Frank Seifert

Frank Seifert

Auto-generated profile, based on publicly available information

Frank Seifert

National Institute of Standards and Technology, Gaithersburg, MD, United States of America

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2017 in Metrologia
Verified
Journal Article
Open access
PDF file
DHDarine Haddad
Darine Haddad
FSFrank Seifert
Frank Seifert
LCLeon Chao
Leon Chao
APAntonio Possolo
Antonio Possolo
DNDavid B Newell
David B Newell
SSStephan Schlamminger
Stephan Schlamminger

14 May 2020 in Metrologia
Verified
Journal Article
Open access
PDF file
LCLeon Chao
Leon Chao
FSFrank Seifert
Frank Seifert
DHDarine Haddad
Darine Haddad
JPJon R Pratt
Jon R Pratt
DNDavid B Newell
David B Newell
SSStephan Schlamminger
Stephan Schlamminger
A tabletop-sized Kibble balance (KIBB-g1) designed to directly realize mass at the gram-level range with uncertainties on the order of parts in 106 has been developed at the National Institute of Standards and Technology (NIST). The masses of a nominally 5 g and 1 g weight were determined with standard uncertainties of 9.0 g and 6.7 g, respectively. The corresponding relative uncertainties are and . The construction of the instrument, capabilities, and full uncertainty budgets are presented in this manuscript.

1 August 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
RMRafael R. Marangoni
Rafael R. Marangoni
DHDarine Haddad
Darine Haddad
FSFrank Seifert
Frank Seifert
LCLeon S. Chao
Leon S. Chao
DNDavid B. Newell
David B. Newell
SSStephan Schlamminger
Stephan Schlamminger

11 July 2022 in EPJ Techniques and Instrumentation
Verified
Journal Article
Open access
PDF file
LKLorenz Keck
Lorenz Keck
FSFrank Seifert
Frank Seifert
DNDavid Newell
David Newell
SSStephan Schlamminger
Stephan Schlamminger
RTRené Theska
René Theska
DHDarine Haddad
Darine Haddad
The “Quantum Electro-Mechanical Metrology Suite” (QEMMS) is being designed and built at the National Institute of Standards and Technology. It includes a Kibble balance, a graphene quantum Hall resistance array and a Josephson voltage system, so that it is a new primary standard for the unit of mass, the kilogram, directly traceable to the International System of Units (SI) based on quantum constants. We are targeting a measurement range of 10 g to 200 g and optimize the design for a relative combined uncertainty of $2\times 10^{-8}$ 2 × 10 − 8 for masses of 100 g. QEMMS will be developed as an open hardware and software design. In this article, we focus on the design of an enhanced moving and weighing mechanism for the QEMMS based on flexure pivots.

31 December 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
MFMona Feige
Mona Feige
SSStephan Schlamminger
Stephan Schlamminger
AKAndrew D. Koffman
Andrew D. Koffman
DJDean G. Jarrett
Dean G. Jarrett
SPShamith Payagala
Shamith Payagala
YWYicheng Wang
Yicheng Wang
We tested a digital impedance bridge in a hybrid structure for comparison of a capacitor with a resistor where the impedance ratio was measured in two separate parts. The modulus of the impedance ratio was matched arbitrarily close to the input-to-output ratio, in magnitude, of a two-stage inductive voltage divider by adjusting the operating frequency of the bridge; the residual deviation between the two together with the phase factor of the impedance ratio was measured using a custom detection system based on a four-channel 24-bit digitizer. The ratio of the inductive voltage divider was calibrated, in situ, using a conventional four-arm bridge with two known capacitors. Fluctuations of the source voltages were largely removed through postprocessing of the digitized data, and the measurement results were limited by the digitizer error. We have achieved an overall bridge resolution and stability of 0.02 μF/F in 2 hours for measuring a 100 pF capacitor relative to a 12906 Ω resistor at 1233 Hz. The relative combined standard uncertainty (k = 1) is 0.13 μF/F, dominated by the digitizer error.

14 September 2022 in Metrologia
Verified
Journal Article
Open access
PDF file
SSStephan Schlamminger
Stephan Schlamminger
LKLorenz Keck
Lorenz Keck
FSFrank Seifert
Frank Seifert
LCLeon S Chao
Leon S Chao
DHDarine Haddad
Darine Haddad
Shisong LiShisong Li
Shisong Li
Analytically the force acting on a current-carrying coil in a magnetic field can be calculated in two ways. First, a line integral can be conducted along the coil’s wire, summing up the differential force contributions. Each contribution results from a cross-product of the corresponding differential line segment with the magnetic flux density at that location. Alternatively, the coil’s energy in the field is given as a product of three factors, the number of turns, the current, and the flux threading the coil. The energy can then be obtained by executing a surface integral over the coil’s open surface using the scalar product of the differential surface element with the magnetic flux density as its integrand. The force on the coil is the negative derivative of the energy with respect to the appropriate coordinate. For yoke-based Kibble balances, the latter method is much simpler since most of the flux is contained in the inner yoke of the magnet and can be written as a simple equation. Here, we use this method to provide simple equations and their results for finding the torques and forces that act on a coil in a yoke-based magnet system. We further introduce a straightforward method that allows the calculation of the position and orientation difference between the coil and the magnet from three measurements.