Malcolm White

Malcolm White

Auto-generated profile, based on publicly available information

Malcolm White

Department of Physics, University of Colorado, Boulder, CO 80309, United States of America

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2018 in Metrologia
Verified
Journal Article
Open access
PDF file
MWM G White
M G White
ZRZ E Ruiz
Z E Ruiz
CYC S Yung
C S Yung
IVI Vayshenker
I Vayshenker
NTN A Tomlin
N A Tomlin
JLJ H Lehman
J H Lehman

10 August 2018 in Metrologia
Verified
Journal Article
Closed access
PDF file
MWMalcolm White
Malcolm White
GPGeiland Porrovecchio
Geiland Porrovecchio
DLDavid Livigni
David Livigni
RLRodney Leonhardt
Rodney Leonhardt
MSMarek Smid
Marek Smid
We report the characterisation and calibration of a new laser pulse energy measurement device, developed for pico-joule pulse energy measurement at repetition rates up to 1 kHz. The device comprises a charge integration amplifier operating in conjunction with an input charge source; a light trapping photo-detector, which converts an incident laser pulse to a charge pulse. The novel amplifier individually integrates each charge pulse from the source and outputs a corresponding 20-bit resolution digital signal. This signal is converted to pulse energy through post processing, knowing the absolute responsivity of the photodiode detector and the calibration factors of the charge amplifier. A differential evolution algorithm is used to determine optimised values for the feedback capacitors of the amplifier, the amplifier gain and offset. The values measured by the new laser pulse energy meter were compared with those obtained from measurements traceable to both the high and low-level laser pulse energy scales maintained by NIST, Boulder. These were consistent within the combined expanded measurement uncertainty. This new device offers lower uncertainty and portability, suitable for field use.

16 August 2022 in Metrologia
Verified
Journal Article
Open access
PDF file
MWMalcolm White
Malcolm White
KHKarl Heuerman
Karl Heuerman
PSPing-Shine Shaw
Ping-Shine Shaw
MSMichelle Stephens
Michelle Stephens
NTN A Tomlin
N A Tomlin
DHDave Harber
Dave Harber
We present the results of a recent, extensive measurement campaign validating the traceability of the solar irradiance record and Earth radiation budget data. The campaign also established future traceability, thus ensuring confidence in the continuing climate-data record. The total solar irradiance radiometer facility (TRF) at the Laboratory for Atmospheric and Space Physics (LASP) Boulder, uses a liquid helium cooled cryogenic radiometer as the reference standard for the validation of spaceflight total solar irradiance (TSI) instrumentation. In 2008 the radiometer was directly compared to the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at a wavelength of 532.12 nm. At TSI power levels, a correction factor of 1.000 306 with an associated standard uncertainty (u) of 0.000 098, was reported for the TRF radiometer scale when using external voltage measurement electronics, and not correcting for cavity heating non-equivalence or cavity absorptance. The TRF radiometer has recently been revalidated at LASP using a POWR calibrated silicon photodiode trap transfer standard named TT4. We report a correction factor of 0.999 787, u = 0.000 285 to align the TRF radiometer scale with the current NIST POWR scale. A new room temperature reference standard radiometer was established. It measured 133 parts per million (ppm) higher than POWR using the same silicon transfer standard as above, and in a separate direct measurement, 168 ppm lower than the TRF radiometer shuttered at 400 s full shutter cycle. The difference agrees within stated uncertainties. A correction of 0.999 867, u = 0.000 247 will align the new radiometer scale with the NIST radiant power scale of POWR.

