Hyusim Park

Dr. Hyusim Park

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2022 in IEEE Access
Verified
Journal Article
Open access
HPHyusim Park
Hyusim Park
YPYounghun Park
Younghun Park
SLShanthala Lakshminarayana
Shanthala Lakshminarayana
HJHyun-Min Jung
Hyun-Min Jung
MKMin-Yeong Kim
Min-Yeong Kim
SJSungyong Jung
Sungyong Jung
Recent technological advancements such as an expansion of available biomarkers and an incremental burden of chronic and infectious diseases made point of care (POC) devices in strong demand. It has a potential to surpass conventional lab-based devices in terms of time, cost, accessibility, and even accuracy. This potential strongly depends on an availability of affordable and miniaturized electronic POC devices that can provide a fast and sensitive response. This paper presents an all-in-one electroanalytical device (AED) which is a cost-effective, field-ready, and miniaturized electronic POC device integrated with the most commonly used electroanalytical techniques such as amperometric, voltammetric, potentiometric, conductometric, and impedimetric techniques. The proposed AED can analyze multiple electrochemical sensors simultaneously while having a very small size of 48 mm $\times37$ mm, including eight disposable screen-printed electrochemical sensor (SPES) connectors. The device supports wired communication using a universal serial bus (USB) and wireless communication with Bluetooth Low Energy (BLE). Furthermore, user-friendly customized Graphical User Interface (GUI) has been developed to control the device and send obtained data to the user. The system is evaluated through electrical tests to confirm the device accuracy. Subsequently, electrochemical experiments were conducted to evaluate device’s performance in the field. These experiments indicated that the developed device operates as an electrochemical sensing device for POC applications. The proposed portable electroanalytical device can perform the most of electroanalytical methods in a single device which has very small form factor and capability to interpret multiple sensors at a time with user friendly interface.

25 April 2022 in IEEE Access
Verified
Journal Article
Open access
SLShanthala Lakshminarayana
Shanthala Lakshminarayana
YPYounghun Park
Younghun Park
HPHyusim Park
Hyusim Park
SJSungyong Jung
Sungyong Jung
This paper aims at designing a compact readout system for chemiresistive sensor array with high speed and high accuracy. The proposed scheme is based on Resistance-to-Voltage (R-V) conversion and targets high density wide ranged chemiresistive sensor, with input resistance range of 1 KΩ - 1 MΩ and 0.1 % sensitivity. The proposed approach uses Adaptive Reference Resistor Tuning (ARRT) technique implemented with a digital variable potentiometer to achieve a high accuracy without sacrificing the dynamic range and the speed. The system is implemented on a printed circuit board with a microcontroller and a 16-bit Analog-to-Digital Converter (ADC), and it has a compact dimension of 10 cm × 6 cm, which is suitable for portable applications. The readout system works with a 5 V power supply, and the overall system power consumption is 150 mW. The system is designed to interface with a 118 sensor array and the experimental results achieved a satisfactory accuracy of 0.88 %, as well as a measuring speed of 8.5 ms per sensor. Compared with existing approaches, our work targets a high density wide ranged chemiresistive sensor array and demonstrated high accuracy, high speed with the lowest circuit complexity, which is the novelty of this work.

1 March 2023 in ECS Sensors Plus
Verified
Journal Article
Open access
PDF file
HPHyusim Park
Hyusim Park
LNLiem Huu Trong Nguyen
Liem Huu Trong Nguyen
SLShanthala Lakshminarayana
Shanthala Lakshminarayana
YSYuze Sun
Yuze Sun
SJSungyong Jung
Sungyong Jung
Wearable devices can be found as numerous types of health devices ranging from monitoring hazardous environments to detecting physiological signals. Its utilities have also shown encouraging improvements toward personalized healthcare. Thus, many kinds of wearable health devices (WHD) have been reported and developed. Those reports highlight their efficiency in monitoring harmful environmental factors and various diseases for diagnostic and treatment purposes. This paper proposes a watch-type of dual-mode WHD that can perform gaseous phase detection to monitor dangerous environmental situations such as bad air quality and aqueous phase detection to measure physiological signals from human sweat or blood. The proposed system was fabricated on a printed circuit board and its size is 3 cm × 3 cm which is suitable as a wearable device. It also consumes very low power and has capabilities of wired/wireless charging and wired/wireless communication. Furthermore, customized windows and Android applications have been developed to visualize obtained data in a user’s computer or smartphone. The system was tested both electrically and chemically and showed promising results as the WHD.

