Mesut Erbas

Mesut Erbas

Auto-generated profile, based on publicly available information

Mesut Erbas

Department of Anesthesiology and Reanimation, Medical Faculty, Çanakkale Onsekiz Mart University, Çanakkale, Turkey

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
PDF file
MUMetehan Uzun
Metehan Uzun
HKHasan Ali Kiraz
Hasan Ali Kiraz
MOMehmet Akif Ovali
Mehmet Akif Ovali
HSHasan Sahin
Hasan Sahin
MEMesut Erbas
Mesut Erbas
HTHuseyin Toman
Huseyin Toman
PURPOSE:To evaluate the applicability and airway management capacity of v-gel(r) and Cobra PLA in rabbit anaesthesia during assisted (AV) or controlled ventilation (CV).METHODS:This study was carried out in 44 adult New Zealand white rabbit. Baseline arterial pH, PaCO2 and PaO2 values were recorded. Anaesthesia was induced with 5 mg/kg xylasine and 35 mg/kg ketamine HCI combination. AV rabbits were assigned as; control (CG-AV; n=5), LMA (LMA-AV; n=5), cobra PLA (PLA-AV; n=5) and v-gel (v-gelAV; n=5). Rabbits have CV were also assigned as; ET (ET-CV; n=6), LMA (LMA-CV; n=6), cobraPLA (PLA-CV; n=6) and v-gel (v-gelCV; n=6). All measurements were repeated 1st, 5th, 15th and 30th mins during anaesthesia.RESULTS: The less insertion time, number of attempt and complications are recorded in v-gel applied rabbits compared to other apparatus. For arterial pH values significant differences are recorded in especially at 15th and 30th min between groups of CV (p<0.005 or p<0.001). All groups had similar results with each other during anaesthesia for PaCO2 except for LMA-CV group.CONCLUSION:The v-gel may be used as airway device in rabbit anaesthesia undergoing AV or CV and also can be a suitable alternative to endotracheal tubes and laryngeal mask airway.

1 September 2015 in Revista Brasileira de Anestesiologia
Verified
Journal Article
Open access
MEMesut Erbas
Mesut Erbas
TSTuncer Simsek
Tuncer Simsek
HKHasan Ali Kiraz
Hasan Ali Kiraz
HSHasan Sahin
Hasan Sahin
HTHuseyin Toman
Huseyin Toman
Tenoxicam is widely used in osteoarthritis treatment and we aimed to compare the effectivity of oral and intra-articular administration of tenoxicam in osteoarthritis treatment. This study was performed between 2011 and 2012 by retrospectively analyzing and comparing the findings of 60 patients who were clinically and radiologically diagnosed with knee degenerative osteoarthritis in Bünyan state hospital pain policlinic. 60 patients included in the study were divided into two groups. The first group (tenoxicam IA, n=30) included patient findings of those subjected to intra-articular injection of 20mg tenoxicam to the knee once a week for three weeks and the second group (oral tenoxicam, n=30) included patients who were administered 20mg oral tenoxicam once a day for three weeks. All patients were clinically evaluated pre-treatment and in the 1st week, 1st month and 3rd month post-treatment according to specified criteria. 22 of 60 patients included in the study were male and 38 were female. In both groups significant improvements were detected in all of the observed parameters: visual analog scale, Western Ontario McMaster Osteoarthritis Index (pain, physical activity, knee stiffness) and Lequesne index scores and in the evaluations performed in 1st week, 1st month and 3rd month with respect to pre-treatment values. Besides, a better compliance to treatment and gastrointestinal system tolerability in tenoxicam IA group was also observed. Intra-articular tenoxicam administration could be thought as an alternative treatment method in patients with knee osteoarthritis who cannot use oral tenoxicam especially due to systemic gastrointestinal system side effects and those who have difficulties in adapting to treatment.

1 September 2015 in Brazilian Journal of Anesthesiology (English Edition)
Verified
Journal Article
Open access
MEMesut Erbas
Mesut Erbas
TSTuncer Simsek
Tuncer Simsek
HKHasan Ali Kiraz
Hasan Ali Kiraz
HSHasan Sahin
Hasan Sahin
HTHuseyin Toman
Huseyin Toman
Tenoxicam is widely used in osteoarthritis treatment and we aimed to compare the effectivity of oral and intra-articular administration of tenoxicam in osteoarthritis treatment. This study was performed between 2011 and 2012 by retrospectively analyzing and comparing the findings of 60 patients who were clinically and radiologically diagnosed with knee degenerative osteoarthritis in Bünyan state hospital pain policlinic. 60 patients included in the study were divided into two groups. The first group (tenoxicam IA, n=30) included patient findings of those subjected to intra-articular injection of 20mg tenoxicam to the knee once a week for three weeks and the second group (oral tenoxicam, n=30) included patients who were administered 20mg oral tenoxicam once a day for three weeks. All patients were clinically evaluated pre-treatment and in the 1st week, 1st month and 3rd month post-treatment according to specified criteria. Twenty two of 60 patients included in the study were male and 38 were female. In both groups significant improvements were detected in all of the observed parameters: visual analog scale, Western Ontario McMaster Osteoarthritis Index (pain, physical activity, knee stiffness) and Lequesne index scores and in the evaluations performed in 1st week, 1st month and 3rd month with respect to pre-treatment values. Besides, a better compliance to treatment and gastrointestinal system tolerability in tenoxicam IA group was also observed. Intra-articular tenoxicam administration could be thought as an alternative treatment method in patients with knee osteoarthritis who cannot use oral tenoxicam especially due to systemic gastrointestinal system side effects and those who have difficulties in adapting to treatment.

