28 November 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
A linear piezoelectric micromachined ultrasound transducer (PMUT) array was fabricated and integrated into a device for photoacoustic imaging (PAI) of tissue phantoms. The PMUT contained 65 array elements, with each element having 60 diaphragms of 60 μm diameter and 75 μm pitch. A lead zirconate titanate (PZT) thin film was used as the piezoelectric layer. The in-air vibration response of the PMUT array elements showed a first mode resonance between 6 and 8 MHz. Hydrophone measurements showed 16.2 kPa average peak ultrasound pressure output at 7.5 mm from one element excited with 5 Vpp input. A receive sensitivity of ~0.48 mV/kPa was observed for a PMUT array element with 0 dB gain. The PMUT array was bonded to a custom-printed circuit board to enable compact integration with an optical fiber bundle for PAI. A broad photoacoustic bandwidth of ~89% was observed for the photoacoustic response captured from absorbing pencil lead targets. Linear scanning of a single element of a PMUT array was performed on different tissue phantoms embedded with light-absorbing targets to successfully demonstrate B-mode PAI using PMUTs.
29 October 2019 in Optics Letters
This Letter demonstrates lithium niobate ()-based transparent ultrasound transducers (TUTs) for photoacoustic imaging applications. The TUTs were fabricated by coating the top and bottom surfaces of a 0.25 mm thick wafer with transparent indium-tin-oxide (ITO) electrodes. The resulting transducers showed optical transparency in the wavelength range of 690–970 nm. The TUTs had a resonant frequency of 14.5 MHz and photoacoustic bandwidth. The versatility of the TUT approach is demonstrated by introducing two different transparent photoacoustic imaging (PAI) geometries. In one method, which suits endoscopy applications, an optical fiber of a laser diode is directly fixed on the backside of a 2.5 mm diameter TUT, and the fiber-TUT device is raster scanned to form 3D photoacoustic images. In the second method, which suits high-throughput applications, a free-space optical-only raster scanning of the laser fiber across a planar TUT yielded 3D photoacoustic images. The proposed TUT approach is low in cost, easy to manufacture, compatible with conventional clinical ultrasound electronics, and scalable for different configurations, including 2D TUT arrays to achieve real-time 3D high-throughput PAI.
11 June 2019 in IEEE Transactions on Biomedical Circuits and Systems
In order to improve the spatial resolution of transcranial focused ultrasound stimulation (tFUS), we have recently proposed microscopic ultrasound stimulation (μUS). In μUS, either an electronically phased array of ultrasound transducers or several millimeter-sized focused transducers are placed on the brain surface or sub-millimeter-sized transducers are implanted inside the brain tissue to steer and deliver a focused ultrasound pressure directly to the neural target. A key element in both tFUS and μUS is the ultrasound transducer that converts electrical power to acoustic pressure. The literature lacks a comprehensive study (in a quantitative manner) of the transducer characteristics, such as dimension, focusing, acoustic matching, backing material, and sonication frequency (fp), in the μUS. This paper studies the impact of these design parameters on the acoustic beam profile of millimeter-sized transducers with the emphasis on the stimulation spatial resolution and energy efficiency, which is defined as the μUS figure-of-merit (FoM). For this purpose, disc-shaped focused and unfocused piezoelectric (PZT-5A) transducers with different dimension (diameter, thickness), backing material (PCB, air) and acoustic matching in the frequency range of 2.2-9.56 MHz were fabricated. Our experimental studies with both water and sheep brain phantom medium demonstrate that acoustically matched focused transducers with high quality factor are desirable for μUS, as they provide fine spatial resolution and high acoustic intensities with low input electrical power levels (i.e., high FoM).
2 July 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Lead zirconate titanate (PZT) based piezoelectric micromachined ultrasonic transducers (PMUTs) for particle manipulation applications were designed, fabricated, characterized and tested. The PMUTs had a diaphragm diameter of 60 lm, a resonant frequency of ∼ 8 MHz and an operational bandwidth of 62.5%. Acoustic pressure output in water was 9.5 kPa at 7.5 mm distance from a PMUT element excited with a unipolar waveform at 5 Vpp. The element consisted of 20 diaphragms connected electrically in parallel. Particle trapping of 4 lm silica beads was shown to be possible with 5 Vpp unipolar excitation. Trapping of multiple beads by a single element and deterministic control of particles via acoustophoresis without the assistance of microfluidic flow were demonstrated. It was found that the particles move towards diaphragm areas of highest pressure, in agreement with literature and simulations. Unique bead patterns were generated at different driving frequencies and were formed at frequencies up to 60 MHz, much higher than the operational bandwidth. Levitation planes were generated above 30 MHz driving frequency.
24 November 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Optical photons undergo strong scattering when propagating beyond 1-mm deep inside biological tissue. Finding the origin of these diffused optical wavefronts is a challenging task. Breaking through the optical diffusion limit, photoacoustic (PA) imaging (PAI) provides high-resolution and label-free images of human vasculature with high contrast due to the optical absorption of hemoglobin. In real-time PAI, an ultrasound transducer array detects PA signals, and B-mode images are formed by delay-and-sum or frequency-domain beamforming. Fundamentally, the strength of a PA signal is proportional to the local optical fluence, which decreases with the increasing depth due to depth-dependent optical attenuation. This limits the visibility of deep-tissue vasculature or other light-absorbing PA targets. To address this practical challenge, an encoder-decoder convolutional neural network architecture was constructed with custom modules and trained to identify the origin of the PA wavefronts inside an optically scattering deep-tissue medium. A comprehensive ablation study provides strong evidence that each module improves the localization accuracy. The network was trained on model-based simulated PA signals produced by 16 240 blood-vessel targets subjected to both optical scattering and Gaussian noise. Test results on 4600 simulated and five experimental PA signals collected under various scattering conditions show that the network can localize the targets with a mean error less than 30 microns (standard deviation 20.9 microns) for targets below 40-mm imaging depth and 1.06 mm (standard deviation 2.68 mm) for targets at a depth between 40 and 60 mm. The proposed work has broad applications such as diffused optical wavefront shaping, circulating melanoma cell detection, and real-time vascular surgeries (e.g., deep-vein thrombosis).