Sungyong Jung

Dr. Sungyong Jung

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2006
Verified
Conference Paper
Closed access
HKHyunseok Kim
Hyunseok Kim
YJYoungjoong Joo
Youngjoong Joo
SJSungyong Jung
Sungyong Jung
A tunable ultra-wideband (UWB) pulse generator is designed and simulated with standard 0.18 mum CMOS technology. By using a voltage controlled delay line (VCDL) technique, the proposed UWB pulse generator can adjust the pulse width, adding flexibility for use with different UWB applications. Moreover, each peak of the proposed UWB pulse is separately controlled so that it complies with the FCC regulation. The proposed UWB pulse generator achieves the fifth-order derivative of the Gaussian pulse and can tune the pulse width from 0.38-ns to 4-ns. In particular, the maximum and minimum pulse widths comply with 3-10 GHz and sub-GHz FCC regulations, respectively

27 June 2022 in IEEE Access
Verified
Journal Article
Open access
HPHyusim Park
Hyusim Park
YPYounghun Park
Younghun Park
SLShanthala Lakshminarayana
Shanthala Lakshminarayana
HJHyun-Min Jung
Hyun-Min Jung
MKMin-Yeong Kim
Min-Yeong Kim
SJSungyong Jung
Sungyong Jung
Recent technological advancements such as an expansion of available biomarkers and an incremental burden of chronic and infectious diseases made point of care (POC) devices in strong demand. It has a potential to surpass conventional lab-based devices in terms of time, cost, accessibility, and even accuracy. This potential strongly depends on an availability of affordable and miniaturized electronic POC devices that can provide a fast and sensitive response. This paper presents an all-in-one electroanalytical device (AED) which is a cost-effective, field-ready, and miniaturized electronic POC device integrated with the most commonly used electroanalytical techniques such as amperometric, voltammetric, potentiometric, conductometric, and impedimetric techniques. The proposed AED can analyze multiple electrochemical sensors simultaneously while having a very small size of 48 mm $\times37$ mm, including eight disposable screen-printed electrochemical sensor (SPES) connectors. The device supports wired communication using a universal serial bus (USB) and wireless communication with Bluetooth Low Energy (BLE). Furthermore, user-friendly customized Graphical User Interface (GUI) has been developed to control the device and send obtained data to the user. The system is evaluated through electrical tests to confirm the device accuracy. Subsequently, electrochemical experiments were conducted to evaluate device’s performance in the field. These experiments indicated that the developed device operates as an electrochemical sensing device for POC applications. The proposed portable electroanalytical device can perform the most of electroanalytical methods in a single device which has very small form factor and capability to interpret multiple sensors at a time with user friendly interface.

25 April 2022 in IEEE Access
Verified
Journal Article
Open access
SLShanthala Lakshminarayana
Shanthala Lakshminarayana
YPYounghun Park
Younghun Park
HPHyusim Park
Hyusim Park
SJSungyong Jung
Sungyong Jung
This paper aims at designing a compact readout system for chemiresistive sensor array with high speed and high accuracy. The proposed scheme is based on Resistance-to-Voltage (R-V) conversion and targets high density wide ranged chemiresistive sensor, with input resistance range of 1 KΩ - 1 MΩ and 0.1 % sensitivity. The proposed approach uses Adaptive Reference Resistor Tuning (ARRT) technique implemented with a digital variable potentiometer to achieve a high accuracy without sacrificing the dynamic range and the speed. The system is implemented on a printed circuit board with a microcontroller and a 16-bit Analog-to-Digital Converter (ADC), and it has a compact dimension of 10 cm × 6 cm, which is suitable for portable applications. The readout system works with a 5 V power supply, and the overall system power consumption is 150 mW. The system is designed to interface with a 118 sensor array and the experimental results achieved a satisfactory accuracy of 0.88 %, as well as a measuring speed of 8.5 ms per sensor. Compared with existing approaches, our work targets a high density wide ranged chemiresistive sensor array and demonstrated high accuracy, high speed with the lowest circuit complexity, which is the novelty of this work.