6 March 2014 in Diseases of the Esophagus
Verified
Journal Article
Closed access
PDF file
MEM. Erbaş
M. Erbaş
HKH. A. Kiraz
H. A. Kiraz
AKA. Küçük
A. Küçük
NTN. Topaloğlu
N. Topaloğlu
HEH. Erdem
H. Erdem
MOM. Turgut Alper Ozkan
M. Turgut Alper Ozkan

1 July 2016 in SpringerPlus
Verified
Journal Article
Open access
PDF file
TŞTuncer Şimşek
Tuncer Şimşek
UAUğur Altınışık
Uğur Altınışık
İEİsmail Erşan
İsmail Erşan
HŞHasan Şahin
Hasan Şahin
BABetül Altınışık
Betül Altınışık
ÇPÇiğdem Uysal Pala
Çiğdem Uysal Pala
Oleuropein is known to have anti-oxidant and anti-inflammatory effects. An important aim of anesthetic management in ocular surgery is to keep the intraocular pressure under control. Studies have researched a variety of prophylactic materials used to prevent increases in intraocular pressure. We aimed to research the effects of oleuropein on intraocular pressure (IOP) during general anaesthesia. Fourteen New Zealand rabbits were randomly divided into two groups of seven. The rabbits in Group O were given olive leaf extract (OLE) equivalent to a daily dose of 20 mg/kg oleuropein for 15 days. HPLC method used for oleuropein standardization. For anaesthesia induction 1 mg/kg rocuronium was given and after muscle relaxation all animals had a V-gel Rabbit inserted. Anesthetic maintenance was provided by 1 MAC isoflurane. Twenty minutes after rabbits were given 10 mg/kg ketamine, basal IOP values were measured. After the V-gel rabbit was inserted, in the 5th, 10th, 20th, 25th and 30th minutes measurements were repeated. IOP data variation of OLE group was compared with control group and the measured levels were lower in Group O during the anaesthesia. IOP was 33.8 ± 4 mmHg in Group C and 24.1 ± 8 mmHg in Group O in 25th minute and the difference between the two groups was statistically significant at this time. We observed that consumption of prophylactic OLE had a reducing effect on IOP in the period before waking in anaesthesia. We believe it is necessary to investigate the effects of OLE on IOP in broad participation patient groups.

6 August 2015 in Turkish Journal of Anesthesia and Reanimation
Verified
Journal Article
Closed access
MEMesut Erbas
Mesut Erbas
HKHasan Ali Kiraz
Hasan Ali Kiraz
TSTuncer Simsek
Tuncer Simsek
HSHasan Sahin
Hasan Sahin
HTHuseyin Toman
Huseyin Toman
VHVolkan Hanci
Volkan Hanci
Obstructive sleep apnea (OSA) is an important health problem that is increasing with the increase in the incidence of obesity. For patients with OSA, it is reported that preoperative OSA diagnosis is made in only 10%-20% of the patients. Therefore, it gains importance that these patients are diagnosed in the preoperative period. The aim of this study is to analyze with a survey the experiences of anaesthesia experts working in Turkey about the diagnosis of patients with OSA, anaesthetic methods and postoperative care. The study was completed with an online survey form distributed via email. Survey participants were sent an email, and those experts who wished to participate clicked on the link, answered the questions and returned the survey via email. A total of 134 anaesthesia experts participated in this study. While 97% of the participating anaesthetists considered diagnosis of patients with OSA to be important, only 53% trusted themselves to recognize this patient group. Of the total number of participants. 43% did not know the STOP-BANG test used in the preoperative period to diagnose patients with OSA. The percentage who thought that patients with OSA would increase the incidence of difficult intubation was 84%. In the intraoperative period, the percentage who chose inhalation anaesthetics was 35%, whereas the rate of those who chose total intravenous anesthesia (TIVA) was 48%. This study indicates that the medical knowledge of Turkish anaesthetists on the topic of OSA requires updating. In addition, we believe a practical guide to standardize the diagnosis and preoperative/perioperative management of patients with OSA should be prepared for Turkish anaesthetists.