Jonas Schwer

Jonas Schwer

Auto-generated profile, based on publicly available information

Jonas Schwer

Institute of Orthopedic Research and Biomechanics, Center for Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2023 in Acta Biomaterialia
Verified
Journal Article
Open access
JSJonas Schwer
Jonas Schwer
AIAnita Ignatius
Anita Ignatius
ASAndreas Martin Seitz
Andreas Martin Seitz
Biomechanical characterization of meniscal tissue ex vivo remains a critical need, particularly for the development of suitable meniscus replacements or therapeutic strategies that target the native mechanical properties of the meniscus. To date, a huge variety of test configurations and protocols have been reported, making it extremely difficult to compare the respective outcome parameters, thereby leading to misinterpretation. Therefore, the purpose of this systematic review was to identify test-specific parameters that contribute to uncertainties in the determination of mechanical properties of the human meniscus and its attachments, which derived from common quasi-static and dynamic tests in tension, compression, and shear. Strong evidence was found that the determined biomechanical properties vary significantly depending on the specific test parameters, as indicated by up to tenfold differences in both tensile and compressive properties. Test mode (stress relaxation, creep, cyclic) and configuration (unconfined, confined, in-situ), specimen shape and dimensions, preconditioning regimes, loading rates, post-processing of experimental data, and specimen age and degeneration were identified as the most critical parameters influencing the outcome measures. In conclusion, this work highlights an unmet need for standardization and reporting guidelines to facilitate comparability and may prove beneficial for evaluating the mechanical properties of novel meniscus constructs. STATEMENT OF SIGNIFICANCE: The biomechanical properties of the human meniscus have been studied extensively over the past decades. However, it remains unclear to what extent both test protocol and specimen-related differences are responsible for the enormous variability in material properties. Therefore, this systematic review analyzes the biomechanical properties of the human meniscus in the context of the underlying testing protocol. The most sensitive parameters affecting the determination of mechanical properties were identified and critically discussed. Currently, it is of utmost importance for scientists evaluating potential meniscal scaffolds and biomaterials to have a control group rather than a direct comparison to the literature. Standardization of both test procedures and reporting requirements is needed to improve and accelerate the development of meniscal replacement constructs.

18 October 2024 in Acta Biomaterialia
Verified
Journal Article
Open access
LRLuisa de Roy
Luisa de Roy
Graciosa Q. TeixeiraGraciosa Q. Teixeira
Graciosa Q. Teixeira
JSJonas Schwer
Jonas Schwer
MSMatthias Sukopp
Matthias Sukopp
MFMartin Faschingbauer
Martin Faschingbauer
ASAndreas Martin Seitz
Andreas Martin Seitz
Healthy articular cartilage is characterized by extremely low friction and high compressive stiffness. This dual-functionality is tailored by its biphasic structure, whereby a fluid phase interacts with the extracellular matrix. Osteoarthritis (OA) causes structural changes, thereby altering the biomechanical and frictional properties. How the structural and functional properties of human cartilage are associated with OA remain unknown. To address this, we identified relationships between structural parameters, viscoelastic and frictional properties of degenerated human cartilage through correlation analyses. We found that cartilage friction was mainly influenced by its microscopic structure, while the viscoelastic properties were also related to the macroscopic structure. The viscoelastic and frictional properties displayed a weak correlation. These findings provide insights into the interplay between cartilage structure and its functional properties in OA, which might provide a basis for advancements in diagnosing and treating degenerated human cartilage. STATEMENT OF SIGNIFICANCE: : Osteoarthritis causes changes in the cartilages biphasic structure, thereby affecting functionality by altered biomechanical and frictional properties. Currently a cartilage-preserving therapeutic option remains lacking, because the disease is not fully understood. In our correlation analyses, we investigated relationships between the structural, the viscoelastic and frictional properties of degenerated human cartilage. We found that cartilage friction was particularly dependent on the microscopic structure, while the viscoelastic properties also correlated with the macroscopic structure. The frictional properties displayed only a weak dependency with the viscoelastic properties. These new insights into the structure-function and inter-functional relationships may provide new options to advance the diagnosis and treatment of degenerated cartilage.

