1 September 2013 in IEEE Transactions on Biomedical Engineering
Closed-loop control of anesthesia is expected to decrease drug dosage and wake up time while increasing patient safety and decreasing the work load of the anesthesiologist. The potential of closed-loop control in anesthesia has been demonstrated in several clinical studies. One of the challenges in the development of a closed-loop system that can be widely accepted by clinicians and regulatory authorities is the effect of interpatient variability in drug sensitivity. This system uncertainty may lead to unacceptable performance, or even instability of the closed-loop system for some individuals. The development of reliable models of the effect of anesthetic drugs and characterization of the uncertainty is, therefore, an important step in the development of a closed-loop system. Model identification from clinical data is challenging due to limited excitation and the lack of validation data. In this paper, approximate models are validated for controller design by evaluating the predictive accuracy of the closed-loop behavior. A set of 47 validated models that describe the interpatient variability in the response to propofol in children is presented. This model set can be used for robust linear controller design provided that the experimental conditions are similar to the conditions during data collection.
29 August 2017 in IEEE Transactions on Control Systems Technology
This paper describes the design and evaluation of a controller for multi-input single-output (MISO) propofol-remifentanil anesthesia, guided by feedback from a measure of depth-of-hypnosis (DOH). DOH monitors are commonly used in clinical practice to guide anesthetic dosing, however, there is currently no widely accepted nociception monitor to guide remifentanil (analgesic) infusion. Variability in the DOH measure has been associated with insufficient analgesia, and feasibility of closed-loop control of both propofol and remifentanil infusion using DOH feedback has been demonstrated. However, DOH variability does not provide a measure of analgesia in the absence of stimulation. Consequently, control of the opioid-hypnotic balance is lost in control systems relying on DOH feedback alone. The proposed design overcomes this limitation by introducing a second, indirect control objective. This paper defines clinical design specifications to achieve adequate anesthesia in a wide range of clinical cases, proposes a modification of the habituating control framework, and presents methods to translate the clinical objectives into control objectives within this framework. The developed design methodology provides a controller that: 1) meets the clinical objectives; 2) is robust to interpatient variability, both in single-input single-output and MISO operation; 3) is robust to nonlinear drug interactions; 4) gives the user control of the opioid-hypnotic balance in the absence of stimulation and in the presence of input saturation; and 5) improves disturbance rejection following nociceptive stimulation. The MISO system performed as designed in 80 clinical cases.
8 February 2019 in IEEE Transactions on Biomedical Engineering
Objective: The goal of this paper was to optimize robust PID control for propofol anesthesia in children aged 5-10 years to improve performance, particularly to decrease the time of induction of anesthesia while maintaining robustness. Methods: We analyzed results of a previous study conducted by our group to identify opportunities for system improvement. Allometric scaling was introduced to reduce the interpatient variability and a new robust PID controller was designed using an optimization-based method. We evaluated this optimized design in a clinical study involving 16 new cases. Results: The optimized controller design achieved the performance predicted in simulation studies in the design stage. Time of induction of anesthesia was median [Q1, Q3] 3.7 [2.3, 4.1] min and the achieved global score was 13.4 [9.9, 16.8]. Conclusion: Allometric scaling reduces the interpatient variability in this age group and allows for improved closed-loop performance. The uncertainty described by the model set, the predicted closed-loop responses, and the predicted robustness margins are realistic. The system meets the design objectives of improved speed of induction of anesthesia while maintaining robustness and improving clinically relevant system behavior. Significance: Control system optimization and ongoing system improvements are essential to the development of a clinically relevant commercial device. This paper demonstrates the validity of our approach, including system modeling, controller optimization, and pre-clinical testing in simulation.
14 March 2024 in Journal of Manufacturing Processes
1 January 2020 in Biomedical Signal Processing and Control
20 February 2018 in Journal of Clinical Monitoring and Computing