Ricardo Caneloi dos Santos

Ricardo Caneloi dos Santos

Auto-generated profile, based on publicly available information

Ricardo Caneloi dos Santos

Federal University of ABC, Santo André, Brazil

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2020 in IEEE Access
Verified
Journal Article
Open access
YBYunfei Bai
Yunfei Bai
JLJIANWEI LI
JIANWEI LI
Hongwen HeHongwen He
Hongwen He
RSRicardo Caneloi Dos Santos
Ricardo Caneloi Dos Santos
Qingqing YangQingqing Yang
Qingqing Yang
This paper proposes a multi-dimensional size optimization framework and a hierarchical energy management strategy (HEMS) to optimize the component size and the power of a plug-in hybrid electric vehicle (PHEV) with the hybrid energy storage system (HESS). In order to evaluate the performance of size optimization and power optimization, a PHEV with a battery energy storage system (BESS) is used as a comparison reference, and the dynamic programming (DP) algorithm is set as a benchmark for comparison. The size optimization method explores the optimal configuration of the system, including the maximum power of the system, the maximum power and capacity of the battery, and the maximum power and capacity of the supercapacitor (SC). Compared with the BESS, the size-optimized HESS reduces the capacity of the system by 31.3% and improves the economy by 37.8%. The HEMS can simultaneously optimize vehicle fuel consumption and suppress battery aging. Its upper layer uses the DP algorithm to optimize fuel economy, and the lower layer apply the linear programming (LP) method to improve battery life. Based on the size optimization results and HEMS, compared with the benchmark, the battery aging rate has been reduced by 48.9%, and the vehicle economy has increased by 21.2%.

27 October 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
NHNolman Barroso Hartmann
Nolman Barroso Hartmann
RSRicardo Caneloi dos Santos
Ricardo Caneloi dos Santos
AGAhda Pionkoski Grilo
Ahda Pionkoski Grilo
JVJose Carlos de Melo Vieira
Jose Carlos de Melo Vieira
Recently, it has been verified by simulation results that the ability of recognizing and classifying patterns by artificial neural network can be successfully used for anti-islanding protection of distributed synchronous generators. However, since this type of protection differs from the available commercial relays, it is important to test the algorithm performance implemented in hardware. So, this paper presents a performance evaluation of the hardware implementation of an ANN-based algorithm for anti-islanding protection of distributed generators. For the evaluation process, a complete digital relay architecture is developed in LabVIEW, thus allowing its implementation in the commercial real-time platform cRIO-9025/cRIO-9018. The proposed scheme is tested under real conditions by means of the CMC-256-plus test set, as performed for conventional intelligent electronic devices. The proposed algorithm implemented in hardware shows high effectiveness, detecting all islanding conditions within 1 s, sharing the same good performance verified by computational simulations. The algorithm implementation shows robustness, as it remains blocked for other power grid disturbances, such as frequency variation in the grid utility, massive connection or load relief.

13 August 2018 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
VMVictor Luiz Merlin
Victor Luiz Merlin
RSRicardo Caneloi dos Santos
Ricardo Caneloi dos Santos
SBSimon Le Blond
Simon Le Blond
DCDenis Vinicius Coury
Denis Vinicius Coury
This study presents a method based on an artificial neural network (ANN) for protecting voltage source converters (VSC)‐high‐voltage direct current (HVDC) systems. The proposed method takes advantage of ANNs’ excellent capabilities in pattern recognition and classification. The solution presented here is able to detect a fault condition in the whole HVDC system based only on voltage waveforms measured at the rectifier substation, which is an important advantage over other fault detection methods. For any given fault condition, the faulty zone is identified and then the fault is classified concerning the phases or poles involved. The proposed method is shown to be both robust against false operations and very reliable with respect to fault detection and classification. A large number of simulations were performed and results show the effectiveness of the proposed scheme. Different operational conditions and fault cases were considered to evaluate the proposed algorithm, ensuring excellent performance concerning a wide range of possible situations in VSC‐HVDC systems.

1 May 2019 in Electric Power Systems Research
Verified
Journal Article
Closed access
ASAlex S. Silva
Alex S. Silva
RSRicardo C. Santos
Ricardo C. Santos
JTJulio A. Torres
Julio A. Torres
DCDenis Vinicius Coury
Denis Vinicius Coury

27 February 2019 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
JBJair D. Barbosa
Jair D. Barbosa
RSRicardo C. Santos
Ricardo C. Santos
JRJesus F. A. Romero
Jesus F. A. Romero
PAPatricia T. L. Asano
Patricia T. L. Asano
ANAntonio V. S. Neto
Antonio V. S. Neto
PCPaulo Sérgio Cugnasca
Paulo Sérgio Cugnasca

6 January 2014 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
VMVictor Luiz Merlin
Victor Luiz Merlin
RSRicardo Caneloi dos Santos
Ricardo Caneloi dos Santos
APAhda Pionkoski Grilo Pavani
Ahda Pionkoski Grilo Pavani
DCDenis Vinicius Coury
Denis Vinicius Coury
MOMario Oleskovicz
Mario Oleskovicz
JVJose Carlos de Melo Vieira
Jose Carlos de Melo Vieira