Zane Comden

Zane Comden

Auto-generated profile, based on publicly available information

Zane Comden

National Institute of Standards and Technology, Gaithersburg, MD, United States of America

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
ZCZane Comden
Zane Comden
JDJohn Draganov
John Draganov
SSStephan Schlamminger
Stephan Schlamminger
FSFrank Seifert
Frank Seifert
CPCharles Waduwarage Perera
Charles Waduwarage Perera
LCLeon S. Chao
Leon S. Chao
The United States National Institute of Standards and Technology (NIST) has been developing a new device for primary standard realization of torque utilizing established traceability to quantum-electrical standards following the 2019 revision of the International System of Units (SI). This device, the Electronic NIST Torque Realizer (ENTR) is a device directly traceable to the quantum-electrical standards of the revised SI with the goal of outperforming current commercial torque transducer uncertainty levels, improving torque tool calibration at low torque ranges, and shortening the torque standards dissemination chain. This project’s goal is to create a device for torque calibrations with an operational range of 7 × 10 -4 Nm to 1Nm with an uncertainty at or below 0.1 %. We intend ENTR to be a possible replacement for present transfer standards used in the torque standards dissemination chain, easing the financial and logistical burdens of current torque standards dissemination systems.

31 March 2025 in Metrologia
Verified
Journal Article
Open access
LKLorenz Keck
Lorenz Keck
KAKumar Arumugam
Kumar Arumugam
LCLeon Chao
Leon Chao
ZCZane Comden
Zane Comden
FSFrank Seifert
Frank Seifert
SSStephan Schlamminger
Stephan Schlamminger
We revisit the Kibble–Robinson theory, first proposed in 2014 by Kibble and Robinson. This theory significantly simplifies the construction and operation of Kibble balances. We conducted a theoretical investigation of the theory’s assumptions, using a corner cube as the optical target in the interferometer for velocity measurement. We find that it is advantageous to build a mechanism whose output has minimal rotation and horizontal motion. For balances with relative uncertainty targets below 1 × 10 − 6 , the mass pan and the optical target should be suspended from a common gimbal so they have the same vertical velocity and no rotation. In this case, the measurement bias due to Abbe offset is minimized, and the bias due to corner loading is repeatable.

17 September 2025 in Metrologia
Verified
Journal Article
Open access
ZCZane Comden
Zane Comden
SSStephan Schlamminger
Stephan Schlamminger
FSFrank Seifert
Frank Seifert
KAKumar Arumugam
Kumar Arumugam
CSChandra B Shahi
Chandra B Shahi
LCLeon S Chao
Leon S Chao
Calibration of tools designed to apply known torques, such as torque wrenches and torque screwdrivers, requires a chain of traceable standards to the definition of the kilogram and meter derived from the revised International System of Units (SI) via physical mass and length artifact standards. We present a detailed description and experimental verification of a device which utilizes the Kibble principle to directly realize torques up to 1 N m. The second generation Electronic NIST Torque Realizer (ENTR_v2) can calibrate industrial torque tools to 0.1 % accuracy or better ultimately traceable to the fixed value of the Planck constant within the revised SI through electrical traceability chains, severing ties to the traditional physical transfer standard artifacts of length and mass.