Kun Tan

Dr. Kun Tan

School of Electrical Engineering and Automation, Anhui University, Hefei, Anhui, China
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WZWuyu Zhang
Wuyu Zhang
Kun TanKun Tan
Kun Tan
BJBing Ji
Bing Ji
LQLei Qi
Lei Qi
XCXiang Cui
Xiang Cui
LDLuchun Du
Luchun Du
Condition monitoring of insulated gate bipolar transistor (IGBT) modules is an effective way to improve the transient performance and reliability of modular multilevel converters (MMC). This article proposes a novel bond wire failure monitoring method for the multichip IGBT modules in the MMC half-bridge submodule (SM) structure. The collector voltage undershoot V CA(np) of the complementary IGBT switch is measured during the turn- off switching transition of the controlled IGBT switch. V CA(np) is sensitive to the induced voltage over the stray inductance of the IGBT bond wires and provides high sensitivity as a health indicator. The non-intrusive measurement technique is demonstrated using a half-bridge circuit during the turn- off transition of the controlled IGBT, while its complementary switch (i.e., the device under test) is in the off state. Theoretical analysis and experimental results show that the parametric drift due to wire bonding failures can be effectively monitored with high specific relative sensitivity and granularity. To ensure its effectiveness in practical applications, the influence of load current, SM capacitor voltage, and junction temperature is discussed. In addition, a readout circuit is designed featuring the integrated desaturation detection and voltage peak detection, which offers both the short-term overcurrent fault protection and long-term bond wire aging monitoring functions.

20 December 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
WZWuyu Zhang
Wuyu Zhang
LQLei Qi
Lei Qi
Kun TanKun Tan
Kun Tan
BJBing Ji
Bing Ji
XZXiangyu Zhang
Xiangyu Zhang
XCXiang Cui
Xiang Cui
Despite that many temperature-sensitive electrical parameters (TSEPs) have been discovered for the online estimation of the junction temperature of IGBT devices, their wide adoption in the field is yet to come. This is because they are most susceptible to both the aging status and operating points of IGBTs, which can result in inaccurate results if not attended. In this study, a novel dynamic TSEP, the gate voltage undershoot V GE(np) of the complementary IGBT switch, is proposed. It is based on the crosstalk effect and measured during the turn- off switching transition of the controlled IGBT switch for its temperature estimation. Its monotonic temperature dependence has been identified with implications for the changing load current and bus voltage, which are experimentally verified using a 1200 V/450 A IGBT module. The theoretical analysis and experimental results also show that V GE(np) is independent of bond wire failures while providing comparatively high relative sensitivity. The MMC power equivalent experimental results are given to verify the feasibility of the proposed method in commercial engineering applications. Finally, the multivariate linear regression method is used to improve the ability to estimate the IGBT's temperature by accounting for the operating point.

16 September 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
WZWuyu Zhang
Wuyu Zhang
Kun TanKun Tan
Kun Tan
BJBing Ji
Bing Ji
LQLei Qi
Lei Qi
XCXiang Cui
Xiang Cui
XZXiangyu Zhang
Xiangyu Zhang
Introducing bond wire diagnosis for multichip insulated gate bipolar transistor (IGBT) modules is key to the health monitoring of modular multilevel converters (MMCs), which allow for improved field robustness, reliability, and reduced maintenance cost. This article leverages the crosstalk phenomenon during switching transitions to detect the chip open-circuit faults caused by the bond wire lift-off using typical half-bridge IGBT modules in a multichip-parallel configuration. The cycle-controlled, nonintrusive measurement is conducted under normal operation, when the device under test is in OFF-state and its complementary switch is during switching transitions. Two specialized health-sensitive parameters arising from the dynamic gate loop waveforms are identified and evaluated, including: 1) the gate voltage $V_{\mathrm {GE(t3)}}$ when the declining collector voltage reaches zero and 2) the negative peak gate voltage $V_{\mathrm {GE(t4)}}$ . The sensitivity and stability of these two parameters are compared through theoretical analysis, circuit simulation, and practical verification. The results show that $V_{\mathrm {GE(t4)}}$ is more suitable for online monitoring, while $V_{\mathrm {GE(t3)}}$ is more sensitive than $V_{\mathrm {GE(t4)}}$ . With managed complexity in gate drives, this proposed health awareness approach is feasible in the submodules of MMC applications, but it can also be used in other power converter topologies incorporating the half-bridge structure.

