View All Publications
21 October 2023 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
AKA. V. Krasnozhon
A. V. Krasnozhon
AKA. O. Kvytsynskyi
A. O. Kvytsynskyi
RBRoman Buinyi
Roman Buinyi
IDI. V. Dihtyaruk
I. V. Dihtyaruk
OKO. V. Krasnozhon
O. V. Krasnozhon
Introduction. The problem of estimating power losses in grounding wires with built-in fiber optic cable for overhead power lines of voltage class 330-750 kV is relevant, while it is obvious that the amount of losses depends on the chosen brand of wire. Problem. In the article, an analysis of the influence of the parameters of grounding wires on the amount of losses that occur in them in the normal mode of operation of the overhead power lines is carried out. Goal. The purpose of the work is to determine the criterion for the selection of grounding wires with a built-in optical fiber cable under the condition of increasing the energy efficiency of electricity transmission. Methodology. To calculate power losses in grounding wires, the methods of electromagnetic field theory were used, while taking into account the location of phase conductors on various types of towers of operating 330-750 kV overhead power lines and the possible current load of such lines. Results. The paper analyzed the dependence of losses in the grounding wires of the overhead power lines on the ratio of its active and reactive resistances, determined in which range of this ratio the losses will be close to the maximum. It is shown that the amount of specific power losses in the grounding wires of 330-750 kV overhead power lines in its normal operating modes can range from 1.6 kW/km for the 750 kV lines to hundreds of W/km for the 330 kV power lines. Originality. For the first time, it is recommended to use grounding wires with built-in fiber optic cable with running active resistance in the range of no more than 0.25 Ohm/km, which will minimize power losses and increase the energy efficiency of the 330-750 kV overhead power lines. Practical value. The obtained results can be applied at the stage of designing new or modernizing existing overhead power lines in order to reduce losses and increase the energy efficiency of lines.

26 December 2020 in Microsystems, Electronics and Acoustics
Verified
Journal Article
Open access
PDF file
ADAndrii Vitaliiovych Dymerets
Andrii Vitaliiovych Dymerets
AKAndrii Vasyliovych Kracnozhon
Andrii Vasyliovych Kracnozhon
OKOleksii Vasyliovych Krasnozhon
Oleksii Vasyliovych Krasnozhon
Моделювання ґратчастого багатошарового екрану для зниження магнітного поля ліній електропередачі

10 February 2026 in TECHNICAL SCIENCES AND TECHNOLOGIES
Verified
Journal Article
Open access
SKSerhii Kovalenko
Serhii Kovalenko
OKOleksii Krasnozhon
Oleksii Krasnozhon
OKOleksandr Khropatyi
Oleksandr Khropatyi
The proposed article is devoted to the study of the architecture of an information system for monitoring data from heat energy meters using Internet of Things (IoT) technologies. The implementation of remote monitoring systems for thermal energy consumption is currently one of the priority directions in energy management aimed at increasing resource efficiency and reducing operational costs. In the face of rising fuel and energy prices, as well as the global necessity to reduce greenhouse gas emissions, heat supply enterprises and facility managers require intelligent tools to control energy usage. The integration of Internet of Things (IoT) technologies allows for the automation of data collection processes, timely detection of accidents, and optimization of heating supply schedules. Therefore, the development of reliable, secure, and scalable information systems for monitoring acts as a critical task for the modernization of municipal infrastructure and the transition to "smart city" concepts. Despite the widespread use of electronic heat meters, a significant problem remains the lack of unified centralized solutions for real-time data collection and analysis. Existing systems often face challenges such as the incompatibility of proprietary protocols from different meter manufacturers, high operational costs of traditional GSM/GPRS communications, and insufficient scalability. Furthermore, ensuring the security of confidential consumer data and processing large volumes of historical information for predictive analytics requires more advanced architectural approaches than those currently available on the market. The objective of this article is to justify and design the architecture of an information system for monitoring data received from heat energy meters based on IoT technology. The system aims to ensure unified data collection from heterogeneous devices, reliable transmission with minimal latency, secure processing, and storage of large data volumes, as well as providing tools for visualization and forecasting of heat consumption. The study proposes a multi-level system architecture consisting of a Device Layer, Gateway Layer, Network Layer, and Application Layer. At the device level, the integration of commercial heat meters with microcontrollers (STM32, ESP32) and additional sensors (DS18B20) is proposed. To ensure energy efficiency and wide coverage, a hybrid communication approach is utilized: LoRaWAN technology is used for long-range transmission (up to 10 km) with low power consumption, while NB-IoT is employed for deep signal penetration in dense urban environments. The system utilizes the MQTT protocol over TLS/DTLS for secure and lightweight data transport. For data processing, a stream processing model (using tools like Apache Kafka) is implemented to filter noise and aggregate readings in real-time. The storage architecture combines Time-series databases (InfluxDB) for high-speed writing of metrological data and NoSQL databases (MongoDB) for managing metadata. The analytical component of the system leverages machine learning algorithms, specifically ARIMA and LSTM models, to forecast heat loads with an accuracy of ±5%, and K-means clustering to detect anomalies such as leaks or unauthorized consumption. The research concludes that the proposed architecture successfully solves the problem of interoperability between different equipment manufacturers through protocol unification. The combination of LoRaWAN and NB-IoT ensures reliable coverage and extends the autonomous operation of sensor nodes up to 30 days. The use of containerization (Docker) ensures the system's scalability to serve tens of thousands of devices. The implementation of predictive analytics allows for the optimization of boiler house operations, potentially reducing energy costs by 8–10%, which confirms the practical value and economic efficiency of the developed system.