18 July 2024 in Bone & Joint Open
Verified
Journal Article
Open access
PDF file
MFMartin Faschingbauer
Martin Faschingbauer
JHJakob Hambrecht
Jakob Hambrecht
JSJonas Schwer
Jonas Schwer
JMJohn R. Martin
John R. Martin
HRHeiko Reichel
Heiko Reichel
ASAndreas Seitz
Andreas Seitz
Aims: Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))?Methods: Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined.Results: No statistically significant differences were found regarding coronal alignment (p = 0.087 to p = 0.832). The medial congruent insert demonstrated restricted femoral roll back (mean medial 37.57 mm; lateral 36.34 mm), while the CR insert demonstrated the greatest roll back (medial 42.21 mm; lateral 37.88 mm; p < 0.001, respectively). Femorotibial rotation was greatest with the CR insert with 2.45° (SD 4.75°), then the UC insert with 1.31° (SD 4.15°; p < 0.001), and lowest with the medial congruent insert with 0.8° (SD 4.24°; p < 0.001). The most pronounced patella shift, but lowest patellar rotation, was noted with the CR insert.Conclusion: The MC insert demonstrated the highest level of constraint of these inserts. Femoral roll back, femorotibial rotation, and single bony rotations were lowest with the MC insert. The patella showed less shifting with the MC insert, but there was significantly increased rotation. While the medial congruent insert was found to have highest constraint, it remains uncertain if this implant recreates native knee kinematics or if this will result in improved patient satisfaction.Cite this article: Bone Jt Open 2024;5(7):592–600.

12 September 2025 in Osteoarthritis and Cartilage
Verified
Journal Article
Open access
JSJonas Schwer
Jonas Schwer
MGMichael Gross
Michael Gross
MAMaria Ahrens
Maria Ahrens
LRLuisa de Roy
Luisa de Roy
BMBenjamin Mayer
Benjamin Mayer
Graciosa Q. TeixeiraGraciosa Q. Teixeira
Graciosa Q. Teixeira
To investigate whether alterations in the structure-function relationship of osteoarthritic menisci are associated with the production of catabolic and inflammatory mediators, including the terminal complement complex (C5b-9). Twenty-four human knee joint menisci were equally assigned to mild and severe degeneration groups. Tissue explants underwent pull-to-failure and stress-relaxation testing. Biochemical assays quantified DNA, sulfated glycosaminoglycan (sGAG), and collagen content. Immunohistochemistry assessed collagen types I/II, aggrecan, matrix metalloproteinase (MMP)-3, interleukin (IL)-6, C5b-9, and vascular endothelial growth factor production. Spearman correlation coefficients (SCCs) were calculated to investigate associations between outcome measures. Degeneration-associated changes were mainly observed in medial menisci. Elastic modulus and tensile strength were significantly lower in severely compared to mildly degenerated specimens (mean difference: 13.39 [95% CI: 2.38, 24.40] MPa and 2.54 [0.60, 4.49] MPa, respectively). Degeneration significantly increased permeability (-10.17 [-15.20, -5.20] ×10-15m4/Ns) and sGAG (-16.57 [-30.90, -2.19]), whereas collagen decreased by 116.00 [51.20, 181.00], without affecting collagen types I/II. Severely degenerated menisci produced more MMP-3 (-12.70 [-22.70, -2.70]), IL-6 (-7.76 [-14.16, -1.37]), and C5b-9 (-12.47 [-20.70, -4.25]) than mildly degenerated specimens. In mild degeneration, collagen correlated positively with failure strain (SCC 0.72 [0.25, 0.92]) but became a negative association in the severe degeneration group (SCC -0.37 [-0.81, 0.34]). Correlation analyses between functional, structural, and inflammation-related parameters revealed distinct meniscal phenotypes associated with degeneration severity. Positive correlations in mildly degenerated menisci shifted to negative correlations in severely degenerated specimen (and vice versa), highlighting the complexity of meniscal degeneration during osteoarthritis progression.

