Alessandro Alan Porporati

Dr. Alessandro Alan Porporati

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
TNThu M. Nguyen
Thu M. Nguyen
LWLydia Weitzler
Lydia Weitzler
CEChristina I. Esposito
Christina I. Esposito
APAlessandro Alan Porporati
Alessandro Alan Porporati
DPDouglas E. Padgett
Douglas E. Padgett
TWTimothy M. Wright
Timothy M. Wright

14 October 2021 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
APAlessandro Alan Porporati
Alessandro Alan Porporati
Laurent GremillardLaurent Gremillard
Laurent Gremillard
Jérôme ChevalierJérôme Chevalier
Jérôme Chevalier
RPRocco Pitto
Rocco Pitto
Marco DelucaMarco Deluca
Marco Deluca
Recent studies on zirconia-toughened alumina (ZTA) evidenced that in vivo aged implants display a much higher monoclinic zirconia content than expected from in vitro simulations by autoclaving. At the moment, there is no agreement on the source of this discrepancy: Some research groups ascribe it to the effect of mechanical impact shocks, which are generally not implemented in standard in vitro aging or hip walking simulators. Others invoke the effect of metal transfer, which should trigger an autocatalytic reaction in the body fluid environment, accelerating the kinetics of tetragonal-to-monoclinic transformation in vivo. Extrapolations of the aging kinetics from high (autoclave) to in vivo temperature are also often disputed. Last, Raman spectroscopy is by far the preferred method to quantify the amount of monoclinically transformed zirconia. There are, however, many sources of errors that may negatively affect Raman results, meaning that the final interpretation might be flawed. In this work, we applied Raman spectroscopy to determine the monoclinic content in as-received and in vitro aged ZTA hip joint implants, and in one long-term retrieval study. We calculated the monoclinic content with the most used equations in the literature and compared it with the results of X-ray diffraction obtained on a similar probe depth. Our results show, contrary to many previous studies, that the long-term surface stability of ZTA ceramics is preserved. This suggests that the Raman technique does not offer consistent and unique results for the analysis of surface degradation. Moreover, we discuss here that tetragonal-to-monoclinic transformation is also necessary to limit contact damage and wear stripe extension. Thus, the surface metastability of zirconia-containing ceramics may be a non-issue.

23 July 2023 in Arthroplasty Today
Verified
Journal Article
Open access
DMDr. Yvonne Mödinger
Dr. Yvonne Mödinger
EAEric D. Anttila
Eric D. Anttila
GBGrant M. Baker
Grant M. Baker
DGDavid C. Gross
David C. Gross
APAlessandro Alan Porporati
Alessandro Alan Porporati
Image artifacts caused by metal knee implants in 1.5T and 3T magnetic resonance imaging (MRI) systems complicate imaging-based diagnosis of the peri-implant region after total knee arthroplasty. Alternatively, metal-free knee prostheses could effectively minimize MRI safety hazards and offer the potential for higher quality diagnostic images. A novel knee arthroplasty device composed of BIOLOX delta, an alumina matrix composite (AMC) ceramic, was tested in a magnetic resonance (MR) environment. American Society for Testing and Materials test methods were used for evaluating magnetically induced displacement force, magnetically induced torque, radiofrequency-induced heating, and MR image artifact. Magnetically induced displacement force and magnetically induced torque results of the AMC ceramic knee indicated that these effects do not pose a known risk in a clinical MR environment, as assessed in a 3T magnetic field. Moreover, minimal radiofrequency-induced heating of the device was observed. In addition, the AMC ceramic knee demonstrated minimal MR image artifacts (7 mm) in comparison to a cobalt-chromium knee (88 mm). The extremely low magnetic susceptibility of AMC (2 ppm) underlines that it is a nonmetallic and nonmagnetic material well suited for the manufacturing of MR Safe orthopaedic implants. The AMC ceramic knee is a novel metal-free total knee arthroplasty device that can be regarded as MR Safe, as suggested by the absence of hazards from the exposure of this implant to a MR environment. The AMC ceramic knee presents the advantage of being scanned with superior imaging results in 3T MRI systems compared to alternative metal implants on the market.

1 January 2023
Verified
Book
Closed access
ARArmando Reyes Reyes-Rojas
Armando Reyes Reyes-Rojas
AAAlfredo Aguilar-Elguezabal
Alfredo Aguilar-Elguezabal
APAlessandro Alan Porporati
Alessandro Alan Porporati
MBMiguel Humberto Bocanegra-Bernal
Miguel Humberto Bocanegra-Bernal
Hilda Esperanza Esparza-PonceHilda Esperanza Esparza-Ponce
Hilda Esperanza Esparza-Ponce

Verified
Journal Article
Open access
PDF file
APAlessandro Alan Porporati
Alessandro Alan Porporati
DMDr. Yvonne Mödinger
Dr. Yvonne Mödinger
SFSarah Fischer
Sarah Fischer
SPSara Polajžer
Sara Polajžer
MMMelanie Mettang
Melanie Mettang
MLMarija Nika Lovsin
Marija Nika Lovsin
Ten percent of patients undergoing total hip arthroplasty (THA) require revision surgery. One of the reasons for THA are wear particles released from the implants that can activate the immune defense and cause osteolysis and failure of the joint implant. The discrepancies between reports on toxicity and immunogenicity of the implant materials led us to this study in which we compared toxicity and immunogenicity of well-defined nanoparticles from Al2O3, zirconia-toughened alumina (ZTA), and cobalt chrome (CoCr), a human THP-1 macrophage cell line, human PBMCs, and therefrom-derived primary macrophages. None of the tested materials decreased the viability of THP-1 macrophages nor human primary macrophages at the 24 h time point, indicating that at concentrations from 0.05 to 50 µm3/cell the tested materials are non-toxic. Forty-eight hours of treatment of THP-1 macrophages with 5 µm3/cell of CoCr and Al2O3 caused 8.3-fold and 4.6-fold increases in TNF-α excretion, respectively, which was not observed for ZTA. The comparison between THP-1 macrophages and human primary macrophages revealed that THP-1 macrophages show higher activation of cytokine expression in the presence of CoCr and Al2O3 particles than primary macrophages. Our results indicate that ZTA is a non-toxic implant material with no immunogenic effects in vitro.

1 January 2022 in Clinics in Orthopedic Surgery
Verified
Journal Article
Open access
PDF file
HKHong Seok Kim
Hong Seok Kim
JPJung-Wee Park
Jung-Wee Park
YLYoung-kyun Lee
Young-kyun Lee
APAlessandro Alan Porporati
Alessandro Alan Porporati
YHYong-Chan Ha
Yong-Chan Ha
KKKyung-Hoi Koo
Kyung-Hoi Koo
Kim HS, et al. Clin Orthop Surg. 2022 Jun;14(2):191-195. https://doi.org/10.4055/cios21102