This study aimed to evaluate the effect of autoclave sterilization on the integrity and instruments’ fracture number after multiple uses and cyclic fatigue of the original WaveOne Gold (Dentsply Sirona Endodontics) compared to four replica‐like instruments (TF4‐Gold, Roll‐Wave‐Gold, W‐File, and Micro‐Gold). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). One hundred and fifty human molars, freshly extracted for orthodontic reasons or periodontal disease and with severe curvature (between 30° and 60°), were used. Fifty teeth were instrumented with 10 instruments from each group and were evaluated for integrity. After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more, totaling three rounds of instrumentation, sterilization, and SEM analysis. Ten unused instruments from each group were evaluated for resistance to cyclic fatigue in a static test using a motor and a device simulating a canal with a 60° curvature angle. The instruments were driven by the motor until separation, visually verified, and the time measured in seconds. Data were analyzed by Chi‐square, one‐way ANOVA, and Tukey analysis, considering a significance level of 5%. It was found that there was no statistically significant difference between the groups tested in the effect of sterilization on the number of uses. The SEM analysis showed distortions in the instruments after the 3rd use. There was a statistically significant difference in the cyclic fatigue test between the results of WaveOne Gold, TF4 Gold, and Roll Wave Gold compared to W File and Micro Gold (P < 0.0001) and a statistically significant difference between the W File and Micro Gold groups (P < 0.0001). In conclusion, this study affirmed that WaveOne Gold, TF4‐Gold, and Roll‐Wave‐Gold instruments exhibit comparable cyclic fatigue resistance. Besides, all examined instruments can be reliably employed for up to two cases.
Background/Objectives: The restoration of structurally weakened roots remains a clinical challenge. This in vitro study evaluated the fracture resistance, failure pattern, and stress distribution of weakened bovine roots restored with two glass fiber post systems under different remaining root dentin thicknesses. Methods: Sixty bovine incisor roots were divided into six groups (n = 10): G1, 2 mm of remaining root dentin without a post; G2, 3 mm without a post; G3, 2 mm with an Exacto post; G4, 3 mm with an Exacto post; G5, 2 mm with a Splendor-SAP post; and G6, 3 mm with a Splendor-SAP post. Specimens underwent root canal treatment and standardized restoration, followed by 1,200,000 mechanical cycles at 88 N and 3.8 Hz and fracture testing at 45°. Finite element models were subjected to an 88 N oblique load. Fracture resistance was analyzed using Welch’s one-way ANOVA followed by Games–Howell post hoc comparisons, whereas failure patterns were analyzed using the Fisher–Freeman–Halton exact test. Results: Fracture resistance differed significantly among groups (p < 0.001). G1 (88.7 N) and G2 (95.6 N) showed the lowest and statistically similar values; G3 (670.9 N) and G5 (691.9 N) showed intermediate and statistically similar values; and G4 (786.2 N) and G6 (784.8 N) showed the highest and statistically similar values. Failure-pattern distribution was not significantly associated with the experimental groups (p = 0.582). Finite element analysis showed stress concentration predominantly in the cervical region of the root, with G5 showing the highest maximum principal stress in root dentin. Conclusions: Glass fiber posts substantially increased the fracture resistance of weakened roots. Among post-restored specimens, roots with 3 mm of remaining dentin showed higher fracture resistance than those with 2 mm, whereas no significant difference was observed between the Exacto and Splendor-SAP systems under the same remaining-dentin condition.
12 February 2026 in Revista Fluminense de Geografia