Yu-Chong Tai

Yu-Chong Tai

Auto-generated profile, based on publicly available information

Yu-Chong Tai

California Institute of Technology, Pasadena, USA

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1999
Verified
Conference Paper
Open access
CGC. Grosjean
C. Grosjean
XYXing Yang
Xing Yang
YTYu-Chong Tai
Yu-Chong Tai
Previously, we reported a thermopneumatic silicone rubber membrane valve [1997]. This valve combined thermopneumatic actuation with a low modulus silicone rubber membrane. However, the leakage of the working fluid through the membrane rendered the valve unusable in a day or two. Here, we present extensive optimization and characterization of a redesigned valve structure. This new design has a suspended membrane heater optimized for low power consumption, a composite silicone rubber on Parylene membrane that exhibits low permeability and modulus, and a novel valve seat designed to improve sealing in the presence of particles. The valve has been extensively characterized with respect to power consumption vs. flow rate and transient response. Very low power consumption has been demonstrated. For example, less than 40 mW is required to switch a one slpm nitrogen flow at 33 psi. Water requires close to 100 mW due to the cooling effect of the liquid. The previously reported valve required more than 280 mW to switch a similar air flow.

1 January 2018
Verified
Conference Paper
Closed access
ASAubrey Shapero
Aubrey Shapero
YTYu-Chong Tai
Yu-Chong Tai
This paper demonstrates a parylene-oil-encapsulated packaging technology that applies to commercial pressure sensors to enable intraocular pressure sensing with minimal drift. Commercial digital-output barometers are chosen to be packaged first with 100,000 cSt silicone oil and then sub-micron thick parylene within the volume of the original housing. It is newly found that parylene type and oil viscosity can decide the sign and magnitude of the intrinsic stress in parylene. Additionally, the effect of deposited thickness and temperature on film stress is studied through induced pressure offset. When properly designed, parylene-oil-encapsulated pressure sensors maintain <;0.3% sensitivity drift and <;1 to 2 mmHg offset drift for over 50 to 106+ days in 77 °C saline, equivalent to 25 to 53+ months at 37 °C [1]. This new compact packaging method is promising for converting air-operated commercial sensors to be “implantable” with nearly original sensitivity and minimal offset and drift.

1 February 2013
Verified
Conference Paper
Closed access
MMManuel Monge
Manuel Monge
MRMayank Raj
Mayank Raj
MHMeisam Honarvar-Nazari
Meisam Honarvar-Nazari
HCHan-Chieh Chang
Han-Chieh Chang
YZYu Zhao
Yu Zhao
AEAzita Emami-Neyestanak
Azita Emami-Neyestanak
Since their conception and success in human trials, the flexibility and spatial resolution of retinal prostheses have been of major interest. Clinical studies have revealed that hundreds of channels are needed to restore functional visual perception, and more sophisticated waveforms present advantages over biphasic pulses. Initial designs targeted stimulation current levels up to 1mA to ensure functionality. For such designs, an output compliance of >10V was required, and HV technologies were used at the expense of area and power consumption. Human clinical trials have recently shown that implanted electrodes present a stimulus threshold as low as 50μA. In addition, advances in implant technology promise close placement of electrode array and retinal tissue, which can further decrease the required current. Thus, highly scaled LV technologies can provide alternative means to reduce area and power, and to support hundreds of flexible independent channels for fully intraocular implants. In this paper, a self-calibrating 512-channel epiretinal prosthesis in 65nm CMOS is presented. It features dual-band telemetry for power and data, clock recovery, a 2-step calibration technique to match biphasic stimulation currents, and an independent arbitrary output waveform per channel. The implant integrates coils (power and data), IC, external capacitors and electrode array using a biocompatible parylene substrate, providing a fully intraocular solution.

1 January 2012
Verified
Conference Paper
Closed access
JCJay Han-Chieh Chang
Jay Han-Chieh Chang
DKDongyang Kang
Dongyang Kang
YTYu-Chong Tai
Yu-Chong Tai
This paper reports a new chip packaging technique for the assembly of retinal prosthesis device. Here, a photoresist is used as glue to attach a chip to the targeted parylene-C substrate so that 94% of the chip area is used as attachment to prevent delamination. As a validation, chips with 268 connections were used to assess the connection yield. The results show that this new technique, combined with an additional parylene-C coating, provide a high connection yield (>;90%) and is a promising method for high-lead-count implant devices.

10 October 2018 in Micro and Nano Systems Letters
Verified
Journal Article
Open access
PDF file
YLYaoping Liu
Yaoping Liu
DKDongyang Kang
Dongyang Kang
WDWangzhi Dai
Wangzhi Dai
HLHaida Li
Haida Li
Wei WangWei Wang
Wei Wang
YTYu-Chong Tai
Yu-Chong Tai
Thanks to the excellent barrier property and fabrication accessibility, Parylene has been actively used in the microelectromechanical system. An ultra-thin Parylene film with thickness smaller than 100 nm is usually required to precisely tune the surface property of substrate or protect the functional unit. The commercially available regular Parylene deposition is a dimer mass determined chemical vapor deposition process with a high output (i.e. a low deposition precision in term of thickness control), around 1.6 μm/g (the ratio of film thickness to the loaded dimer mass) for the machine in the author’s lab. Therefore, it is hard to controllably and reliably prepare a Parylene film with thickness smaller than 100 nm, which requires a dimer mass less than 62.5 mg. This paper reported a method to prepare ultra-thin Parylene films with the nominal thickness down to 1 nm. A home-made deposition chamber was put inside and connected with the regular machine chamber through a microfabricated orifice with feature size smaller than 1 mm. According to the free molecular flow theory, the pressure inside the deposition chamber can be predictably and controllably reduced, thereby an ultra-low output of Parylene deposition, as low as 0.08 nm/g, was successfully obtained. The deposition precision was increased by 4 orders of magnitude compared to that of a direct Parylene deposition. This highly controllable and reliable ultra-thin Parylene deposition technique will find promising applications in flexible electronics and biomedical microdevices.

1 January 2016
Verified
Conference Paper
Closed access
WWWei Wang
Wei Wang
DKDongyang Kang
Dongyang Kang
WDWangzhi Dai
Wangzhi Dai
YTYu-Chong Tai
Yu-Chong Tai
This paper reports a novel and reliable process to prepare ultra-thin parylene film based on a principle combining both molecular effusion and diffusion. For the first time, a technique for the deposition of parylene film thinner than 20 nm in a highly controllable and repeatable way is developed. Parylene films with various thicknesses could also be prepared in a single deposition run by using this method. This technique holds promising potentials in extensive applications, such as protection/dielectric layer for needle electrodes and flexible electronics, semi-permeable membrane, and other polymer engineering.