Fernando Antonio Siano dos Reis

Fernando Antonio Siano dos Reis

Auto-generated profile, based on publicly available information

Fernando Antonio Siano dos Reis

Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Endodontia, Brazil

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FRFernando Antonio Siano dos Reis
Fernando Antonio Siano dos Reis
Amjad Abu HasnaAmjad Abu Hasna
Amjad Abu Hasna
GRGustavo Ragozzini
Gustavo Ragozzini
FMFelipe Bernardo de Moura
Felipe Bernardo de Moura
TCTiago Moreira Bastos Campos
Tiago Moreira Bastos Campos
CBCarlos Eduardo Silveira Bueno
Carlos Eduardo Silveira Bueno
This study aimed to evaluate the effect of the number of uses and autoclave sterilization on the cyclic fatigue resistance of four replica-like instruments RC Blue; Only One File Blue; Recip One Blue; and Micro Blue compared to the original system Reciproc Blue (VDW, Munich, Germany). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). Fifty molars were instrumented by ten instruments (n=10). After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more using different molars, totaling 3 rounds of instrumentation, sterilization and SEM analysis. Then, ten different instruments from each brand were tested for cyclic fatigue resistance. Number of uses data were analyzed using Chi-squared analysis, and cyclic fatigue data were analyzed by one-way Anova followed by Tukey’s test as the data had normal distribution. The fracture times for all systems had no significant difference, but Micro Blue had significantly lower values than the other systems (p < 0.05). The SEM analysis showed distortions in the instruments after the 3rd use. Therefore, all tested instruments except of Micro Blue have similar resistance to cyclic fatigue, and all are reliable for use in up to 2-cases.

1 January 2024 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
GRGustavo Ragozzini
Gustavo Ragozzini
Amjad Abu HasnaAmjad Abu Hasna
Amjad Abu Hasna
FRFernando Antonio Siano dos Reis
Fernando Antonio Siano dos Reis
FMFelipe Bernardo de Moura
Felipe Bernardo de Moura
TCTiago Moreira Bastos Campos
Tiago Moreira Bastos Campos
AMAlexandre Sigrist de Martin
Alexandre Sigrist de Martin
This study aimed to evaluate the effect of autoclave sterilization on the integrity and instruments’ fracture number after multiple uses and cyclic fatigue of the original WaveOne Gold (Dentsply Sirona Endodontics) compared to four replica‐like instruments (TF4‐Gold, Roll‐Wave‐Gold, W‐File, and Micro‐Gold). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). One hundred and fifty human molars, freshly extracted for orthodontic reasons or periodontal disease and with severe curvature (between 30° and 60°), were used. Fifty teeth were instrumented with 10 instruments from each group and were evaluated for integrity. After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more, totaling three rounds of instrumentation, sterilization, and SEM analysis. Ten unused instruments from each group were evaluated for resistance to cyclic fatigue in a static test using a motor and a device simulating a canal with a 60° curvature angle. The instruments were driven by the motor until separation, visually verified, and the time measured in seconds. Data were analyzed by Chi‐square, one‐way ANOVA, and Tukey analysis, considering a significance level of 5%. It was found that there was no statistically significant difference between the groups tested in the effect of sterilization on the number of uses. The SEM analysis showed distortions in the instruments after the 3rd use. There was a statistically significant difference in the cyclic fatigue test between the results of WaveOne Gold, TF4 Gold, and Roll Wave Gold compared to W File and Micro Gold (P < 0.0001) and a statistically significant difference between the W File and Micro Gold groups (P < 0.0001). In conclusion, this study affirmed that WaveOne Gold, TF4‐Gold, and Roll‐Wave‐Gold instruments exhibit comparable cyclic fatigue resistance. Besides, all examined instruments can be reliably employed for up to two cases.