17 June 2022 in Metrologia
Verified
Journal Article
Closed access
SWS I Woods
S I Woods
JNJ E Neira
J E Neira
JPJ E Proctor
J E Proctor
JRJ P Rice
J P Rice
NTN A Tomlin
N A Tomlin
JLJ H Lehman
J H Lehman
We have developed generalized methods for electrical substitution optical measurements, as well as cryogenic detectors which can be used to implement them. The new methods detailed here enable measurement of arbitrary periodic waveforms by an electrical substitution radiometer (ESR), which means that spectral and dynamic optical power can be absolutely calibrated directly by a primary standard detector. Cryogenic ESRs are not often used directly by researchers for optical calibrations due to their slow response times and cumbersome operation. We describe two types of ESRs with fast response times, including newly developed cryogenic bolometers with carbon nanotube absorbers, which are manufacturable by standard microfabrication techniques. These detectors have response times near 10 ms, spectral coverage from the ultraviolet to far-infrared, and are ideal for use with generalized electrical substitution. In our first tests of the generalized electrical substitution method with FTS, we have achieved uncertainty in detector response of 0.13% (k = 1) and total measurement uncertainty of 1.1% (k = 1) in the mid-infrared for spectral detector responsivity calibrations. The generalized method and fast detectors greatly expand the range of optical power calibrations which can be made using a wideband primary standard detector, which can shorten calibration chains and improve uncertainties.

3 December 2024 in Metrologia
Verified
Journal Article
Open access
JGJ Gieseler
J Gieseler
MWM G White
M G White
DHD Harber
D Harber
RHR Haun
R Haun
NTN A Tomlin
N A Tomlin
JLJ H Lehman
J H Lehman
We present the results of a finite element analysis of the electro-optical non-equivalence of planar electrical substitution radiometers with vertically aligned carbon nanotube absorbers, operating at either room or cryogenic temperature. These detectors are the basis of the new room temperature standards of the Laboratory for Atmospheric and Space Physics’ (LASP) Total solar irradiance Radiometer Facility and the Spectral solar irradiance Radiometer Facility, and the NIST Boulder open beam cryogenic radiometer facility. We show that the detector of our cryogenic electrical substitution radiometer has no significant electro-optical non-equivalence. Further, we also show that with careful detector design, the non-equivalence can be minimized at room temperature. It was found that in general the non-equivalence cannot be deduced from the temperature mismatch between the electrical and the optical states without considering the conductance mismatch and optical power input. The results are regarded as being precise rather than absolute to account for potentially unknown modeling errors. The numerical accuracy is typically less than 5 ppm.

8 April 2025 in Engineering Research Express
Verified
Journal Article
Open access
MSMatthew T Spidell
Matthew T Spidell
GPGaylon W Partain
Gaylon W Partain
AJAlan G Jaffe
Alan G Jaffe
MWMalcom G White
Malcom G White
JLJohn H Lehman
John H Lehman
DC voltage references are typically based on calibrated Zener Diodes which are subject to drift and therefore require periodic recalibration against a Primary Standard. Since it is preferable to maintain constant power to such references, the shipping and handling logistics involved in such a recalibration can present an unacceptable burden. Validation is therefore preferred, and typically accomplished by comparison against other local Zener Diodes. However, these Zener Diodes are all subject to correlated aging mechanisms. Voltage to frequency conversion represents an alternative mechanism for validation and accordingly, is not subject to aging highly correlated with the system being validated. Voltage to frequency conversion using a low space, weight, and power Voltage Controlled Oscillator offers a mechanism for identifying voltage reference drift by comparing the voltage-controlled frequency to primary frequency, typically available through GPS. This technique can validate voltage references when comparison against a primary voltage standard is impractical due to system deployment, away from a robust logistics chain. Voltage to frequency conversion may be accomplished by a Voltage Controlled Ovenized Crystal Oscillator. Using commercial-off-the-shelf hardware we constructed a test to evaluate the stability of such an oscillator for 258 days of continuous run-time, without age acceleration measures. Long-term drift was consistent with a t aging model. Sequestering 2/3 of the data to construct an aging model, then comparing sequestered data, yielded a model-to-data difference of 35 ppm (35 μV/V) which may prove acceptable in supporting instruments in the 6.5-digit voltmeter class.