Yichu Jin

Yichu Jin

Auto-generated profile, based on publicly available information

Yichu Jin

John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2024 in Science Robotics
Verified
Journal Article
Closed access
YZYu Meng Zhou
Yu Meng Zhou
CHCameron J. Hohimer
Cameron J. Hohimer
HYHarrison T. Young
Harrison T. Young
CMConnor M. McCann
Connor M. McCann
DPDavid Pont-Esteban
David Pont-Esteban
CWConor J. Walsh
Conor J. Walsh
Repetitive overhead tasks during factory work can cause shoulder injuries resulting in impaired health and productivity loss. Soft wearable upper extremity robots have the potential to be effective injury prevention tools with minimal restrictions using soft materials and active controls. We present the design and evaluation of a portable inflatable shoulder wearable robot for assisting industrial workers during shoulder-elevated tasks. The robot is worn like a shirt with integrated textile pneumatic actuators, inertial measurement units, and a portable actuation unit. It can provide up to 6.6 newton-meters of torque to support the shoulder and cycle assistance on and off at six times per minute. From human participant evaluations during simulated industrial tasks, the robot reduced agonist muscle activities (anterior, middle, and posterior deltoids and biceps brachii) by up to 40% with slight changes in joint angles of less than 7% range of motion while not increasing antagonistic muscle activity (latissimus dorsi) in current sample size. Comparison of controller parameters further highlighted that higher assistance magnitude and earlier assistance timing resulted in statistically significant muscle activity reductions. During a task circuit with dynamic transitions among the tasks, the kinematics-based controller of the robot showed robustness to misinflations (96% true negative rate and 91% true positive rate), indicating minimal disturbances to the user when assistance was not required. A preliminary evaluation of a pressure modulation profile also highlighted a trade-off between user perception and hardware demands. Finally, five automotive factory workers used the robot in a pilot manufacturing area and provided feedback.

9 July 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
YJYichu Jin
Yichu Jin
JAJonathan Tyler Alvarez
Jonathan Tyler Alvarez
ESElizabeth L. Suitor
Elizabeth L. Suitor
KSKrithika Swaminathan
Krithika Swaminathan
ACAndrew Chin
Andrew Chin
CWConor J. Walsh
Conor J. Walsh
The human body constantly experiences mechanical loading. However, quantifying internal loads within the musculoskeletal system remains challenging, especially during unconstrained dynamic activities. Conventional measures are constrained to laboratory settings, and existing wearable approaches lack muscle specificity or validation during dynamic movement. Here, we present a strategy for estimating corresponding joint torque from muscles with different architectures during various dynamic activities using wearable A-mode ultrasound. We first introduce a method to track changes in muscle thickness using single-element ultrasonic transducers. We then estimate elbow and knee torque with errors less than 7.6% and coefficients of determination (R2) greater than 0.92 during controlled isokinetic contractions. Finally, we demonstrate wearable joint torque estimation during dynamic real-world tasks, including weightlifting, cycling, and both treadmill and outdoor locomotion. The capability to assess joint torque during unconstrained real-world activities can provide new insights into muscle function and movement biomechanics, with potential applications in injury prevention and rehabilitation.

2 August 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
JAJames Arnold
James Arnold
PPPrabhat Pathak
Prabhat Pathak
YJYichu Jin
Yichu Jin
DPDavid Pont-Esteban
David Pont-Esteban
CMConnor M. McCann
Connor M. McCann
CWConor J. Walsh
Conor J. Walsh
Portable wearable robots offer promise for assisting people with upper limb disabilities. However, movement variability between individuals and trade-offs between supportiveness and transparency complicate robot control during real-world tasks. We address these challenges by first developing a personalized ML intention detection model to decode user’s motion intention from IMU and compression sensors. Second, we leverage a physics-based hysteresis model to enhance control transparency and adapt it for practical use in real-world tasks. Third, we combine and integrate these two models into a real-time controller to modulate the assistance level based on the user’s intention and kinematic state. Fourth, we evaluate the effectiveness of our control strategy in improving arm function in a multi-day evaluation. For 5 individuals post-stroke and 4 living with ALS wearing a soft shoulder robot, we demonstrate that the controller identifies shoulder movement with 94.2% accuracy from minimal change in the shoulder angles (elevation: 3.4°, depression: 1.7°) and reduces arm-lowering force by 31.9% compared to a baseline controller. Furthermore, the robot improves movement quality by increasing their shoulder elevation/depression (17.5°), elbow (10.6°) and wrist flexion/extension (7.6°) ROMs; reducing trunk compensation (up to 25.4%); and improving hand-path efficiency (up to 53.8%).

11 April 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
DKDaekyum Kim
Daekyum Kim
YJYichu Jin
Yichu Jin
HCHaedo Cho
Haedo Cho
TJTruman Jones
Truman Jones
YZYu Meng Zhou
Yu Meng Zhou
CWConor J. Walsh
Conor J. Walsh
Inertial measurement units offer a cost-effective, portable alternative to lab-based motion capture systems. However, measuring joint angles and movement trajectories with inertial measurement units is challenging due to signal drift errors caused by biases and noise, which are amplified by numerical integration. Existing approaches use anatomical constraints to reduce drift but require body parameter measurements. Learning-based approaches show promise but often lack accuracy for broad applications (e.g., strength training). Here, we introduce the Activity-in-the-loop Kinematics Estimator, an end-to-end machine learning model incorporating human behavioral constraints for enhanced kinematics estimation using two inertial measurement units. It integrates activity classification with kinematics estimation, leveraging limited movement patterns during specific activities. In dynamic scenarios, our approach achieved trajectory and shoulder joint angle errors under 0.021 m and \(6.5^\circ\), respectively, 52% and 17% lower than errors without including activity classification. These results highlight accurate motion tracking with minimal inertial measurement units and domain-specific context.

19 May 2024 in Advanced Materials Technologies
Verified
Journal Article
Closed access
JAJonathan Tyler Alvarez
Jonathan Tyler Alvarez
AMAriane de Marcillac
Ariane de Marcillac
YJYichu Jin
Yichu Jin
LGLucas F. Gerez
Lucas F. Gerez
SASeun Araromi
Seun Araromi
CWConor J. Walsh
Conor J. Walsh

6 April 2026 in Nature Sensors
Verified
Journal Article
Closed access
PDF file
YJYichu Jin
Yichu Jin
YZYu Meng Zhou
Yu Meng Zhou
PPPrabhat Pathak
Prabhat Pathak
RWRobert J. Wood
Robert J. Wood
CWConor J. Walsh
Conor J. Walsh