The energy and spectrum of the reflected 248 nm radiation are studied from solid targets up to 1.15 × 10 18 W cm −2 intensity. The experiments used the 700 fs directly amplified pulses of the KrF system which was cleaned from prepulses with the new Fourier-filtering method providing 12 orders of magnitude temporal contrast. Increasing the intensity from 10 15 W cm −2 results in increasing absorption up to more than 90% above 10 18 W cm −2 . This is accompanied by increasing x-ray conversion exhibiting a less steep power law dependence for low-Z matter than for gold. Strong blue shift of the reflected radiation from the backward propagating plasma was observed. It is shown that in the case of KrF laser pulses of highest contrast, vacuum heating can be one of the dominant absorption mechanisms. This article is part of a discussion meeting issue ‘Prospects for high gain inertial fusion energy (part 1)’.
Temporal cleaning of high-power infrared (IR) pulses generated by a Ti:Sapphire system is demonstrated by the use of the Nonlinear Fourier Filtering (NFF) method. In a proof-of-principle experiment suppression of up to 1000 is achieved for the temporal pedestal prior to the main pulse, with a moderate (20-25%) overall throughput. This includes the same suppression ratio for the picosecond coherent pedestal in the direct vicinity of the main pulse. Based on the instantaneous, intensity-dependent and high-order switching characteristics of NFF, excellent pulse cleaning performance is observed. The efficient, high-contrast removal of the coherent pedestal from the foot of the main pulse even if its duration is shorter than 100 fs is compared with the capability of the plasma mirror technique. Calculations are also performed, supporting the experimentally observed sharp intensity dependence of the switching process, pointing out the dominant role of the ionization-based refractive index change.
A recently published scheme for inertial fusion based on instantaneous heating of an uncompressed fuel is criticized. It is shown that efficient fusion and “time-like” fusion burn propagation cannot be realized due to the low nuclear reaction cross-sections. The suggested use of nanospheres inside the volume of the target to support the fast heating of the fuel is also questioned.
In high-brightness excimer systems, the direct amplification of short pulses allows temporal filters to be integral parts of the ultraviolet (UV) amplifier chain, where the only origin of the noise is the amplified spontaneous emission (ASE), generated by the amplifier(s) following the filter. The ASE, however, develops faster than the short main pulse; in this paper, the dynamic short- and long-pulse amplification properties of KrF, XeCl and XeF excimers are studied, with special emphasis on the temporal contrast. It was found that, beyond the saturation of amplification, the relaxation of the B state in KrF, together with the contribution of the absorption of the transiently populated X state in XeCl and XeF, are the main limitations for both the extraction efficiency and the contrast. For all excimers, the stimulated transition rates and the dependence of the achievable contrast on the level of saturation were derived. Local quantities were introduced to characterize the deterioration of the contrast for a unit gain length of KrF amplifiers. A KrF power amplifier of limited gain (G ≈ 3), following the newly introduced nonlinear Fourier filter, is capable of reaching contrast levels beyond the previously reported 1011–1012.
The present work demonstrates the performance of a von Hámos high-energy-resolution X-ray spectrometer based on a non-conventional conical Si single-crystal analyzer. The analyzer is tested with different primary and secondary X-ray sources as well as a hard X-ray sensitive CCD camera. The spectrometer setup is also characterized with ray-tracing simulations. Both experimental and simulated results affirm that the conical spectrometer can efficiently detect and resolve the two pairs of two elements (Ni and Cu) Kα X-ray emission spectroscopy (XES) peaks simultaneously, requiring a less than 2 cm-wide array on a single position-sensitive detector. The possible applications of this simple yet broad-energy-spectrum crystal spectrometer range from quickly adapting it as another probe for complex experiments at synchrotron beamlines to analyzing X-ray emission from plasma generated by ultrashort laser pulses at modern laser facilities.