11 February 2026 in IEEE Journal of Translational Engineering in Health and Medicine
Objectives: To develop and evaluate a wearable, garment-integrated transcutaneous electrical nerve stimulation (TENS) system for relieving osteoarthritis knee pain, emphasizing safety, usability, and readiness for home and clinical deployment. Methods: We designed an IEC 60601 compliant TENS system that embeds flexible electrodes into a close-fitting, machine-washable textile. A seven-day, home-based usability evaluation was conducted with 11 participants with osteoarthritis. Outcomes included self-reported pain (baseline vs. post-use) and usability metrics (ease of setup and comfort). The system received Medicines and Healthcare products Regulatory Agency (MHRA) and Health Research Authority (HRA) approvals for a subsequent clinical investigation. Results: Participants reported strong user acceptance, ease of use and comfort. Average pain decreased by 54.79% over the evaluation period, indicating a meaningful short-term analgesic benefit in a home setting. No serious adverse events were observed. Conclusion: Integrating electrodes into a wearable garment addresses key limitations of conventional adhesive-pad TENS, improving placement consistency, comfort, and ease of use while supporting safe operation under IEC 60601. These preliminary findings support the feasibility of garment-based TENS for osteoarthritis management at home and justify a follow-on clinical trial to rigorously quantify pain relief, functional outcomes, and user satisfaction in a larger cohort. Clinical impact: The use of a washable TENS garment, compliant with IEC 60601, resulted in reduced osteoarthritis pain in a home setting. Its integration into home care is facilitated by an easy to use device with reusable textile electrodes.
10 December 2024 in JMIR Biomedical Engineering
Background: Long-term unobtrusive monitoring of breathing patterns can potentially give a more realistic insight into the respiratory health of people with asthma or chronic obstructive pulmonary disease than brief tests performed in medical environments. However, it is uncertain whether users would be willing to wear these sensor garments long term. Objective: Our objective was to explore whether users would wear ordinary looking knitted garments with unobtrusive knitted-in breathing sensors long term to monitor their lung health and under what conditions. Methods: Multiple knitted breathing sensor garments, developed and fabricated by the research team, were presented during a demonstration. Participants were encouraged to touch and feel the garments and ask questions. This was followed by two semistructured, independently led focus groups with a total of 16 adults, of whom 4 had asthma. The focus group conversations were recorded and transcribed. Thematic analysis was carried out by three independent researchers in 3 phases consisting of familiarization with the data, independent coding, and overarching theme definition. Participants also completed a web-based questionnaire to probe opinion about wearability and functionality of the garments. Quantitative analysis of the sensors’ performance was mapped to participants’ garment preference to support the feasibility of the technology for long-term wear. Results: Key points extracted from the qualitative data were (1) garments are more likely to be worn if medically prescribed, (2) a cotton vest worn as underwear was preferred, and (3) a breathing crisis warning system was seen as a promising application. The qualitative analysis showed a preference for a loose-fitting garment style with short sleeves (13/16 participants), 11 out of 16 would also wear snug fitting garments and none of the participants would wear tight-fitting garments over a long period of time. In total, 10 out of 16 participants would wear the snug fitting knitted garment for the whole day and 13 out of 16 would be happy to wear it only during the night if not too hot. The sensitivity demands on the knitted wearable sensors can be aligned with most users’ garment preferences (snug fit). Conclusions: There is an overall positive opinion about wearing a knitted sensor garment over a long period of time for monitoring respiratory health. The knit cannot be tight but a snugly fitted vest as underwear in a breathable material is acceptable for most participants. These requirements can be fulfilled with the proposed garments. Participants with asthma supported using it as a sensor garment connected to an asthma attack alert system.
8 March 2024 in JMIR Preprints
BACKGROUND Long-term unobtrusive monitoring of breathing patterns can potentially give a more realistic insight into the respiratory health of people with asthma or chronic obstructive pulmonary disease than brief tests performed in medical environments. However, it is uncertain whether users would be willing to wear these sensor garments long term. OBJECTIVE Our objective was to explore whether users would wear ordinary looking knitted garments with unobtrusive knitted-in breathing sensors long term to monitor their lung health and under what conditions. METHODS Multiple knitted breathing sensor garments, developed and fabricated by the research team, were presented during a demonstration. Participants were encouraged to touch and feel the garments and ask questions. This was followed by two semistructured, independently led focus groups with a total of 16 adults, of whom 4 had asthma. The focus group conversations were recorded and transcribed. Thematic analysis was carried out by three independent researchers in 3 phases consisting of familiarization with the data, independent coding, and overarching theme definition. Participants also completed a web-based questionnaire to probe opinion about wearability and functionality of the garments. Quantitative analysis of the sensors’ performance was mapped to participants’ garment preference to support the feasibility of the technology for long-term wear. RESULTS Key points extracted from the qualitative data were (1) garments are more likely to be worn if medically prescribed, (2) a cotton vest worn as underwear was preferred, and (3) a breathing crisis warning system was seen as a promising application. The qualitative analysis showed a preference for a loose-fitting garment style with short sleeves (13/16 participants), 11 out of 16 would also wear snug fitting garments and none of the participants would wear tight-fitting garments over a long period of time. In total, 10 out of 16 participants would wear the snug fitting knitted garment for the whole day and 13 out of 16 would be happy to wear it only during the night if not too hot. The sensitivity demands on the knitted wearable sensors can be aligned with most users’ garment preferences (snug fit). CONCLUSIONS There is an overall positive opinion about wearing a knitted sensor garment over a long period of time for monitoring respiratory health. The knit cannot be tight but a snugly fitted vest as underwear in a breathable material is acceptable for most participants. These requirements can be fulfilled with the proposed garments. Participants with asthma supported using it as a sensor garment connected to an asthma attack alert system.
11 June 2026 in Small Structures
Knee osteoarthritis (OA) is a common musculoskeletal condition associated with chronic pain and reduced mobility. This paper presents the co‐design and development of a wearable e‐textile garment, created in collaboration with eight healthcare professionals and ten individuals with knee OA, to support non‐pharmacological pain management and muscle exercise. The garment integrates embedded dry electrodes that deliver transcutaneous electrical nerve stimulation for knee pain relief and neuromuscular electrical stimulation to strengthen the quadriceps and hamstrings, thereby further supporting the knee joint. Development activities included focus groups, interviews, e‐garment design and fabrication, and lab‐based fitting and testing sessions to iteratively refine garment design, sizing, and electrode positioning. Initial testing provided early indications of safety, usability, durability, and functional performance. This research demonstrates the potential of e‐textile‐based wearable healthcare devices in the management of knee OA and lays the foundation for further home usability testing and clinical evaluation.