Dave Harber

Dave Harber

Auto-generated profile, based on publicly available information

Dave Harber

Laboratory for Atmospheric and Space Physics University of Colorado Boulder Boulder CO USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2021 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
OCOdele Coddington
Odele Coddington
ERE. C. Richard
E. C. Richard
DHD. Harber
D. Harber
PPP. Pilewskie
P. Pilewskie
TWT. N. Woods
T. N. Woods
KSKang Sun
Kang Sun
We present a new solar irradiance reference spectrum representative of solar minimum conditions between solar cycles 24 and 25. The Total and Spectral Solar Irradiance Sensor‐1 (TSIS‐1) Hybrid Solar Reference Spectrum (HSRS) is developed by applying a modified spectral ratio method to normalize very high spectral resolution solar line data to the absolute irradiance scale of the TSIS‐1 Spectral Irradiance Monitor (SIM) and the CubeSat Compact SIM (CSIM). The high spectral resolution solar line data are the Air Force Geophysical Laboratory ultraviolet solar irradiance balloon observations, the ground‐based Quality Assurance of Spectral Ultraviolet Measurements In Europe Fourier transform spectrometer solar irradiance observations, the Kitt Peak National Observatory solar transmittance atlas, and the semi‐empirical Solar Pseudo‐Transmittance Spectrum atlas. The TSIS‐1 HSRS spans 202–2730 nm at 0.01 to ∼0.001 nm spectral resolution with uncertainties of 0.3% between 460 and 2365 nm and 1.3% at wavelengths outside that range.

3 March 2023 in Earth and Space Science
Verified
Journal Article
Open access
OCOdele Coddington
Odele Coddington
ERE. C. Richard
E. C. Richard
DHD. Harber
D. Harber
PPP. Pilewskie
P. Pilewskie
TWT. N. Woods
T. N. Woods
KSKang Sun
Kang Sun
This work describes two achievements to a key data set. First, we present version 2 of the Total and Spectral Solar Irradiance Sensor‐1 Hybrid Solar Reference Spectrum (TSIS‐1 HSRS), which has recently been recognized as a new solar irradiance reference standard (https://calvalportal.ceos.org/). Second, we present a new “full spectrum extension” of the TSIS‐1 HSRS. The TSIS‐1 HSRS observational composite solar irradiance reference spectrum spans 0.202–2.730 μm and encompasses more than 97% of the energy in the total solar irradiance (TSI). Version 2 is an incremental update that corrects the radiometric baseline between 0.202 and 0.210 μm and updates the solar lines at wavelengths longward of 0.743 μm to those listed in the most recent database. The full spectrum extension builds off version 2 of the TSIS‐1 HSRS and supports applications that require a solar spectrum encompassing nearly 100% of the energy in the TSI. It spans 0.115–200 μm and was developed by incorporating additional observations and theoretical knowledge where no direct observations currently exist.

1 May 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
NTN. A. Tomlin
N. A. Tomlin
CYC. S. Yung
C. S. Yung
ZCZ. Castleman
Z. Castleman
MDM. Denoual
M. Denoual
GDG. Drake
G. Drake
JLJ. H. Lehman
J. H. Lehman
Multi-wall vertically aligned carbon nanotubes (VACNTs) are nearly ideal absorbers due to their exceptionally low reflectance over a broad wavelength range. Integrating VACNTs as bolometer absorbers, however, can be difficult due to their high growth temperature and fragile nature. Despite these challenges, we have microfabricated many different types of VACNT bolometers, ranging from cryogenic optical power primary standards to room temperature satellite-based solar irradiance monitors and broadband infrared microbolometers. Advantages our VACNT bolometers provide over the bolometers they replace vary by application, but can be reduced size and time constant, increased absorption, and/or microfabrication instead of hand assembly. Depending on the application and operating conditions, our VACNT bolometers are designed with a variety of thermistors and weak thermal links. The thermistors used include commercial surface mount chips, superconducting transition-edge sensors, and vanadium oxide (VOx). Weak thermal links include silicon nitride (SiNx) membranes, Si bridges, and laser-cut polyimide. We summarize a wide variety of microfabricated bolometers with VACNT absorbers that measure optical power levels spanning over seven orders of magnitude.

