27 June 2022 in IEEE Access
Recent technological advancements such as an expansion of available biomarkers and an incremental burden of chronic and infectious diseases made point of care (POC) devices in strong demand. It has a potential to surpass conventional lab-based devices in terms of time, cost, accessibility, and even accuracy. This potential strongly depends on an availability of affordable and miniaturized electronic POC devices that can provide a fast and sensitive response. This paper presents an all-in-one electroanalytical device (AED) which is a cost-effective, field-ready, and miniaturized electronic POC device integrated with the most commonly used electroanalytical techniques such as amperometric, voltammetric, potentiometric, conductometric, and impedimetric techniques. The proposed AED can analyze multiple electrochemical sensors simultaneously while having a very small size of 48 mm $\times37$ mm, including eight disposable screen-printed electrochemical sensor (SPES) connectors. The device supports wired communication using a universal serial bus (USB) and wireless communication with Bluetooth Low Energy (BLE). Furthermore, user-friendly customized Graphical User Interface (GUI) has been developed to control the device and send obtained data to the user. The system is evaluated through electrical tests to confirm the device accuracy. Subsequently, electrochemical experiments were conducted to evaluate device’s performance in the field. These experiments indicated that the developed device operates as an electrochemical sensing device for POC applications. The proposed portable electroanalytical device can perform the most of electroanalytical methods in a single device which has very small form factor and capability to interpret multiple sensors at a time with user friendly interface.
25 April 2022 in IEEE Access
This paper aims at designing a compact readout system for chemiresistive sensor array with high speed and high accuracy. The proposed scheme is based on Resistance-to-Voltage (R-V) conversion and targets high density wide ranged chemiresistive sensor, with input resistance range of 1 KΩ - 1 MΩ and 0.1 % sensitivity. The proposed approach uses Adaptive Reference Resistor Tuning (ARRT) technique implemented with a digital variable potentiometer to achieve a high accuracy without sacrificing the dynamic range and the speed. The system is implemented on a printed circuit board with a microcontroller and a 16-bit Analog-to-Digital Converter (ADC), and it has a compact dimension of 10 cm × 6 cm, which is suitable for portable applications. The readout system works with a 5 V power supply, and the overall system power consumption is 150 mW. The system is designed to interface with a 118 sensor array and the experimental results achieved a satisfactory accuracy of 0.88 %, as well as a measuring speed of 8.5 ms per sensor. Compared with existing approaches, our work targets a high density wide ranged chemiresistive sensor array and demonstrated high accuracy, high speed with the lowest circuit complexity, which is the novelty of this work.