27 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SLShanthala Lakshminarayana
Shanthala Lakshminarayana
YPYounghun Park
Younghun Park
HPHyusim Park
Hyusim Park
SJSungyong Jung
Sungyong Jung
This work presents a wearable sensing system for high-density resistive array readout. The system comprising readout electronics for a high-density resistive sensor array and a rechargeable battery, was realized in a wristband. The analyzed data with the proposed system can be visualized using a custom graphical user interface (GUI) developed in a personal computer (PC) through a universal serial bus (USB) and using an Android app in smartphones via Bluetooth Low Energy (BLE), respectively. The readout electronics were implemented on a printed circuit board (PCB) and had a compact dimension of 3 cm × 3 cm. It was designed to measure the resistive sensor with a dynamic range of 1 KΩ–1 MΩ and detect a 0.1% change of the base resistance. The system operated at a 5 V supply voltage, and the overall system power consumption was 95 mW. The readout circuit employed a resistance-to-voltage (R-V) conversion topology using a 16-bit analog-to-digital converter (ADC), integrated in the Cypress Programmable System-on-Chip (PSoC®) 5LP microcontroller. The device behaves as a universal-type sensing system that can be interfaced with a wide variety of resistive sensors, including chemiresistors, piezoresistors, and thermoelectric sensors, whose resistance variations fall in the target measurement range of 1 KΩ–1 MΩ. The system performance was tested with a 60-resistor array and showed a satisfactory accuracy, with a worst-case error rate up to 2.5%. The developed sensing system shows promising results for applications in the field of the Internet of things (IoT), point-of-care testing (PoCT), and low-cost wearable devices.

8 April 2022 in Electronics
Verified
Journal Article
Open access
PDF file
HPHyusim Park
Hyusim Park
SLShanthala Lakshminarayana
Shanthala Lakshminarayana
Chenyun PanChenyun Pan
Chenyun Pan
HCHoon-Ju Chung
Hoon-Ju Chung
SJSungyong Jung
Sungyong Jung
The objective of this work was to design a versatile readout circuit for patch-type wearable devices consisting of a Transimpedance Amplifier (TIA). The TIA performs Current to Voltage (I–V) conversion, the most widely used technique for amperometry and impedance measurement for various types of electrochemical sensors. The proposed readout circuit employs a digitally controllable feedback resistor (Rf) technique in the TIA to improve accuracy, which can be utilized in a variety of electrochemical sensors within a current range of 0.1 µA–100 µA. It is designed to accommodate multiple sensors simultaneously to track multiple target analytes for high accuracy and versatile usage. The readout circuit consists of low power operational amplifier (op–amp) and digital circuit blocks, is designed and fabricated with Magna 0.18 µm Complementary Metal Oxide Semiconductor (CMOS) technology, which provides low power consumption and a high degree of integration. The design has a small size of 0.282 mm2 and low power consumption of 0.38 mW with a 3.3 V power supply, which are desirable factors in wearable device applications.

11 October 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLShanthala Lakshminarayana
Shanthala Lakshminarayana
MRMrudula Ranganatha
Mrudula Ranganatha
HPHyusim Park
Hyusim Park
SJSungyong Jung
Sungyong Jung
In the domain of healthcare, wearable health monitoring devices have emerged as essential tools for the advancement of patient health tracking. These devices facilitate the provision of real-time medical data to clinicians, enabling early diagnosis, timely intervention, and enhanced management of individual health. This study introduces an innovative trimodal wearable health monitoring device in the form of a wristwatch. The device integrates a breath analyzer for the assessment of gaseous phase biomarkers, a sweat analyzer for the evaluation of aqueous-phase biomarkers, and an infrared sensor for the measurement of body temperature in the optical phase. Engineered on a compact 3 cm × 3 cm printed circuit board, the device has been optimized for wearability, power efficiency, and seamless integration with both wired and wireless charging and communication systems. Furthermore, custom software applications, designed for both Windows and Android platforms, have been developed to facilitate intuitive data visualization and storage on personal computers and smartphones. Empirical results from real-time chemical testing substantiate the device’s efficacy and potential as an advanced solution for wearable health monitoring.