Shin
Yoon-Jeong Shin
So-Yeun KimSo-Yeun Kim
So-Yeun Kim
Gyu-ri KimGyu-ri Kim
Gyu-ri Kim
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee
This clinical study evaluated the effect of build angle (0°, 45°, and 90°) in digital light processing (DLP) printing on the trueness and chairside adjustment of zirconia crowns and compared these outcomes with conventionally milled crowns. Ten patients each received one milled zirconia crown and three DLP-printed zirconia crowns fabricated at 0°, 45°, and 90° build angles (40 crowns total; four crowns per patient). Trueness was calculated as the root mean square (RMS) surface deviation between intraoral scans of the crowns and the CAD design. Occlusal and intaglio adjustments were quantified as the RMS deviation between pre- and post-adjustment scans. Data were analyzed using linear mixed-effects models with manufacturing method as a fixed effect and patient as a random intercept to account for within-patient clustering. Post hoc comparisons were performed using Tukey-adjusted pairwise contrasts of estimated marginal means (α = .05). Manufacturing method significantly influenced trueness in the primary linear mixed-effects model (χ2 = 20.689, P = .001). Tukey-adjusted contrasts showed lower RMS for the 0° group (49.0 µm) than for the 45° group (63.3 µm; P = .033), 90° group (70.5 µm; P = .003), and milled group (66.2 µm; P = .012). Manufacturing method also affected occlusal adjustment (χ2 = 13.904, P = .003) and intaglio adjustment (χ2 = 28.624, P < .001). The milled group required more occlusal adjustment than the 0° group (P = .011), and greater intaglio adjustment than all DLP-printed groups (all P ≤ .004). Compared with milling, DLP-printed zirconia crowns demonstrated greater trueness (lower RMS) and required less chairside adjustment. Under the tested conditions, a 0° build angle was associated with the lowest trueness RMS and the least adjustment requirements.