Shinro Matsuo

Shinro Matsuo

Auto-generated profile, based on publicly available information

Shinro Matsuo

Department of Nuclear Medicine, Kanazawa University Hospital, Kanazawa, Japan

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Circulation Journal
Verified
Journal Article
Closed access
SMShinro Matsuo
Shinro Matsuo
KNKenichi Nakajima
Kenichi Nakajima
MHMinoru Horie
Minoru Horie
INIchiro Nakae
Ichiro Nakae
TNTsunehiko Nishimura
Tsunehiko Nishimura
TIThe J-ACCESS Investigators
The J-ACCESS Investigators
In Japan, Diagnosis Procedure Combination (DPC) of hospitalization health-care costs has been introduced since 2004, and its introduction has been recently expanded also to general hospitals. In such situations, the role of nuclear cardiology as a gatekeeper for the diagnosis of ischemic heart disease is increasingly important. Thus, the present study was designed to determine which clinical risk for hard events after normal single-photon emission computed tomography (SPECT) images, identify the predictors of increased risk in patients with normal SPECT images based on the J-ACCESS study. A total of 4,629 consecutively tested patients who underwent stress (99m)Tc-tetrofosmin SPECT at hospitals in Japan were included in the study. Based on SPECT image data, 1,862 participants had a summed stress score of or=49% in men, EF >or=55% in women), which is defined as selection criteria III (normal perfusion, ESV and EF). During the 3-year follow-up period, there was a total of 211 cardiac events (11.3%) in patients grouped in selection criteria I, 196 cardiac events (11.0%) in patients grouped in selection criteria II, and 189 cardiac events in patients grouped in selection criteria III (10.8%). The annual hard event rates were 0.81%, 0.67% and 0.63% in selection criteria I, II and III, respectively. Cox proportional hazard analysis showed that diabetes mellitus, age and hypertension were independent predictors of all cardiac events in all selection criteria. Normal stress myocardial perfusion imaging in the Japanese population is associated with a low cardiac event risk. The prognosis results of a normal SPECT scan would be useful for better patient management.

1 July 2014 in Journal of Cardiology
Verified
Journal Article
Closed access
SMShinro Matsuo
Shinro Matsuo
KNKenichi Nakajima
Kenichi Nakajima
SKSeigo Kinuya
Seigo Kinuya
MYMasakazu Yamagishi
Masakazu Yamagishi

23 March 2017 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
KOKoichi Okuda
Koichi Okuda
KNKenichi Nakajima
Kenichi Nakajima
SMShinro Matsuo
Shinro Matsuo
SKSoichiro Kashiwaya
Soichiro Kashiwaya
HYHiroto Yoneyama
Hiroto Yoneyama
SKSeigo Kinuya
Seigo Kinuya
Phase analysis of gated myocardial perfusion single-photon emission computed tomography (SPECT) for assessment of left ventricular (LV) dyssynchrony was investigated using the following dedicated software packages: Corridor4DM (4DM), cardioREPO (cREPO), Emory Cardiac Toolbox (ECTb), and quantitative gated SPECT (QGS). The purpose of this study was to evaluate the normal values of 95% histogram bandwidth, phase standard deviation (SD), and entropy and to compare the diagnostic performance of the four software packages. A total of 122 patients with normal myocardial perfusion and cardiac function (58.9 ± 12.3 years, 60 women, ejection fraction (EF) 74.3 ± 5.7%, and end-diastolic volume (EDV) 83.5 ± 3.6 mL) and 34 patients with suspected LV dyssynchrony (64.1 ± 12.2 years, 9 women, EF 52.0 ± 18.0%, and EDV 145.0 ± 6.8 mL) who underwent Tc-99m methoxy-isobutyl-isonitrile/tetrofosmin gated SPECT were retrospectively evaluated. Dyssynchrony indices of the 95% histogram bandwidth, phase SD, and entropy were computed with the four software programs. Diagnostic performance of LV phase dyssynchrony assessments was determined by receiver operator characteristic (ROC) analysis. The area under the ROC curve (AUC) was used to compare the software programs. The optimal cutoff point was determined by ROC curve based on the Youden index. The average of normal bandwidth significantly differed among the four software programs except in the comparison of 4DM and ECTb. Moreover, the normal phase SD significantly differed among the four software programs except in the comparison of cREPO and ECTb. The software programs showed high correlation levels for bandwidth, phase SD, and entropy (r ≥ 0.73, p < 0.001). ROC AUCs of bandwidth, phase SD, and entropy were ≥0.850, ≥0.858, and ≥0.900, respectively. Moreover, the ROC AUCs of bandwidth, phase SD, and entropy did not significantly differ among the four software programs. Optimal cutoff points for phase parameters were 24°–42° for bandwidth, 8.6°–15.3° for phase SD, and 31–48% for entropy. Although the optimal cutoff value for determining LV phase dyssynchrony by ROC analysis varied depending on the use of the different software programs, all software programs can be used reliably for phase dyssynchrony analysis.

