Jun Wu

Jun Wu

Auto-generated profile, based on publicly available information

Jun Wu

School of Electrical Engineering, Nantong University, No. 9, Seyuan Road, Nantong 226019, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
JWJun Wu
Jun Wu
MLMingzhen Li
Mingzhen Li
CGChao Gao
Chao Gao
ZLZehui Liu
Zehui Liu
BZBo Zhang
Bo Zhang
XZXinsong Zhang
Xinsong Zhang
In order to achieve more effective online monitoring of distribution cables, a deployment scheme of the distribution cable condition monitoring devices based on a wireless sensor network (WSN) has been proposed. The proposed deployment scheme can improve the coverage rate and extend the lifetime of the sensor network. Moreover, the clustering method, node density, and node deployment method of the wireless sensor routing algorithm are improved, and based on isosceles triangle non-uniform deployment, a routing optimization algorithm has been proposed to achieve the balance of the energy consumption of each node in the network. Firstly, according to the energy consumption model of the network, the energy consumption of each cluster is calculated, and then by taking the minimum energy consumption of data transmission between clusters as the constraint condition, the optimal clustering distance of the network is solved. Then, according to the scale of network nodes, the density of routing nodes in each cluster is calculated, and the routing nodes in the cluster are deployed by an isosceles triangle. Finally, according to the cluster head election formula, the routing cluster head nodes in each cluster are selected, and the network data information is transmitted to the base station in a multi-hop manner through the routing cluster head nodes. The simulation results indicated that, compared with the traditional routing optimization algorithms, the proposed algorithm could keep the routing coverage at more than 200% all the time, and can effectively balance the energy consumption of nodes, improve the energy utilization efficiency of the routing nodes, and at least extend the lifetime of the network by two times. Moreover, the longer the cables, the more cost savings and the better the life cycle optimization effect of the proposed scheme. In addition, the proposed scheme can greatly reduce the economic cost of network investment, compared with using the demodulator to obtain monitoring data.

11 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
BYBin Yang
Bin Yang
ZXZhanran Xia
Zhanran Xia
XGXinyun Gao
Xinyun Gao
JTJing Tu
Jing Tu
HZHao Zhou
Hao Zhou
MLMingzhen Li
Mingzhen Li
In HV cable fault location technology, line parameter uncertainty has an impact on the location criterion and affects the fault location result. Therefore, it is of great significance to study the uncertainty quantification of line parameters. In this paper, an impedance-based fault location criterion was used for an uncertainty study. Three kinds of uncertainty factors, namely the sheath resistivity per unit length, the equivalent grounding resistance on both sides, and the length of the cable section, were taken as random input variables without interaction. They were subject to random uniform distribution within a 50% amplitude variation. The relevant statistical information, such as the mean value, standard deviation and probability distribution, of the normal operation and fault state were calculated using the Monte Carlo simulation (MCS) method, the polynomial chaos expansion (PCE) method, and the univariate dimension reduction method (UDRM), respectively. Thus, the influence of uncertain factors on fault location was analyzed, and the calculation results of the three uncertainty quantification methods compared. The results indicate that: (1) UQ methods are effective for simulation analysis of fault locations, and UDRM has certain application prospects for HV fault location in practice; (2) the quantification results of the MCS, PCE, and UDRM were very close, while the mean convergence rate was significantly higher for the UDRM; (3) compared with the MCS, PCE, and UDRM, the PCE and UDRM had higher accuracy, and MCS and UDRM required less running time.