Ahda Pionkoski Grilo

Ahda Pionkoski Grilo

Auto-generated profile, based on publicly available information

Ahda Pionkoski Grilo

Center for Engineering and Applied Social Sciences, Federal University of ABC, Santo Andre, Brazil

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
VMV.L. Merlin
V.L. Merlin
RSR.C. Santos
R.C. Santos
AGA.P. Grilo
A.P. Grilo
JVJose Carlos de Melo Vieira
Jose Carlos de Melo Vieira
DCDenis Vinicius Coury
Denis Vinicius Coury
MOMario Oleskovicz
Mario Oleskovicz

29 October 2007 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
AGAhda Pionkoski Grilo
Ahda Pionkoski Grilo
AMAlexandre de Assis Mota
Alexandre de Assis Mota
LMLia Mota
Lia Mota
WFWalmir Freitas
Walmir Freitas
This paper presents an analytical method for analysis of large-disturbance stability of squirrel-cage rotor induction generators. The proposed analytical method is based on the steady-state equivalent circuit of the induction generator and on the concepts of stable and unstable electrical-mechanical equilibrium points, which are calculated in the electrical and mechanical torque versus rotor speed space. This analytical approach sheds light on theoretical issues related to the stability of induction generators. Moreover, this method can be used as a guide to significantly reduce the simulation efforts necessary to assess the large-disturbance stability of induction generators. The method has been validated by comparing the results obtained by the analytical method with those determined by extensive dynamic simulation results through a sensitivity study. In the dynamic simulations, the induction generators are represented by a fourth-order algebraic-differential model. In addition, a simple approach is proposed for assessing the fault ride-through capability of induction generators.

24 October 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
DEDanny Espín-Sarzosa
Danny Espín-Sarzosa
RPRodrigo Palma
Rodrigo Palma
CCClaudio A. Cañizares
Claudio A. Cañizares
UAUdaya Annakkage
Udaya Annakkage
MEMarcelo Elizondo
Marcelo Elizondo
JRJames T. Reilly
James T. Reilly
This document is a summary of a report prepared by the IEEE PES Task Force (TF) on Microgrid (MG) Dynamic Modeling, IEEE Power and Energy Society, Tech. Rep. PES-TR106, 2023. In this paper, the major issues and challenges in microgrid modeling for stability analysis are discussed, and a review of state-of-the-art modeling approaches and trends is presented. In the context of the IEEE 1547 standard, the document covers issues associated with component models for MG dynamic studies and simulations, including generator and grid modeling, full and average converter models, unbalanced and balanced system conditions, dynamic and static loads, protection requirements, and detailed and simplified controls considering communications delays, packet losses, and security issues. Considering the future integration of grids and MGs to form broad integrated networks, a discussion is presented of the use of phasor vis-à-vis electromagnetic transient simulation tools for MG dynamic stability studies, as well as modeling scale-up issues and MG equivalent models. Specifically white-, grey-, and black-box models, are presented. This TF paper and companion report constitute a modeling guide for R&D groups working on developments and standards of MGs with a focus on stability issues.

12 April 2010 in Energies
Verified
Journal Article
Open access
PDF file
MSMauricio B C Salles
Mauricio B C Salles
KHKay Hameyer
Kay Hameyer
Jose Roberto CardosoJose Roberto Cardoso
Jose Roberto Cardoso
AGAhda. P. Grilo
Ahda. P. Grilo
CRClaudia Rahmann
Claudia Rahmann
In the last 15 years, the use of doubly fed induction machines in modern variable-speed wind turbines has increased rapidly. This development has been driven by the cost reduction as well as the low-loss generation of Insulated Gate Bipolar Transistors (IGBT). According to new grid code requirements, wind turbines must remain connected to the grid during grid disturbances. Moreover, they must also contribute to voltage support during and after grid faults. The crowbar system is essential to avoid the disconnection of the doubly fed induction wind generators from the network during faults. The insertion of the crowbar in the rotor circuits for a short period of time enables a more efficient terminal voltage control. As a general rule, the activation and the deactivation of the crowbar system is based only on the DC-link voltage level of the back-to-back converters. In this context, the authors discuss the critical rotor speed to analyze the instability of doubly fed induction generators during grid faults.

18 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
LGLuis Alejandro Gutierrez Gomez
Luis Alejandro Gutierrez Gomez
AGAhda P. Grilo
Ahda P. Grilo
MSMauricio B C Salles
Mauricio B C Salles
Alfeu J. Sguarezi FilhoAlfeu J. Sguarezi Filho
Alfeu J. Sguarezi Filho
This paper presents a novel methodology for frequency control of a microgrid through doubly fed induction generator (DFIG) employing battery energy storage system (BESS) and droop control. The proposed microgrid frequency control is the result of the active power injection from the droop control implemented in the grid side converter (GSC) of the DFIG, and the BESS implemented in the DC link of the back-to-back converter also in the DFIG. This methodology guarantees the battery system charge during operation of the connected DFIG in the network, and the frequency control in microgrid operation after an intentional disturbance. In order for the DFIG to provide frequency support to the microgrid, the best-performing droop gain value is selected. Afterwards its performance is evaluated individually and together with the power injected by the battery. The power used for both battery charging and frequency support is managed and processed by the GSC without affecting the normal operation of the wind system. The simulation tests are performed using Matlab/Simulink toolbox.

27 October 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
NHNolman Barroso Hartmann
Nolman Barroso Hartmann
RSRicardo Caneloi dos Santos
Ricardo Caneloi dos Santos
AGAhda Pionkoski Grilo
Ahda Pionkoski Grilo
JVJose Carlos de Melo Vieira
Jose Carlos de Melo Vieira
Recently, it has been verified by simulation results that the ability of recognizing and classifying patterns by artificial neural network can be successfully used for anti-islanding protection of distributed synchronous generators. However, since this type of protection differs from the available commercial relays, it is important to test the algorithm performance implemented in hardware. So, this paper presents a performance evaluation of the hardware implementation of an ANN-based algorithm for anti-islanding protection of distributed generators. For the evaluation process, a complete digital relay architecture is developed in LabVIEW, thus allowing its implementation in the commercial real-time platform cRIO-9025/cRIO-9018. The proposed scheme is tested under real conditions by means of the CMC-256-plus test set, as performed for conventional intelligent electronic devices. The proposed algorithm implemented in hardware shows high effectiveness, detecting all islanding conditions within 1 s, sharing the same good performance verified by computational simulations. The algorithm implementation shows robustness, as it remains blocked for other power grid disturbances, such as frequency variation in the grid utility, massive connection or load relief.