Including dispersion slope analysis derived from two-dimensional shear-wave elastography did not improve the diagnostic performance in detecting liver necroinflammation, fibrosis, or steatosis in 1... Background Little is known about the benefits of the use of dispersion slope (DS) as a viscosity-related parameter derived from two-dimensional (2D) shear-wave elastography (SWE) in the stratificat...
Two-dimensional shear-wave elastography is valuable in predicting liver-related events in patients with well-compensated cirrhosis and chronic hepatitis B viral infection; its predictive accuracy i... Background Liver stiffness measurement has been proposed as a noninvasive marker for predicting liver-related complications of cirrhosis. Purpose To evaluate the predictive value of liver stiffness...
Purpose: This study compared the efficacy of heat insulation between 5% dextrose and 0.9% saline in radiofrequency ablation (RFA). Accordingly, temperature variations and maximum temperatures were assessed at identical distances and heat field distributions.Methods: Cubes of porcine liver tissue, measuring 10 mm across, were selected to precisely align the ablation boundary with the tissue boundary. An 18-gauge electrode with a 7-mm tip was inserted into each cube (10 per group) in a stainless-steel cup containing 40 mL of 5% dextrose or 0.9% saline. Fixed ablation was performed for 3 minutes using continuous mode at 30 W, simulating the typical thermal environment during thyroid RFA. Real-time temperature measurements were recorded by sensors positioned 0, 1, 3, and 5 mm from the cube’s edge. A comparative analysis was conducted to assess the maximum temperature, temperature variation, and duration of temperatures exceeding 42℃.Results: In both groups, the temperature curve declined with increasing distance from the edge of the ablated tissue. However, 0.9% saline exhibited higher maximum temperatures at 1, 3, and 5 mm compared to 5% dextrose (1 mm: 44.55°C±5.25°C vs. 34.68°C±3.07°C; 3 mm: 39.64°C±2.53°C vs. 29.22°C±2.21°C; 5 mm: 38.86°C±2.14°C vs. 28.74°C±2.51°C; all P<0.001). Considering a nerve injury threshold of 42°C, the 0.9% saline also displayed a greater proportion of samples reaching this temperature and a longer duration of temperatures exceeding it (P<0.05).Conclusion: The heat insulation efficacy of 5% dextrose at 1-5 mm exceeds that of 0.9% saline at identical distances and in a common thermal environment during thyroid RFA.
13 January 2022 in Journal of Clinical and Translational Hepatology
Acute-on-chronic liver failure (ACLF) is associated with very high mortality. Accurate prediction of prognosis is critical in navigating optimal treatment decisions to improve patient survival. This study was aimed to develop a new nomogram integrating two-dimensional shear wave elastography (2D-SWE) values with other independent prognostic factors to improve the precision of predicting ACLF patient outcomes.