We present the results of a recent, extensive measurement campaign validating the traceability of the solar irradiance record and Earth radiation budget data. The campaign also established future traceability, thus ensuring confidence in the continuing climate-data record. The total solar irradiance radiometer facility (TRF) at the Laboratory for Atmospheric and Space Physics (LASP) Boulder, uses a liquid helium cooled cryogenic radiometer as the reference standard for the validation of spaceflight total solar irradiance (TSI) instrumentation. In 2008 the radiometer was directly compared to the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at a wavelength of 532.12 nm. At TSI power levels, a correction factor of 1.000 306 with an associated standard uncertainty (u) of 0.000 098, was reported for the TRF radiometer scale when using external voltage measurement electronics, and not correcting for cavity heating non-equivalence or cavity absorptance. The TRF radiometer has recently been revalidated at LASP using a POWR calibrated silicon photodiode trap transfer standard named TT4. We report a correction factor of 0.999 787, u = 0.000 285 to align the TRF radiometer scale with the current NIST POWR scale. A new room temperature reference standard radiometer was established. It measured 133 parts per million (ppm) higher than POWR using the same silicon transfer standard as above, and in a separate direct measurement, 168 ppm lower than the TRF radiometer shuttered at 400 s full shutter cycle. The difference agrees within stated uncertainties. A correction of 0.999 867, u = 0.000 247 will align the new radiometer scale with the NIST radiant power scale of POWR.
In this paper, we briefly describe measurements of the 60 - 200 eV photoemission from Caesium Iodide, Gold, and Aluminum photocathodes made on beamline 6.1 of the SERC Daresbury synchrotron radiation source (SRS). Measurements were made near grazing incidence using both s- (electric vector perpendicular to the plane of incidence) and p- polarized (electric vector parallel to the plane of incidence) radiation. Our data supports the existence of an 'x-ray vectorial effect'--a pronounced linear polarization dependence of the photoyield--observed in earlier experiments at Leicester and Columbia Universities and elsewhere. For CsI, novel measurements are also reported of: radiation damage and annealing, and the temperature dependence of the photoyield.
We report a measurement of the total photoelectron yield of gold as a function of the incident x-ray polarization. Polarized x rays with energies of 2.5, 2.7, and 4.0 keV were used to excite a gold photocathode at a glancing incidence angle between 5° and 50°. Contrary to a previous report, we found no measurable polarization dependence for all three x-ray energies. We conclude that the modulation factor, i.e., the fractional change of the total yield when the polarization state is varied, is less than 4%.
Heat transport modelling of a planar absolute detector with vertically aligned carbon nanotube absorbers has been applied to the newly developed ambient-temperature electrical substitution radiometer (ESR), NACR8. Integrated into the Laboratory for Atmospheric and Space Physics (LASP) Total-solar-irradiance Radiometer Facility (TRF) NACR8 operates as an absolute optical power reference standard supporting validation of satellite based solar irradiance measurements, including those from the TSIS 2 TIM instrument. The modelling enables estimation and correction for electro-optical non-equivalence and its associated uncertainty, providing a generalised method applicable to planar thermal detectors. This approach represents an advancement in the understanding and correction of radiometric non-equivalence in optical radiation metrology. Traceability and performance of NACR8, incorporating a correction factor of 0.999562 with a standard uncertainty (u) = 0.000183 were confirmed through comparison with the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at 532.12 nm using a silicon photodiode light trapping transfer standard. Further comparison with NACR5, an established LASP optical power standard, showed agreement within stated uncertainties demonstrating the effectiveness of the heat transport modelling approach for addressing electro-optical non-equivalence in planar thermal detectors.