7 February 2025 in Journal of Arrhythmia
In the era of cryoablation and pulsed‐field ablation, where large sheaths are commonly used, preventing air embolism is crucial. The lid from SL sheath packaging can be repurposed as a water‐seal device for catheter insertion, thereby eliminating the need for additional equipment.
1 December 2025 in EP Europace
Aims: Catheter ablation for premature ventricular contractions (PVCs) triggering ventricular fibrillation (VF) after acute myocardial infarction (AMI) has proven effective, with Purkinje potentials often serving as the target. However, the electrophysiological features of Purkinje potentials and their relationship with the conduction system in VF-triggering PVCs remain unclear. Methods: This multicentre retrospective study analysed patients who underwent catheter ablation for VF-triggering PVCs during the acute or subacute phase of AMI. Characteristics of Purkinje potentials, including retrograde conduction from the Purkinje network and subsequent anterograde conduction to the right bundle branch (RB), were evaluated for PVC morphology. Results: Fifty-three patients (mean age 66±11 years; 13% female) with 67 VF-triggering PVCs were analysed. The mean PVC width was 157 ± 42 ms, with 87% showing RB branch block morphology. Purkinje potentials preceded 72% of PVCs (mean interval 68 ± 42 ms). PVCs with preceding Purkinje potentials had narrower QRS duration (145 ± 26 ms vs. 198 ± 57 ms, P < 0.0001). The coupling interval from the preceding sinus beat was inversely correlated with the interval from Purkinje potential to PVC onset (P < 0.0001). Retrograde Purkinje conduction with subsequent anterograde RB conduction was identified in 9%. In these cases, the coupling interval from the preceding sinus beat was longer (391 ± 12 ms vs. 467 ± 34 ms, P = 0.041). Conclusion: Purkinje potentials show distinct properties that influence both QRS duration and PVC timing. The presence of preceding Purkinje potentials together with QRS duration may help guide ablation strategies. In rare cases, Purkinje activity conducts retrogradely from the left bundle and anterogradely through the RB, modifying PVC morphology.
21 March 2025 in Journal of Arrhythmia
Background: In pulmonary vein isolation (PVI) for atrial fibrillation (AF), intraoperative defibrillation is often required. Intracardiac defibrillation catheters (ICDCs) are most effective when positioned to enclose the heart between the coronary sinus (CS) and right atrium (RA) (CS/RA configuration). However, achieving this positioning via the inferior vena cava (IVC) can be challenging, and alternative configurations remain underexplored. Methods: This study included patients with paroxysmal or persistent AF who underwent cryoballoon ablation followed by intracardiac cardioversion using an ICDC via the IVC. The catheter was initially positioned with distal electrodes in the CS and proximal electrodes in the IVC (CS‐only configuration). If cardioversion failed, the catheter was repositioned to place distal electrodes in the superior vena cava (SVC configuration). A maximum of 30 J of energy was used for all cardioversion attempts. Results: A total of 81 patients were included. Cardioversion in the CS‐only configuration restored sinus rhythm in 11% (9/81) of patients. Repositioning to the SVC configuration achieved successful cardioversion in 93.1% (67/72) of the remaining cases without complications. Patients requiring the SVC configuration had a significantly higher prevalence of persistent AF (33.3% vs. 80.6%; p = 0.045). No adverse events were observed following cardioversion in the SVC configuration. Conclusions: While the CS‐only configuration offers ease of placement, its efficacy is limited. Repositioning to the SVC configuration significantly enhances cardioversion success and represents a safer, more effective alternative for ICDC use during AF ablation.
19 July 2026 in Journal of Cardiovascular Electrophysiology
7 October 2026 in HeartRhythm Case Reports