8 November 2025 in Osteoarthritis and Cartilage
Verified
Journal Article
Open access
LRLuisa de Roy
Luisa de Roy
KAKonstantin Ambros
Konstantin Ambros
Graciosa Q. TeixeiraGraciosa Q. Teixeira
Graciosa Q. Teixeira
JBJasmin Maria Bülow
Jasmin Maria Bülow
JSJonas Schwer
Jonas Schwer
ASAndreas Martin Seitz
Andreas Martin Seitz
To better understand how patient-specific alterations in the synovial fluid composition and its viscosity affect cartilage friction of samples with mild and advanced signs of degeneration. Synovial fluid, mild and advanced degenerated cartilage samples were collected from twelve patients undergoing knee replacement surgery. Friction tests were performed under simulated gait conditions, with each sample lubricated with its patient-specific synovial fluid. Cartilage degeneration was assessed macroscopically and microscopically. Synovial fluid samples were analyzed for viscosity and biochemical composition and the Spearman method was used to assess relationships between all parameters. Friction of mildly degenerated cartilage samples negatively correlated with the proteoglycan 4 concentration in the synovial fluid (µendStance: ρ = -0.9, 95% CI [-1.0, -0.8], p < 0.01), µendSwing: ρ = -0.7, 95% CI [-0.9, -0.3], p = 0.01). For advanced degenerated samples, significant positive correlations were found between friction during swing phase of gait (µendSwing) and synovial fluid viscosity values (η0.01(25 °C): ρ = -0.7, 95% CI [-0.9, -0.2], p = 0.01; η1000(25 °C): ρ = -0.8, 95% CI [-0.9, -0.4], p = < 0.01). The impact of SF alterations on AC friction depends on the tissue's degeneration severity. These findings might provide valuable information when selecting appropriate patient populations and timing of treatment options, particularly tribosupplementation approaches, which address the knee joint's tribology.

2 October 2024 in Computers in Biology and Medicine
Verified
Journal Article
Open access
JSJonas Schwer
Jonas Schwer
FGFabio Galbusera
Fabio Galbusera
AIAnita Ignatius
Anita Ignatius
LDLutz Dürselen
Lutz Dürselen
ASAndreas Martin Seitz
Andreas Martin Seitz
Accurate identification of local changes in the biomechanical properties of the normal and degenerative meniscus is critical to better understand knee joint osteoarthritis onset and progression. Ex-vivo material characterization is typically performed on specimens obtained from different locations, compromising the tissue's structural integrity and thus altering its mechanical behavior. Therefore, the aim of this in-silico study was to establish a non-invasive method to determine the region-specific material properties of the degenerated human meniscus. In a previous experimental magnetic resonance imaging (MRI) study, the spatial displacement of the meniscus and its root attachments in mildly degenerated (n = 12) and severely degenerated (n = 12) cadaveric knee joints was determined under controlled subject-specific axial joint loading. To simulate the experimental response of the lateral and medial menisci, individual finite element models were created utilizing a transverse isotropic hyper-poroelastic constitutive material formulation. The superficial displacements were applied to the individual models to calculate the femoral reaction force in an inverse finite element analysis. During particle swarm optimization, the four most sensitive material parameters were varied to minimize the error between the femoral reaction force and the force applied in the MRI loading experiment. Individual global and regional parameter sets were identified. In addition to in-depth model verification, prediction errors were determined to quantify the reliability of the identified parameter sets. Both compressibility of the solid meniscus matrix (+141 %, p ≤ 0.04) and hydraulic permeability (+53 %, p ≤ 0.04) were significantly increased in the menisci of severely degenerated knees compared to mildly degenerated knees, irrespective of the meniscus region. By contrast, tensile and shear properties were unaffected by progressive knee joint degeneration. Overall, the optimization procedure resulted in reliable and robust parameter sets, as evidenced by mean prediction errors of <1 %. In conclusion, the proposed approach demonstrated high potential for application in clinical practice, where it might provide a non-invasive diagnostic tool for the early detection of osteoarthritic changes within the knee joint.