Dirk Bosche

Dirk Bosche

Auto-generated profile, based on publicly available information

Dirk Bosche

Institute for High Voltage Technology and Power Systems, Technische Universitt Braunschweig, Braunschweig, Germany

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2016 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Closed access
DBDirk Bösche
Dirk Bösche
EWErnst-Dieter Wilkening
Ernst-Dieter Wilkening
HKHendrik Köpf
Hendrik Köpf
MKMichael Kurrat
Michael Kurrat
Recently, a growing number of dc systems exist based on the development of electrical energy consumption. For low-voltage dc grids, switching devices are needed that have to meet technically sophisticated requirements. These devices have to handle fault currents of several hundred amperes and system voltages up to 1000 V. A typical dc circuit breaker has to provide low on-state losses, light weight, and small volume. On the way toward fulfilling these requirements, hybrid circuit breakers can represent the optimal solution. A hybrid dc circuit breaker combines the advantages of mechanical contacts and semiconductors. In this paper, such a device has been designed and constructed using a commercial switch and electronic components in the laboratory. The breaking performance of this experimental prototype has been investigated, and thus the interruption of the nominal and failure currents in the case of different time constants can be identified. The investigated hybrid switching device has been optimized in order to maximize the switching capacity and the protection of the semiconductors.

13 December 2021 in IEEE Access
Verified
Journal Article
Open access
DBDirk Bosche
Dirk Bosche
PVPatrick Vieth
Patrick Vieth
FAFrederik Anspach
Frederik Anspach
EPEnno Peters
Enno Peters
EWErnst-Dieter Wilkening
Ernst-Dieter Wilkening
MKMichael Kurrat
Michael Kurrat
The number of devices either providing or demanding direct current is growing more and more. This led to the renascence of DC grids and revealed a need for research. One critical component is the DC circuit breaker. It has to handle nominal and fault currents to keep the grid stable and operable. Interrupting currents in DC grids can be challenging because of the absence of a natural current zero crossing. Therefore, complex arcing chambers are needed. Especially at low currents, the self-induced force may not be sufficient to force the arc into the arcing chamber. Hybrid circuit breakers (HCB) are one possible solution to meet theses sophisticated requirements. There are several different topologies. All have in common that mechanical switches and semiconductors are combined to create a switch with the advantages of both technologies. One simple solution consists of two mechanical switches and one bypassing semiconductor circuit. The arc is used to achieve commutation from the mechanical to the semiconductor branch. While it carries the current, the mechanical switch regains its dielectric strength. Since this recovery time is short, the semiconductor can be overloaded within the limits of its thermal capacity. Defining the recovery time can be challenging. In addition, the effect of contact distance, arcing time and current value are unknown. To research the recovery behavior a model-switching chamber with an adjustable contact gap is developed. This device under test (DUT) was implemented into a test circuit that reproduces part of the hybrid switching process. When the arc between the contacts of the DUT reaches its steady state, a parallel commutating path is activated. The residual conductance of the decaying arc was measured. The development and several iteration steps of the test circuit and DUT are laid out. Finally, some test runs and initial measurements are presented.

30 January 2025 in IEEE Access
Verified
Journal Article
Open access
HSHendrik Schefer
Hendrik Schefer
MBMaximilian Bien
Maximilian Bien
JGJan Gülink
Jan Gülink
DBDirk Bösche
Dirk Bösche
JGJan Goeing
Jan Goeing
JFJens Friedrichs
Jens Friedrichs
Power electronics design offers many options to achieve the high required power density to replace conventional aircraft components. Two promising approaches are to increase the power supply voltage and use wide-bandgap semiconductors. However, there are many concerns about the high-voltage approach, particularly regarding reliability and fault tolerance. Improving the power density with high voltages requires wide-bandgap semiconductors, which further stresses the insulation. Furthermore, the environmental stressors are partly unknown because of the need for a design basis. Existing industrial standards and other investigations address this issue only partly. This publication uses a mission profile and a design of experiment-based reliability assessment approach for creepage distances on printed circuit boards to overcome the concerns against the promising high voltage approach in aviation applications from the perspective of power electronics. The investigation delivers experimentally and mathematically described wet and dry surface flashover results. Furthermore, the influence of degradation of creepage distances caused by wide-bandgap semiconductors is experimentally investigated. The publication also gives design recommendations for gaining reliability and fault tolerance of creepage distances on printed circuit boards for operating power-dense power electronics in integrated electrified propulsion systems.

24 October 2021
Verified
Conference Paper
Closed access
FAFrederik Anspach
Frederik Anspach
PVPatrick Vieth
Patrick Vieth
DBDirk Bosche
Dirk Bosche
LCLars Claassen
Lars Claassen
EWErnst-Dieter Wilkening
Ernst-Dieter Wilkening
MKMichael Kurrat
Michael Kurrat
The application of hybrid circuit breakers (HCB) is possible in all voltage levels of DC-grids. For high voltage direct current transmission applications, HCBs are often equipped with commutation power electronics (PE). In low voltage grids, the use of commutation PEs is mostly avoided. Thus, a longer arcing process for commutation results from the mechanical circuit breaker to the PEs. As a result, a higher energy entry of the gas within the mechanical circuit breaker occurs. However, the components and the expenditure for the control unit is significantly reduced which is highly beneficial. This contribution presents a new method to optimize the deionization time of HCBs without commutation PEs for LVDC and MVDC-grids. They are applied to different test grids to show the opportunities of this technology. To ensure a relative fast switching time, a method to determine the minimum deionization time (DI) is developed and presented in order to avoid arc reignitions. This contribution shows the functionality of this method and discusses the efficiency varying different parameters.