3 October 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MLMeng Luo
Meng Luo
Kun TanKun Tan
Kun Tan
XTXi Tang
Xi Tang
Cungang HuCungang Hu
Cungang Hu
ZLZekun Li
Zekun Li
Wenping CaoWenping Cao
Wenping Cao
Junction temperature estimation with high precision is crucial to the reliability and safe operating of silicon-carbide (SiC) metal-oxide-semiconductor field-effect transistors (MOSFETs). Approaches using temperature-sensitive electrical parameters (TSEPs) are widely employed in the monitoring, offering benefits of non-invasiveness and fast thermal response. This paper proposes a load-independent junction temperature model incorporating three TSEPs, the peak drain voltage ( V DS,pk ), the peak drain current ( I D,pk ), and the turn-on delay time ( t d,on ). This model eliminates the impact of both load voltage and current, thus improving the estimating accuracy and anti-interference ability compared with other approaches relying on single or fewer TSEPs. Initially, four typical TSEPs and their dependencies on junction temperature and load conditions are established theoretically. Then, the proposed modeling method via combined TSEPs is introduced. Its effectiveness and advantage are experimentally validated with double-pulse tests. Under various loading conditions, the conventional single TSEP method exhibits a mean absolute percentage error up to 22.56%, while the proposed method effectively reduces it down to 6.31%.

10 September 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HLHaoran Li
Haoran Li
TLTong Lei
Tong Lei
Cungang HuCungang Hu
Cungang Hu
XZXirui Zhu
Xirui Zhu
Kun TanKun Tan
Kun Tan
Wenping CaoWenping Cao
Wenping Cao
It is extremely important to use synchronous rectifier (SR) as the diode forward voltage of SiC mosfet s may be up to six times higher than Si mosfet s, which causes much higher conduction loss. Conventional CLLC SR typically uses detection circuits or builds complex models, but they are susceptible to high dv/dt generated from SiC devices, or have difficulty in implementing SR online due to the complex numerical calculation. A digital real-time computation SR algorithm is proposed for bidirectional SiC CLLC converter. Analytic models in the time domain are constructed to calculate the SR conduction time online. It not only achieves low conduction loss by optimizing the on-time of SR MOSFETs, but also provides high immunity to the high switching frequency noise. A prototype of 300-kHz 6.6-kW SiC bidirectional CLLC charger was built to verify the proposed control. With the proposed SR, the CLLC efficiencies are up to 97.56% and 97.75% at full load in the forward and reverse modes, respectively. Moreover, the CLLC full load efficiencies improves 0.42% and 0.35% over the conventional SR control in the forward and reverse modes. The power density of proposed charger increment is also up to 20% over Wolfspeed charger.

30 May 2024 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
JJJunsong Jiang
Junsong Jiang
XTXi Tang
Xi Tang
Kun TanKun Tan
Kun Tan
ZHZhihao Hu
Zhihao Hu
MTMohan Tian
Mohan Tian
Wenping CaoWenping Cao
Wenping Cao
Dynamic threshold voltage shifts (DTVS) in silicon carbide (SiC) MOSFETs are investigated using an ultrafast characterization method that incorporates nanosecond-range switching. A positive gate bias causes a positive DTVS and a negative gate bias causes a negative DTVS, which is observed within a timescale range of 40 ns–1 s. At a gate bias of $-$ 10 V, the negative DTVS can reach approximately $-$ 4 V, which changes the threshold voltage from positive to negative. A mechanism involving carrier trapping at/near the SiO $_{\text{2}}$ /SiC interface is proposed. Then, the impact of DTVS on dynamic behavior is evaluated by a double-pulse test (DPT) under different OFF-state gate biases ( V $_{\text{GS,OFF}}$ ). A negative DTVS causes the channel turn-on earlier, increasing the current overshoot ( I $_{\text{OS}}$ ) during the turn-on process. As V $_{\text{GS,OFF}}$ decreases from 0 to $-$ 10 V, the turn-on loss ( E $_{\text{ON}}$ ) increases by 11.2% at a load current of 10 A. Moreover, the E $_{\text{ON}}$ changes from an increase to a decrease when the turn-on gate resistance ( R $_{\text{G,ON}}$ ) increases from 10 to 50 $\Omega$ . Therefore, for a specific gate driving condition, an optimized R $_{\text{G,ON}}$ can be chosen to compromise the DTVS-induced E $_{\text{ON}}$ change.