14 October 2021 in Mathematical Problems in Engineering
This paper shows an analytic hierarchy process (AHP) algorithm-based approach for load shedding based on the coordination of the load importance factor (LIF), the reciprocal phase angle sensitivity (RPAS), and the voltage electrical distance (VED) to rank the load buses. This problem is important from a power system point of view, and the AHP method is able to support the decision-making process in a simple and intuitive way in a three-criterion environment. This satisfies the multicriteria decision-making to meet economic-technical aspects. The ranking and distributed shedding power at each demand load bus are based on this combined weight. The smaller overall weights of the load buses show the lesser importance of the load bus, the smaller reciprocal phase angle sensitivity, and the closer voltage electrical distance. Therefore, these load buses cut a larger amount of capacity, and vice versa. By considering the generator control, the load shedding consists of the primary and secondary control features of the generators to minimize the load shedding capacity and restore the system frequency value back to the allowable range. The efficiency of the suggested load-shedding scheme was verified via the comparison with the under-frequency load shedding (UFLS). The latter result is that the load shedding power of the suggested approach is 22.64% lower than the UFLS method. The case studies are experienced on the IEEE 9-generator; the 37-bus system has proven its effectiveness.
13 July 2020 in IEEE Access
This paper proposes the models to solve the optimal generator dispatching problem in an islanded Micro grid with different uncertainties in the constraint and in the objective coefficient. The optimal problem with interval in the power balance constraint is considered as a linear parametric optimization problem, focusing on optimal solutions based on the lower and upper ends of this interval. When the coefficients of cost per power unit caused by load shedding are imprecise and expressed as intervals, the proposed model will be based on the two ends of interval and the problem is converted to a two-objective problem. With uncertainties in both constraint and objective coefficient, the problem will be treated as a four-objective one, considering the lower and upper ends of all intervals. All models are expressed in the linear forms and the linearization is carried out by Max-Affine method. To solve this multi-objective problem, the Bellman-Zadeh approach and Particle Swarm Optimization (PSO) algorithm are applied. The rationality of the proposed models is confirmed in the case study with one low voltage Micro Grid.
4 March 2019 in IETE Journal of Research
A large oscillation of power system caused by faults must be quickly treated so that the opportunity driving power system into re-stability state can be easier. Necessity is to select a compact data-set that is the representative of all data-sets with the aim of reducing computing costs, reducing computer memory, and improving classification accuracy. The K-means (KM) algorithm is the most commonly used clustering algorithm because it can be easily implemented and is the most effective one in terms of the execution time on large data size. The key problem of KM is that it is sensitive to initial center and may converge to a local optimization. In this paper, we proposed the use of Hybrid K-means (HKM) data clustering algorithm that can avoid being trapped in a local optimal solution. The HKM was applied with the aim of reducing data space. We also proposed a process data clustering applied to classify the problem of dynamic stability in power system. The K-Nearest Neighbor (K-NN) was chosen as the classifier. The K-NN participated in the evaluating classification accuracy stage. The study was done on IEEE 39-bus. The results showed that the proposed algorithm achieved effective data size reduction and high accuracy classification.