29 March 2015 in Annals of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
SMShinro Matsuo
Shinro Matsuo
KNKenichi Nakajima
Kenichi Nakajima
MOMasahisa Onoguchi
Masahisa Onoguchi
HWHiroshi Wakabayash
Hiroshi Wakabayash
KOKoichi Okuda
Koichi Okuda
SKSeigo Kinuya
Seigo Kinuya

7 November 2008 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
SMShinro Matsuo
Shinro Matsuo
KNKenichi Nakajima
Kenichi Nakajima
KOKoichi Okuda
Koichi Okuda
MKMasaya Kawano
Masaya Kawano
TITakehiro Ishikawa
Takehiro Ishikawa
SKSeigo Kinuya
Seigo Kinuya
Although the heart-to-mediastinum (H/M) ratio in a planar image has been used for practical quantification in 123I-metaiodobenzylguanidine (MIBG) imaging, standardization of the parameter is not yet established. We hypothesized that the value of the H/M ratio could be standardized to the various camera–collimator combinations. Standard phantoms consisting of the heart and mediastinum were made. A low-energy high-resolution (LEHR) collimator and a medium-energy (ME) collimator were used. We examined multi-window correction methods with 123I- dual-window (IDW) acquisition, and planar images were obtained with IDW correction and the LEHR collimator. The images were obtained using the following gamma camera systems: GCA 9300A (Toshiba, Tokyo), E.CAM Signature (Toshiba/Siemens, Tokyo) and Varicam (GE, Tokyo). Cardiac phantom studies demonstrated that contamination of the H/M count ratio was greater with the LEHR collimator and least with the ME collimator. The corrected H/M ratio with the LEHR collimator was similar to that with ME collimators. The uncorrected H/M ratio with the ME collimator was linearly related to the H/M ratio with IDW correction with the LEHR collimator. The relationship between the uncorrected H/M ratios determined with the LEHR (E.CAM) and the ME collimators was y = 0.56x + 0.49, where y = H/M ratio with the E.CAM and x = H/M ratio with the ME collimator. The average normal values for the low-energy collimator (n=18) were 2.2±0.2 (initial H/M ratio) and 2.42±0.2 (delayed H/M ratio), and for the low/medium-energy (LME) collimator (n=14) were 2.63±0.25 (initial H/M ratio) and 2.87±0.19 (delayed H/M ratio). H/M ratios in previous clinical studies using LEHR collimators are comparable to those with ME collimators. The IDW-corrected H/M ratios determined with the LEHR collimator were similar to those determined with the ME collimator. This finding could make it possible to standardize the H/M ratio in planar imaging among various collimators in the clinical setting.

22 September 2017 in Annals of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
KNKenichi Nakajima
Kenichi Nakajima
KOKoichi Okuda
Koichi Okuda
MMMitsuru Momose
Mitsuru Momose
SMShinro Matsuo
Shinro Matsuo
CKChisato Kondo
Chisato Kondo
AVA. Hans Vija
A. Hans Vija
IQ·SPECT (Siemens Medical Solutions) is a solution for high-sensitivity and short-time acquisition imaging of the heart for a variable angle general purpose gamma camera. It consists of a multi-focal collimator, a cardio-centric orbit and advanced iterative reconstruction, modeling the image formation physics accurately. The multi-focal collimator enables distance-dependent enlargement of the center region while avoiding truncation at the edges. With the specified configuration and a cardio-centric orbit it can obtain a fourfold sensitivity increase for the heart at the center of the scan orbit. Since IQ·SPECT shows characteristic distribution patterns in the myocardium, appropriate acquisition and processing conditions are required, and normal databases are convenient for quantification of both normal and abnormal perfusion images. The use of prone imaging can be a good option when X-ray computed tomography (CT) is not available for attenuation correction. CT-based attenuation correction changes count distribution significantly in the inferior wall and around the apex, hence image interpretation training and additional use of normal databases are recommended. Recent reports regarding its technology, Japanese Society of Nuclear Medicine working group activities, and clinical studies using 201Tl and 99mTc-perfusion tracers in Japan are summarized.