27 March 2026 in Bulletin of the National Technical University "KhPI" A series of "Information and Modeling"
Verified
Journal Article
Closed access
DLDenis Lysenok
Denis Lysenok
OKOleksandr Khropatyy
Oleksandr Khropatyy
OKOleksii Krasnozhon
Oleksii Krasnozhon
Unstable electricity supply in Ukraine, including voltage fluctuations and frequent mismatches between planned schedules and real outages, complicates remote work and everyday planning. Smart home solutions also depend on continuous power and network availability, while most existing outage-tracking tools are limited to viewing schedules and do not provide verification of the actual power state at a specific location. Another practical challenge is the fragmentation of telemetry from custom-built IoT devices, because developers often have to implement data collection, storage, and visualisation separately, which increases effort and reduces usability. This paper substantiates the CeroNest approach as an offline-oriented mobile solution that combines access to electricity outage schedules with verification of the actual power supply state using IoT device data, and provides centralised monitoring of indoor microclimate parameters. The objective is to formulate practical requirements for Ukrainian operating conditions and to describe the architecture and interaction principles of CeroNest version 0.4.3, including a lightweight data-exchange convention that simplifies the integration of custom modules and external services. The approach is implemented as a mobile client with local storage and periodic polling of IoT devices within a home network. IoT modules expose telemetry over HTTP and return a unified JSON response, which is normalised into a consistent internal data model. Measurement snapshots and history are stored in a local SQLite database to preserve functionality during connectivity loss. In version 0.4.3, outage schedules are currently obtained only from the Chernihivoblenergo service, weather forecasts are retrieved via the MET Norway API, and settlement names are converted to coordinates using Nominatim. Two reference IoT devices based on ESP8266 are described, including a microclimate module that uses DHT11 and BMP180 sensors and a light-status module that uses an LM393 photosensor. The verification mechanism interprets device availability and telemetry freshness as an indicator of actual power presence at the installation site. The results demonstrate a consolidated workflow for schedules, notifications, microclimate monitoring, and basic verification within a single offline-oriented interface. The integration effort for a new device is reduced to implementing a single JSON-over-HTTP contract and supporting normalisation on the client side. The novelty of the approach lies in combining schedule acquisition, local caching, and power-state verification driven by IoT telemetry within a lightweight extensible architecture suitable for unstable network conditions. Figs.: 7. Tabl.: 1. Refs.: 19 items.

27 May 2026 in TECHNICAL SCIENCES AND TECHNOLOGIES
Verified
Journal Article
Open access
OKOleksii Krasnozhon
Oleksii Krasnozhon
AKAndrii Krasnozhon
Andrii Krasnozhon
DKDmytro Korbach
Dmytro Korbach
OKOleksandr Khropatiy
Oleksandr Khropatiy
The relevance of this article lies in describing the obtaining and analyzing experimental data on the application of HC-11 wireless communication modules inside educational buildings. These data will form the basis for implementing an automated security system for university classrooms as part of the state-registered research work No. 0125U000504. HC-11 wireless modules are based on the CC1101 integrated circuit from Texas Instruments, which provides a wide range of configurable operating parameters. Evidently, parameters, including operating frequency, signal modulation type, transmitter power, and data packet length substantially affect communication quality; therefore, it is necessary to experimentally determine their influence on communication quality, evaluated using three indicators, namely: the arithmetic mean of the received signal strength, packet error rate, and bit error rate. Module configuration and communication quality assessment were performed in the SmartRF Studio environment provided by the manufacturer. The purpose of this article is to describe the experiments and analyze the obtained data to identify the optimal operating parameter sets for HC-11 modules in an automated security system. The article outlines the experimental procedure and available analysis of results using HC-11 modules on the eighth floor of Building IV at Chernihiv Polytechnic National University. Similar experiments were conducted for modules placed on the 9th and 6th floors of the same building. Additionally, the impact of signal modulation type on communication quality was experimentally verified. The arithmetic mean was used to evaluate the communication quality parameters. The conclusions provide the optimal operating parameter sets for HC-11 modules both within a single floor and across multiple floors, along with specific operational features identified during the experiments.

8 August 2025 in TECHNICAL SCIENCES AND TECHNOLOGIES
Verified
Journal Article
Open access
PDF file
SKSergiy Kovalenko
Sergiy Kovalenko
OKOleksii Krasnozhon
Oleksii Krasnozhon
Solving the problem of user identification of computer systems and networks is very relevant, as it allows to increase the level of security, especially when accessing critical data. There are both traditional identification methods (passwords, biomet-rics) and more modern ones.This review article examines existing methods of user identification based on the dynamics of keystrokes. In particular, such methods as dynamic analysis of keystroke times, statistical models for recognizing printing patterns, and neural network approaches to user identification are considered.Dynamic analysis of keystroke times is based on measuring the time characteristics of printing, including the average interval between keystrokes and the duration of holding down keys. These parameters are unique for each user and can be used for authentication.Statistical models for recognizing printing patterns analyze sequences of characters typed at a certain speed and in a certain order. These models help to detect individual text input patterns, which helps to verify users.Approaches based on the use of artificial neural networks use deep learning to process large sets of statistical data on keystrokes. These methods allow the development of complex, multi-layered models for analyzing behavioral characteristics of typing, increasing the accuracy of identification.Thus, we can conclude that none of the methods considered in the article is exhaustive and cannot guarantee 100% correct user identification results. Only by integrating dynamic analysis, statistical modeling and neural network algorithms can we significantly improve authentication security, reducing the risk of unauthorized access and ensuring reliable user iden-tification in information systems.