16 August 2022 in Metrologia
Verified
Journal Article
Open access
PDF file
MWMalcolm White
Malcolm White
KHKarl Heuerman
Karl Heuerman
PSPing-Shine Shaw
Ping-Shine Shaw
MSMichelle Stephens
Michelle Stephens
NTN A Tomlin
N A Tomlin
DHDave Harber
Dave Harber
We present the results of a recent, extensive measurement campaign validating the traceability of the solar irradiance record and Earth radiation budget data. The campaign also established future traceability, thus ensuring confidence in the continuing climate-data record. The total solar irradiance radiometer facility (TRF) at the Laboratory for Atmospheric and Space Physics (LASP) Boulder, uses a liquid helium cooled cryogenic radiometer as the reference standard for the validation of spaceflight total solar irradiance (TSI) instrumentation. In 2008 the radiometer was directly compared to the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at a wavelength of 532.12 nm. At TSI power levels, a correction factor of 1.000 306 with an associated standard uncertainty (u) of 0.000 098, was reported for the TRF radiometer scale when using external voltage measurement electronics, and not correcting for cavity heating non-equivalence or cavity absorptance. The TRF radiometer has recently been revalidated at LASP using a POWR calibrated silicon photodiode trap transfer standard named TT4. We report a correction factor of 0.999 787, u = 0.000 285 to align the TRF radiometer scale with the current NIST POWR scale. A new room temperature reference standard radiometer was established. It measured 133 parts per million (ppm) higher than POWR using the same silicon transfer standard as above, and in a separate direct measurement, 168 ppm lower than the TRF radiometer shuttered at 400 s full shutter cycle. The difference agrees within stated uncertainties. A correction of 0.999 867, u = 0.000 247 will align the new radiometer scale with the NIST radiant power scale of POWR.

3 December 2024 in Metrologia
Verified
Journal Article
Open access
JGJ Gieseler
J Gieseler
MWM G White
M G White
DHD Harber
D Harber
RHR Haun
R Haun
NTN A Tomlin
N A Tomlin
JLJ H Lehman
J H Lehman
We present the results of a finite element analysis of the electro-optical non-equivalence of planar electrical substitution radiometers with vertically aligned carbon nanotube absorbers, operating at either room or cryogenic temperature. These detectors are the basis of the new room temperature standards of the Laboratory for Atmospheric and Space Physics’ (LASP) Total solar irradiance Radiometer Facility and the Spectral solar irradiance Radiometer Facility, and the NIST Boulder open beam cryogenic radiometer facility. We show that the detector of our cryogenic electrical substitution radiometer has no significant electro-optical non-equivalence. Further, we also show that with careful detector design, the non-equivalence can be minimized at room temperature. It was found that in general the non-equivalence cannot be deduced from the temperature mismatch between the electrical and the optical states without considering the conductance mismatch and optical power input. The results are regarded as being precise rather than absolute to account for potentially unknown modeling errors. The numerical accuracy is typically less than 5 ppm.

18 December 2025 in Earth and Space Science
Verified
Journal Article
Open access
OCOdele Coddington
Odele Coddington
DHD. Harber
D. Harber
PPPeter Pilewskie
Peter Pilewskie
ERE. Richard
E. Richard
TPT. Patton
T. Patton
The dominant external forcing to Earth's climate system is solar radiation, referred to as the solar spectral irradiance (SSI) and the total solar irradiance (TSI), which is the integral of SSI over all wavelengths. Accurate measurements of TSI and SSI are made from space because solar radiation is absorbed within Earth's atmosphere and that absorption would otherwise need to be corrected for, with added uncertainty, in ground or airborne solar irradiance observations. Composite solar irradiance records, developed from multiple instruments, can represent solar forcing over timescales longer than the lifetime of any individual instrument. We develop a new TSI composite record from pairs of overlapping individual measurement records with the highest relative stability over the longest timescales as determined from Allan Deviation analysis. Allan Deviation is a time‐domain measurement standard analysis technique that was originally established by the metrology community to quantify the stability of atomic clocks. Version 0 of the Time Variance TSI (TV TSI) Composite begins in early 2003 and includes all Total Irradiance Monitor (TIM) instrument records beginning with the NASA Solar Radiation and Climate Experiment (SORCE) mission and continuing through today with the Total and Spectral Solar Irradiance Sensor (TSIS‐1) mission. In future work, we plan to use Allan Deviation analysis to guide the incorporation of additional TSI measurement records and their time‐dependent expression of uncertainties in order to develop a new version of the TV TSI composite that spans an even longer period of time for climate studies.