27 May 2022 in IEEE Transactions on Electromagnetic Compatibility
Spring contacts are used in mobile communication devices to connect metal planes near the antennas. Inappropriate design of the spring contacts will cause harmonic generation at the contact which can deteriorate receiver sensitivity at the harmonic frequency. In this article, the passive radio frequency (RF) harmonic generation phenomenon on spring contacts is studied. A spring contact harmonic generation measurement system is developed. The measurement system comprises of spring contact test vehicle, force sensor, xyz-stage with step motors, and RF path. The factors that may have an impact on the spring contact harmonic generation, such as contact material, contact force, and contact resistance are investigated. It is found that the overall harmonics generated at the spring contact decreased as the contact force increased. The gold-to-gold contact is found to be superior to the stainless-steel contacts. Indications are found that the nonlinearity at the stainless-steel spring contact is the combination of metal-insulator-metal junctions and p-n junctions formed by the surface oxide layer on the stainless steel. Recommendations to reduce the harmonic generation are discussed.
27 June 2023 in IEEE Transactions on Instrumentation and Measurement
This paper presents a novel peak detect and hold (PDH) circuit for the measurement of the peak voltage of electromagnetic-field probes. These probes are used to capture the fields generated by electrostatic discharge (ESD) events in non-grounded portable devices. Therefore, a circuit combining small size, low power consumption and nano-second operation is needed. A topology using a discrete bipolar transistor structure with OTA and common-base storage capacitor charge control optimally meets the requirements. The circuit performance is demonstrated for different bias point settings. The error between the captured value and the actual pulse peak value is shown as a function of rise time, pulse length, amplitude and bias settings. A comparison with literature, shows unmatched performance with respect to speed and power consumption. Using the bias settings the PDH circuit can be adjusted to the sensor’s frequency response to minimize power consumption in a multi-channel system containing sensors of different bandwidth.
13 November 2025 in IEEE Transactions on Electromagnetic Compatibility
An electrostatic discharge (ESD) to the glass of a touchscreen display can damage capacitive touch sensor circuitry and traces. The ESD creates a sparkless corona discharge on the glass surface, which couples to sense patches on the other side of the glass. Currents induced on sense traces during the corona discharge are measured in an evaluation setup, which resembles the touchscreen design. Waveforms for current induced at different distances from the discharge position are recorded and compared. The induced currents are analyzed by their peak value and the total charge or energy delivered to the sense trace for different discharge polarities and voltage levels and for 20 different touchscreen configurations. Trends in the dissipated energy were found as a function of the glass thickness, the capacitance from the sense patch to reference ground, and the resistance of the sense trace. A simulation model to estimate coupling to touchscreen circuitry was developed by representing the ionized corona as concentric rings on the glass surface centered at the discharge location. Using a circuit model and data measured experimentally, the current source waveforms for different rings can be found and used in full-wave simulations to excite the rings and predict the current coupled to the sensor patches. This methodology can be used for a variety of touchscreen designs that are similar to those measured to explore the impact of design changes on ESD immunity.