Low-field (0.55T) magnetic resonance imaging (MRI) may allow MRI-guided interventions using available catheterization equipment, as radiofrequency-induced heating of interventional devices is reduced at low field. The purpose of this study was to test the feasibility of real-time MRI-guided right and left heart catheterization (R&LHC) as well as angioplasty and stenting of the inferior vena cava using a commercially available 0.55T MRI system (MAGNETOM Free.Max, Siemens Healthineers AG, Erlangen, Germany) with 80 cm patient bore and maximum gradient amplitude and slew rate of 26 mT/m and 45 mT/m/ms, respectively. A secondary aim was to evaluate three different sizes of magnetic resonance (MR)-visible markers. Sheaths were placed in the femoral vein and artery of juvenile Yorkshire pigs under general anesthesia. Air-filled balloon wedge catheters and Judkins right catheters were used for R&LHC, respectively, aided by an MR-compatible guidewire. Ferumoxytol was administered as a T1-shortening contrast agent and real-time visualization was carried out with a research interactive sequence using different spatiotemporal resolution settings. IVC angioplasty was performed using balloons filled with 1% gadolinium, and IVC stenting was performed with stainless-steel stents and one platinum-iridium-covered sten. RHC was successful in all eight attempts with balloon tip visibility in all real-time protocols. One pig expired with ferumoxytol infusion, but the catheterization was completed post-mortem. LHC and IVC angioplasty were attempted and successful in two and four pigs, respectively. For stenting, higher resolution, lower frame rate imaging was used. All six attempted stent implantations were successful. The MR markers on the angioplasty balloon with widths of 0.5 and 1 mm were more visible than the 0.25 mm markers. Marker placement affected distinguishability from the crimped stent. Stainless-steel stents created only minimal signal voids pre- and post-deployment; however, the platinum-iridium stent caused significant artifact obscuring wall apposition assessment. This study is the first to demonstrate the technical feasibility of R&LHC, IVC angioplasty, and IVC stenting using real-time MRI on a commercially available low-field scanner.
Image artifacts caused by metal knee implants in 1.5T and 3T magnetic resonance imaging (MRI) systems complicate imaging-based diagnosis of the peri-implant region after total knee arthroplasty. Alternatively, metal-free knee prostheses could effectively minimize MRI safety hazards and offer the potential for higher quality diagnostic images. A novel knee arthroplasty device composed of BIOLOX delta, an alumina matrix composite (AMC) ceramic, was tested in a magnetic resonance (MR) environment. American Society for Testing and Materials test methods were used for evaluating magnetically induced displacement force, magnetically induced torque, radiofrequency-induced heating, and MR image artifact. Magnetically induced displacement force and magnetically induced torque results of the AMC ceramic knee indicated that these effects do not pose a known risk in a clinical MR environment, as assessed in a 3T magnetic field. Moreover, minimal radiofrequency-induced heating of the device was observed. In addition, the AMC ceramic knee demonstrated minimal MR image artifacts (7 mm) in comparison to a cobalt-chromium knee (88 mm). The extremely low magnetic susceptibility of AMC (2 ppm) underlines that it is a nonmetallic and nonmagnetic material well suited for the manufacturing of MR Safe orthopaedic implants. The AMC ceramic knee is a novel metal-free total knee arthroplasty device that can be regarded as MR Safe, as suggested by the absence of hazards from the exposure of this implant to a MR environment. The AMC ceramic knee presents the advantage of being scanned with superior imaging results in 3T MRI systems compared to alternative metal implants on the market.
Magnetic resonance imaging (MRI) is a widely used imaging modality that is ideally suited for imaging soft tissues. The use of strong magnetic and electric fields employed in MRI creates the potential for hazards when imaging patients with metallic implants. With the proper material selection, implant design, and imaging procedure, many of these hazards can be adequately managed. Magnetic susceptibility (χ) is a material property indicating a material’s tendency to interact with and distort an applied magnetic field, and it has substantial influence on both the force and torque experienced by an implant in a magnetic field, as well as the size of the image artifact. In this study, the magnetic susceptibilities of 45 different medically relevant alloys and alloy composites are determined and reported. This data will aid in material selection for medical devices intended to be labeled as MR Conditional.
26 October 2023 in Biomedical Physics & Engineering Express
Purpose. The goal of this study was to develop and validate a computational model that can accurately predict the influence of flow on the temperature rise near a peripheral vascular stent during magnetic resonance imaging (MRI). Methods. Computational modeling and simulation of radio frequency (RF) induced heating of a vascular stent during MRI at 3.0 T was developed and validated with flow phantom experiments. The maximum temperature rise of the stent was measured as a function of physiologically relevant flow rates. Results. A significant difference was not identified between the experiment and simulation (P > 0.05). The temperature rise of the stent during MRI was over 10 °C without flow, and was reduced by 5 °C with a flow rate of only 58 ml min−1, corresponding to a reduction of CEM43 from 45 min to less than 1 min. Conclusion. The computer model developed in this study was validated with experimental measurements, and accurately predicted the influence of flow on the RF-induced temperature rise of a vascular stent during MRI. Furthermore, the results of this study demonstrate that relatively low flow rates significantly reduce the temperature rise of a stent and the surrounding medium during RF-induced heating under typical scanning power and physiologically relevant conditions.
17 September 2025 in Journal of Magnetic Resonance Imaging
Background: Permanent magnet implants are used with several medical and assistive devices, such as cochlear implants, dental attachments, and prosthetic control, but raise caution for MR imaging. Previous work has evaluated several magnet implants for position and magnetization stability, as well as for image artifacts under MRI. Yet, the intramuscular magnets used for prosthetic control still require evaluation for potential MRI conditionality. Purpose: To investigate the position and magnetization stability of and image artifacts from 3‐mm‐diameter spherical permanent magnets ( Br = 1.393 T, Hci = 1.637 MA/m) implanted within muscle. Study Type: Prospective longitudinal study. Animal Model: Porcine; one animal, eight muscles. Field Strength/Sequence: 0.55‐T, 1.5‐T/SE, GRE. Assessment: Permanent magnets and nonmagnetic controls were implanted into eight muscles and exposed to 1.5‐T MRI 36 days post‐implantation. All sites were examined histologically for evidence of implant migration (acute fibrotic response or fibrotic capsule disruption). Benchtop studies evaluated worst‐case demagnetization and image artifacts (artifact radius minus implant radius). The primary measure of position stability was histological examination interpreting characteristics of progressive skeletal muscle healing. Secondary position stability analysis was performed via CT imaging. Statistical Tests: Unpaired one‐sided sign test with a significance level of 0.05. Demagnetization and imaging artifacts were summarized as maximums. Results: Fibrotic capsules were similarly intact at permanent magnet and control sites (fibrotic capsule thicknesses: 20–550 μm [magnets], 20–220 μm [controls]). No effect of MRI exposure on implant migration was observed via secondary analysis ( p = 0.965 [0.55‐T], p = 0.996 [1.5‐T]). Maximum demagnetization was 2.1% under 0.55‐T exposure and 13.5% under 1.5‐T exposure, and maximum image artifact was 71 mm at both imaging strengths. Data Conclusion: The permanent magnet implants used in this study were resistant to migration and substantial demagnetization under 0.55‐T and 1.5‐T MRI exposure and resulted in negligible image artifacts for critical organ imaging, suggesting that the presence of these implants does not preclude a patient from receiving MR imaging up to 1.5T. Evidence Level: N/A. Technical Efficacy: Stage 5: Improvements in patient care.