20 February 2021 in IEEE Transactions on Instrumentation and Measurement
A new instrument is required to accommodate the need for increased portability and accuracy in laser power measurement above 100 W. Reflection and absorption of laser light provide a measurable force from photon momentum exchange that is directly proportional to laser power, which can be measured with an electrostatic balance traceable to the SI. We aim for a relative uncertainty of $10^{-3}$ with coverage factor $k=2$ . For this purpose, we have designed a monolithic parallelogram 4-bar linkage incorporating elastic circular notch flexure hinges. The design is optimized to address the main factors driving force measurement uncertainty from the balance mechanism: corner loading errors, balance stiffness, the stress in the flexure hinges, sensitivity to vibration, and sensitivity to thermal gradients. Parasitic rotations in the free end of the 4-bar linkage during arcuate motion are constrained by machining tolerances. An analytical model shows this affects the force measurement less than 0.01%. Incorporating an inverted pendulum reduces the stiffness of the system without unduly increasing tilt sensitivity. Finite element modeling of the flexures is used to determine the hinge orientation that minimizes stress, which is therefore expected to minimize hysteresis. Thermal effects are mitigated using an external enclosure to minimize temperature gradients although a quantitative analysis of this effect is not carried out. These analyses show that the optimized mechanism is expected to contribute less than $1\times 10^{-3}$ relative uncertainty in the final laser power measurement.
11 July 2022 in EPJ Techniques and Instrumentation
The “Quantum Electro-Mechanical Metrology Suite” (QEMMS) is being designed and built at the National Institute of Standards and Technology. It includes a Kibble balance, a graphene quantum Hall resistance array and a Josephson voltage system, so that it is a new primary standard for the unit of mass, the kilogram, directly traceable to the International System of Units (SI) based on quantum constants. We are targeting a measurement range of 10 g to 200 g and optimize the design for a relative combined uncertainty of $2\times 10^{-8}$ for masses of 100 g. QEMMS will be developed as an open hardware and software design. In this article, we focus on the design of an enhanced moving and weighing mechanism for the QEMMS based on flexure pivots.
10 December 2022 in Communications Physics
The revision of the International System of Units (SI) on May 20th, 2019, has enabled new improved experiments to consolidate and simplify mechanical and quantum electrical metrology. Here, we present the direct measurement between a macroscopic mass and two quantum standards in a single experiment, in which the current used to levitate a mass passes through a graphene quantum Hall standard. The Josephson effect voltage is compared directly to the resulting quantum Hall effect voltage. We demonstrate this measurement with the use of graphene quantum Hall arrays for scaling in resistance with improved uncertainty and higher current level.
1 July 2024 in Metrologia
We studied the anelastic aftereffect of a flexure being used in a Kibble balance, where the flexure is subjected to a large excursion in velocity mode after which a high-precision force comparison is performed. We investigated the effect of a constant and a sinusoidal excursion on the force comparison. We explored theoretically and experimentally a simple erasing procedure, i.e. bending the flexure in the opposite direction for a given amplitude and time. We found that the erasing procedure reduced the time-dependent force by about 30%. The investigation was performed with an analytical model and verified experimentally with our new Kibble balance at the National Institute of Standards and Technology employing flexures made from precipitation-hardened Copper Beryllium alloy C17200. Our experimental determination of the modulus defect of the flexure yields . This result is about a factor of two higher than previously reported from experiments. We additionally found a static shift of the flexure’s internal equilibrium after a change in the stress and strain state. These static shifts, although measurable, are small and deemed uncritical for our Kibble balance application at present. During this investigation, we discovered magic flexures that promise to have very little anelastic relaxation. In these magic flexures, the mechanism causing anelastic relaxation is compensated for by properly shaping and loading a flexure with a non-constant cross-section in the region of bending.
14 September 2022 in Metrologia
Analytically the force acting on a current-carrying coil in a magnetic field can be calculated in two ways. First, a line integral can be conducted along the coil’s wire, summing up the differential force contributions. Each contribution results from a cross-product of the corresponding differential line segment with the magnetic flux density at that location. Alternatively, the coil’s energy in the field is given as a product of three factors, the number of turns, the current, and the flux threading the coil. The energy can then be obtained by executing a surface integral over the coil’s open surface using the scalar product of the differential surface element with the magnetic flux density as its integrand. The force on the coil is the negative derivative of the energy with respect to the appropriate coordinate. For yoke-based Kibble balances, the latter method is much simpler since most of the flux is contained in the inner yoke of the magnet and can be written as a simple equation. Here, we use this method to provide simple equations and their results for finding the torques and forces that act on a coil in a yoke-based magnet system. We further introduce a straightforward method that allows the calculation of the position and orientation difference between the coil and the magnet from three measurements.
31 March 2025 in Metrologia
We revisit the Kibble–Robinson theory, first proposed in 2014 by Kibble and Robinson. This theory significantly simplifies the construction and operation of Kibble balances. We conducted a theoretical investigation of the theory’s assumptions, using a corner cube as the optical target in the interferometer for velocity measurement. We find that it is advantageous to build a mechanism whose output has minimal rotation and horizontal motion. For balances with relative uncertainty targets below , the mass pan and the optical target should be suspended from a common gimbal so they have the same vertical velocity and no rotation. In this case, the measurement bias due to Abbe offset is minimized, and the bias due to corner loading is repeatable.