1 March 2023 in ECS Sensors Plus
Verified
Journal Article
Open access
PDF file
HPHyusim Park
Hyusim Park
LNLiem Huu Trong Nguyen
Liem Huu Trong Nguyen
SLShanthala Lakshminarayana
Shanthala Lakshminarayana
YSYuze Sun
Yuze Sun
SJSungyong Jung
Sungyong Jung
Wearable devices can be found as numerous types of health devices ranging from monitoring hazardous environments to detecting physiological signals. Its utilities have also shown encouraging improvements toward personalized healthcare. Thus, many kinds of wearable health devices (WHD) have been reported and developed. Those reports highlight their efficiency in monitoring harmful environmental factors and various diseases for diagnostic and treatment purposes. This paper proposes a watch-type of dual-mode WHD that can perform gaseous phase detection to monitor dangerous environmental situations such as bad air quality and aqueous phase detection to measure physiological signals from human sweat or blood. The proposed system was fabricated on a printed circuit board and its size is 3 cm × 3 cm which is suitable as a wearable device. It also consumes very low power and has capabilities of wired/wireless charging and wired/wireless communication. Furthermore, customized windows and Android applications have been developed to visualize obtained data in a user’s computer or smartphone. The system was tested both electrically and chemically and showed promising results as the WHD.

27 April 2025 in Electronics
Verified
Journal Article
Open access
PDF file
SLSheng Lu
Sheng Lu
LSLiuting Shang
Liuting Shang
QQQianhou Qu
Qianhou Qu
SJSungyong Jung
Sungyong Jung
QLQilian Liang
Qilian Liang
Chenyun PanChenyun Pan
Chenyun Pan
The use of multi-output look-up tables (LUTs) is a widely adopted approach in contemporary commercial field-programmable gate arrays (FPGAs). Larger LUT configurations (e.g., six-input LUTs) can be partitioned into smaller LUTs (e.g., two five-input LUTs, maintaining a total input count of less than six). This capability of generating a second output from a larger LUT is not only crucial for reducing logic cell count and enhancing the utilization efficiency of logic resources—thus conserving area—but also plays a key role in optimizing system-level delays and energy consumption. In this paper, we propose an efficient multi-output LUT mapping technique, incorporating several highly efficient technology mapping algorithms, which focus on optimizing the mapping from an interconnection perspective as alternatives to directly merging smaller LUTs. These algorithms include a side-fanout insertion algorithm, and a runtime multi-output cut generation algorithm. The proposed methods improve mapping efficiency and enhance performance. The benchmarking results demonstrate that the dual-output mapping algorithms achieve LUT area reductions of up to 35% and 6%, compared to the state-of-the-art ABC six-input, single-output LUT mapping technique and previous work focusing on dual-output LUT mapping techniques that optimize cut generation parameters. Moreover, FPGA system-level simulations also show that area, delay, and energy can all be optimized based on this multi-output mapping technique.

27 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SLShanthala Lakshminarayana
Shanthala Lakshminarayana
YPYounghun Park
Younghun Park
HPHyusim Park
Hyusim Park
SJSungyong Jung
Sungyong Jung
This work presents a wearable sensing system for high-density resistive array readout. The system comprising readout electronics for a high-density resistive sensor array and a rechargeable battery, was realized in a wristband. The analyzed data with the proposed system can be visualized using a custom graphical user interface (GUI) developed in a personal computer (PC) through a universal serial bus (USB) and using an Android app in smartphones via Bluetooth Low Energy (BLE), respectively. The readout electronics were implemented on a printed circuit board (PCB) and had a compact dimension of 3 cm × 3 cm. It was designed to measure the resistive sensor with a dynamic range of 1 KΩ–1 MΩ and detect a 0.1% change of the base resistance. The system operated at a 5 V supply voltage, and the overall system power consumption was 95 mW. The readout circuit employed a resistance-to-voltage (R-V) conversion topology using a 16-bit analog-to-digital converter (ADC), integrated in the Cypress Programmable System-on-Chip (PSoC®) 5LP microcontroller. The device behaves as a universal-type sensing system that can be interfaced with a wide variety of resistive sensors, including chemiresistors, piezoresistors, and thermoelectric sensors, whose resistance variations fall in the target measurement range of 1 KΩ–1 MΩ. The system performance was tested with a 60-resistor array and showed a satisfactory accuracy, with a worst-case error rate up to 2.5%. The developed sensing system shows promising results for applications in the field of the Internet of things (IoT), point-of-care testing (PoCT), and low-cost wearable devices.