Jairson C. Dinis

Jairson C. Dinis

Auto-generated profile, based on publicly available information

Jairson C. Dinis

ESTG, Polytechnic of Leiria

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Procedia Technology
Verified
Journal Article
Open access
JDJ.C. Dinis
J.C. Dinis
TMT.F. Morais
T.F. Morais
PAP.H.J. Amorim
P.H.J. Amorim
Rui B. RubenRui B. Ruben
Rui B. Ruben
HAHenrique De Amorim Almeida
Henrique De Amorim Almeida
JSJ.V.L. Silva
J.V.L. Silva

1 January 2016 in Procedia CIRP
Verified
Journal Article
Open access
JDJairson C. Dinis
Jairson C. Dinis
TMThiago F. Moraes
Thiago F. Moraes
PAPaulo H.J. Amorim
Paulo H.J. Amorim
Mario Regino Moreno-GuerraMario Regino Moreno-Guerra
Mario Regino Moreno-Guerra
ANAmanda A. Nunes
Amanda A. Nunes
Jorge Vicente Lopes Da SilvaJorge Vicente Lopes Da Silva
Jorge Vicente Lopes Da Silva
The long-term success of implants depends on rapid healing and safe integration with body. In the case of orthopaedic and dental implants it was found that geometry and surface topography are crucial for short and long-term success of the implant, due to its effects in osseointegration. Properties of implant surfaces have been studied in the last decade in a concentrated effort to improve osseointegration process and implant success. Several researchers have proved that roughness of implant surface is related to healing time and integration between the implants and the bone, but the parameters on the surface creation are not fully controllable with current processes. In this work, computational algorithms are proposed for implant surface design in order to control the parameters required for this application. As a result it is presented an open-source software tool, called POMES - Porous and Modifications for Engineering Surfaces -, to design porous/roughness on top of surfaces in any geometry. Additionally, an example model was fabricated using POMES and additive manufacturing

1 January 2023
Verified
Book Chapter
Closed access
PDF file
JDJairson C. Dinis
Jairson C. Dinis
JPJoão Brites Pinto
João Brites Pinto
CCCarlos A. Campos
Carlos A. Campos
MCMário S. Correia
Mário S. Correia
HAHenrique De Amorim Almeida
Henrique De Amorim Almeida
Rui B. RubenRui B. Ruben
Rui B. Ruben

1 January 2017 in International Journal of Signal and Imaging Systems Engineering
Verified
Journal Article
Closed access
JDJ.C. Dinis
J.C. Dinis
TMT.F. Moraes
T.F. Moraes
PAP.H.J. Amorim
P.H.J. Amorim
OAO.H.J. Amorim
O.H.J. Amorim
Jorge Vicente Lopes Da SilvaJorge Vicente Lopes Da Silva
Jorge Vicente Lopes Da Silva
Rui B. RubenRui B. Ruben
Rui B. Ruben
There are several commercial software for medical image dataset segmentation. However, most of them are expensive and not user-friendly. With our proposal of a new open-source software with a simple and specific graphical user interface (GUI), it is easy to segment a foetus from a 3D ultrasound medical image dataset. The segmented portion of images can be converted into a stereolithography (STL) file format for 3D print technologies in order to obtain an accurate physical reproduction of the model segmented. Despite the large number of segmentation algorithms available, this new GUI has three specific possibilities (threshold, region growing and Chan-Vese) in order to keep it simple and efficient. For the same reason, the GUI has just three noise filters available in order to reduce speckle. Besides GUI simplicity, a good segmentation quality was achieved. The main purpose of our proposal is to segment foetal 3D ultrasound images and to make this task quick, easy and efficient.

1 January 2013 in International Journal of Medical Engineering and Informatics
Verified
Journal Article
Closed access
Elza M. M. FonsecaElza M. M. Fonseca
Elza M. M. Fonseca
LBL.M.S. Barreira
L.M.S. Barreira
JDJ.C. Dinis
J.C. Dinis
APAna Pereira
Ana Pereira
The aim of this work is to identify the cortical bone thickness in L4 vertebra, through a digital methodology using computed tomography and an experimental methodology with the rapid prototyping, and to compare with the body mass density for each vertebra in analysis. The study presents clinic results of 16 women from the Northwest of Portugal, with age between 52 and 83 years, collected from May to June 2011. The patients underwent a dual energy X-ray densitometry scan system (Lunar, DPX Pro, daily calibrated) at L4 vertebra for body mass density determination, and simultaneous a lumbar spine computed tomography scan (Lightspeed Plus, GE Medical System) was performed. All clinical data were obtained in a Medical Imaging Centre of Radiology. Discussions of results regarding the measuring of the cortical bone thickness and the relation with body mass density in L4 vertebra are presented in this work. The L4 vertebra is one of the most common spinal sites that lead to chronic lower back pain. The goal of this study is to acquire accurate values, concerning cortical bone thickness, which could improve the prediction of vertebral fractures.

1 January 2017 in International Journal of Signal and Imaging Systems Engineering
Verified
Journal Article
Closed access
RRRui B. Ruben
Rui B. Ruben
JSJ.V.L. Silva
J.V.L. Silva
PAP.H.J. Amorim
P.H.J. Amorim
OAO.H.J. Amorim
O.H.J. Amorim
JDJ.C. Dinis
J.C. Dinis
TMT.F. Moraes
T.F. Moraes
International publishers of academic, scientific and professional journals since 1979.