We present a device based on low-cost electrochemical and optical sensors, designed to be attached to bicycle handlebars, with the aim of monitoring the air quality in urban environments. The system has three electrochemical sensors for measuring NO2 and O3 and an optical particle-matter (PM) sensor for PM2.5 and PM10 concentrations. The electronic instrumentation was home-developed for this application. To ensure a constant air flow, the input fan of the particle sensor is used as an air supply pump to the rest of the sensors. Eight identical devices were built; two were collocated in parallel with a reference urban-air-quality-monitoring station and calibrated using a neural network (R2 > 0.83). Several bicycle routes were carried out throughout the city of Badajoz (Spain) to allow the device to be tested in real field conditions. An air-quality index was calculated to facilitate the user’s understanding. The results show that this index provides data on the spatiotemporal variability of pollutants between the central and peripheral areas, including changes between weekdays and weekends and between different times of the day, thus providing valuable information for citizens through a dedicated cloud-based data platform.
This work describes the technical features and the performance of two different types of metal-oxide semiconductor sensors, based on ZnO:Ga thin films and SnO2-G nanofibrous layers, for tropospheric ozone monitoring in ambient air. These nanostructures were tested and compared with commercial metal-oxide semiconductor sensors under controlled laboratory conditions and in a field campaign during summer 2021 in Monfragüe National Park (western Spain). The paper also details the design of the electronic device developed for this purpose. A machine learning algorithm based on Support Vector Regression (SVR) allowed the conversion of the resistive values into ozone concentration, which was evaluated afterward. The results showed that the manufactured sensors performed similarly to the commercial sensors in terms of R2 (0.94 and 0.95) and RMSE (5.21 and 4.83 μg∙m−3). Moreover, a novel uncertainty calculation based on European guides for air quality sensor testing was conducted, in which the manufactured sensors outperformed the commercial ones.