14 September 2023 in IEEE Access
The growing integration of distributed energy resources into distribution systems poses challenges to voltage regulation. Dynamic VAR Compensators (DVCs) are a new generation of power electronics-based Volt/VAR compensation devices designed to address voltage issues in distribution systems with a high penetration of renewable generation resources. Currently, the IEEE Std. 1547 based Volt/VAR Curve (VV-C) is widely used as the local control scheme for controlling a DVC. However, the effectiveness of this scheme is not well documented, and there is limited literature on alternative control and placement schemes that can maximize the effective use of a DVC. In this paper, we propose an optimal dispatch and control mechanism to enhance the conventional Volt/VAR Curve (VV-C) based localized DVC control. First, we establish a multi-objective optimization framework to identify the optimal dispatch strategy and suitable placement for the DVC. Next, we introduce two supervisory control strategies to determine the appropriate instances for adjusting the VV-C when the operating condition changes. The outlined scheme comprises two primary stages: time segmentation and VV-C fitting.Within this framework, each time segment aims to produce optimized Q-V trajectories. The proposed method is tested on a modified IEEE 123-bus test system using OpenDSS for a wide range of operating scenarios, including sunny and cloudy days. Simulation results demonstrate that the proposed scheme effectively reduces voltage variations compared to the standard VV-C specified in IEEE Std. 1547.
10 March 2025 in IEEE Transactions on Industry Applications
With the increased integration of Distributed Energy Resources (DER), the sudden tripping of DER during a fault adversely affects the grid stability and operation. Hence, the DER is expected to exhibit Low Voltage Ride-Through (LVRT) capabilities with reactive power support during a fault, as per IEEE 1547. Determining the amount of reactive power during unsymmetrical faults in the distribution system is challenging as it requires unbalanced reactive power support depending on the type of fault. Proper reactive power support can also help minimize the voltage rise in the healthy phases. This paper proposes a novel Per-Phase Reactive Power Control (PRPC) strategy that enables DER to inject reactive power in faulted phases and absorb reactive power in healthy phases during an unbalanced fault. This strategy helps boost voltages on faulted phases while reducing the voltage rise on the healthy phases. Test results on a sample distribution system are given to illustrate the advantages of this proposed scheme. In addition to validating the analytical framework with simulations, the effectiveness of the proposed PRPC strategy is also further validated through a real-time simulation performed on NovaCor Real-Time Digital Simulator (RTDS).
1 June 2007 in 2007 IEEE Power Engineering Society General Meeting
Summary form only given. Recently, renewable wind energy is enjoying a rapid growth globally to become an important green electricity source to replace polluting and exhausting fossil fuel. However, with wind being an uncontrollable resource and the nature of distributed wind induction generators, integrating a large-scale wind-farm into a power system poses challenges, particularly in a weak power system. In the paper, the impact of STATCOM to facilitate the integration of a large wind farm into a weak power system is studied. First, an actual weak power system with two nearby large wind farms is introduced. Based on the field SCADA data analysis, the power quality issues are highlighted and a centralized STATCOM is proposed to solve them, particularly the short-term (seconds to minutes) voltage fluctuations. Second, a model of the system, wind farm and STATCOM for steady-state and dynamic impact study is presented, and the model is validated by comparing with the actual field data. Using simulated PV and QV curves, voltage control and stability issues are analyzed, and the size and location of STATCOM are assessed. Finally, a STATCOM control strategy for voltage fluctuation suppression is presented and dynamic simulations verify the performance of proposed STATCOM and its control strategy.
29 September 2023 in IEEE Transactions on Industry Applications
For real-time monitoring of distribution systems, distribution system state estimation (DSSE) methods have been developed. For accurate DSSE results, an accurate system model is needed. However, topology of a distribution network changes due to various reasons and some changes may not be monitored or known to the control center. This leads to an incorrect model used for the DSSE and thus causes incorrect estimation results. The main contributions of this paper includes development of a topology monitoring scheme using bad data detection (BDD) methods in the presence of the most common topology errors in practice, including capacitor bank failure and load balancing. Additionally, common measurement schemes are investigated to determine how a measurement scheme can be used in order to improve topology error detection. Test results using a sample IEEE distribution feeder have been provided to illustrate the the effectiveness of the proposed scheme.